FRICKE GEL DOSIMETERS FOR THE MEASUREMENT OF THE ANISOTROPY FUNCTION OF A HDR IR-192 BRACHYTHERAPY SOURCE

被引:0
|
作者
Carrara, M. [1 ]
Tomatis, S. [1 ]
Zonca, G. [1 ]
Gambarini, G. [2 ,3 ]
Bartesaghi, G. [2 ,3 ]
Tenconi, C. [2 ]
Cerrotta, A. [4 ]
Fallai, C. [4 ]
机构
[1] Fdn IRCCS, Ist Nazl Tumori, Med Phys Unit, I-20133 Milan, Italy
[2] Univ Milan, Dept Phys, Via Celoria 16, I-20133 Milan, Italy
[3] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[4] Fdn IRCCS, Ist Nazl Tumori, Radiotherapy Unit, I-20133 Milan, Italy
关键词
D O I
10.1142/9789814307529_0100
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The anisotropy function F(r,theta) has been recommended to account for the dose distribution anisotropy that results adopting sealed brachytherapy sources. This function is implemented in the American Association of Physicists in Medicine (AAPM) dose calculation formalism and is widely adopted by the currently available treatment planning systems. In this work, a method based on a suitably developed Fricke gel dosimeter with a built-in catheter and on an optical imaging system was developed for the characterization of F(r,theta) for an Ir-192 source. At radial distances of 15, 20, 25 and 30 mm percentage differences between tabulated and measured data resulted to be almost always smaller than 3%. Fricke gel dosimeters result to be accurate tools for the Ir-192 anisotropy function measurement. These instruments could be easily adopted in quality assurance protocolls to verify the anisotropy function of each newly installed Ir-192 source.
引用
收藏
页码:610 / 614
页数:5
相关论文
共 50 条
  • [11] Determination of contributions of scatter and distance error to the source strength of Ir-192 HDR brachytherapy source
    BONDEL, Shwetha
    RAVIKUMAR, Manickam
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2016, 22 (03) : 55 - 59
  • [12] A Study on the Dose Distributions in Various Materials from an Ir-192 HDR Brachytherapy Source
    Hsu, Shih-Ming
    Wu, Chin-Hui
    Lee, Jeng-Hung
    Hsieh, Ya-Ju
    Yu, Chun-Yen
    Liao, Yi-Jen
    Kuo, Li-Cheng
    Liang, Ji-An
    Huang, David Y. C.
    PLOS ONE, 2012, 7 (09):
  • [13] Development of An Absorbed Dose to Water Primary Standard for HDR Ir-192 Brachytherapy Based On the Fricke Dosimetry System
    El Gamal, I.
    Cojocaru, C.
    Mainegra-Hing, E.
    Ross, C.
    McEwen, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [14] 3D Dosimetric Verification of Ir-192 HDR Brachytherapy Source Irradiation
    Pierquet, M.
    Oldham, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [15] Response of the alanine/ESR dosimeter to radiation from an Ir-192 HDR brachytherapy source
    Anton, M.
    Hackel, T.
    Zink, K.
    von Voigts-Rhetz, P.
    Selbach, H-J
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01): : 175 - 193
  • [16] Ir-192 Calibration in Air with Farmer Chamber for HDR Brachytherapy
    Liyun Chang
    Sheng-Yow Ho
    Tsair-Fwu Lee
    Hueisch-Jy Ding
    Pang-Yu Chen
    Journal of Medical and Biological Engineering, 2016, 36 : 145 - 152
  • [17] Ir-192 Calibration in Air with Farmer Chamber for HDR Brachytherapy
    Chang, Liyun
    Ho, Sheng-Yow
    Lee, Tsair-Fwu
    Ding, Hueisch-Jy
    Chen, Pang-Yu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (02) : 145 - 152
  • [18] The Fricke dosimeter as an absorbed dose to water primary standard for Ir-192 brachytherapy
    El Gamal, Islam
    Cojocaru, Claudiu
    Mainegra-Hing, Ernesto
    McEwen, Malcolm
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (11): : 4481 - 4495
  • [19] Dosimetry for Ir-192 HDR Brachytherapy - Present Status and Future Direction
    DeWerd, L.
    Seuntjens, J.
    Rivard, M.
    McEwen, M.
    MEDICAL PHYSICS, 2012, 39 (06) : 3884 - 3885
  • [20] Monte Carlo study of a bunker used for HDR Ir-192 brachytherapy
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Puchades, V
    Casal, E
    Crispin, V
    Cases, R
    Agramunt, S
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S242 - S242