Monte Carlo simulation of the effect of magnetic fields on brachytherapy dose distributions in lung tissue material

被引:3
|
作者
Moreno-Barbosa, Fernando [1 ]
de Celis-Alonso, Benito [1 ]
Moreno-Barbosa, Eduardo [1 ]
Hernandez-Lopez, Javier Miguel [1 ]
Geoghegan, Theodore [2 ]
Ramos-Mendez, Jose [3 ]
机构
[1] Benemerita Univ Autonoma Puebla, Fac Math & Phys Sci, Mexico City, DF, Mexico
[2] Univ Iowa Hosp & Clin, Dept Radiat Oncol, Iowa City, IA 52242 USA
[3] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
来源
PLOS ONE | 2020年 / 15卷 / 10期
关键词
MV RADIOTHERAPY ACCELERATOR; MRI SCANNER; ELECTRON; DOSIMETRY; ALGORITHM; TOMOGRAPHY; DEPOSITION; GEANT4; TOPAS;
D O I
10.1371/journal.pone.0238704
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this work was to use TOPAS Monte Carlo simulations to model the effect of magnetic fields on dose distributions in brachytherapy lung treatments, under ideal and clinical conditions. Idealistic studies were modeled consisting of either a monoenergetic electron source of 432 keV, or a polyenergetic electron source using the spectrum of secondary electrons produced by(192)Ir gamma-ray irradiation. The electron source was positioned in the center of a homogeneous, lung tissue phantom (rho = 0.26 g/cm(3)). Conversely, the clinical study was simulated using the VariSource VS2000 Ir-192 source in a patient with a lung tumor. Three contoured volumes were considered: the tumor, the planning tumor volume (PTV), and the lung. In all studies, dose distributions were calculated in the presence or absence of a constant magnetic field of 3T. Also, TG-43 parameters were calculated for the VariSource and compared with published data from EGS-brachy (EGSnrc) and PENELOPE. The magnetic field affected the dose distributions in the idealistic studies. For the monoenergetic and poly-energetic studies, the radial distance of the 10% iso-dose line was reduced in the presence of the magnetic field by 64.9% and 24.6%, respectively. For the clinical study, the magnetic field caused differences of 10% on average in the patient dose distributions. Nevertheless, differences in dose-volume histograms were below 2%. Finally, for TG-43 parameters, the dose-rate constant from TOPAS differed by 0.09% +/- 0.33% and 0.18% +/- 0.33% with respect to EGS-brachy and PENELOPE, respectively. The geometry and anisotropy functions differed within 1.2% +/- 1.1%, and within 0.0% +/- 0.3%, respectively. The Lorentz forces inside a 3T magnetic resonance machine during(192)Ir brachytherapy treatment of the lung are not large enough to affect the tumor dose distributions significantly, as expected. Nevertheless, large local differences were found in the lung tissue. Applications of this effect are therefore limited by the fact that meaningful differences appeared only in regions containing air, which is not abundant inside the human.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Dose modification factor analysis of multilumen balloon brachytherapy applicator with Monte Carlo simulation
    Pearson, David
    Williams, Eric A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 54 - 62
  • [32] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Weiss, DE
    Johnson, WC
    Kensek, RP
    RADIATION PHYSICS AND CHEMISTRY, 1997, 50 (05): : 475 - 485
  • [33] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Corp. Res. Proc. Technol. Laboratory, 3M Company, 3M Center, St. Paul, MN 55144-1000, United States
    不详
    不详
    Radiat. Phys. Chem., 5 (475-485):
  • [34] Investigation of Micron-Scale Radiotherapy Dose Deposition in the Lung: Effect of Magnetic Field and Nanoparticles-a Monte Carlo Simulation
    Montinola, Denxybel
    McNamara, Aimee L.
    Kuncic, Zdenka
    Byrne, Hilary L.
    FRONTIERS IN PHYSICS, 2022, 10
  • [35] Monte Carlo Study on Dose Enhancement Effect of Various Paramagnetic Nanoshells in Brachytherapy
    Moghaddas, Toktam Ahmadi
    Ghorbani, Mandi
    Haghparast, Abbas
    Flynn, Ryan Thomas
    Eivazi, Mohammad Taghi
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (06) : 559 - 567
  • [36] Assessment of absorbed dose in deformed breast tissue by Monte Carlo simulation
    Ashoor, Mansour
    Khorshidi, Abdollah
    SN APPLIED SCIENCES, 2020, 2 (08):
  • [37] Assessment of absorbed dose in deformed breast tissue by Monte Carlo simulation
    Mansour Ashoor
    Abdollah Khorshidi
    SN Applied Sciences, 2020, 2
  • [38] Monte Carlo simulation of oil fields
    Kok, Mustafa Versan
    Kaya, Egemen
    Akin, Serhat
    ENERGY SOURCES PART B-ECONOMICS PLANNING AND POLICY, 2006, 1 (02) : 207 - 211
  • [39] An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions
    Rivard, Mark J.
    Melhus, Christopher S.
    Granero, Domingo
    Perez-Calatayud, Jose
    Ballester, Facundo
    MEDICAL PHYSICS, 2009, 36 (06) : 1968 - 1975
  • [40] A Monte Carlo Study for Evaluation of Tissue Heterogeneity Effect of Inversely Optimized Intracavitary High Dose Rate Brachytherapy Plan
    Cheong, K.
    Lee, M.
    Kang, S.
    Park, S.
    Kim, K.
    Hwang, T.
    Bae, H.
    Oh, D.
    Suh, T.