Application and development of industrial computed tomography in China

被引:0
|
作者
Kong, FG
Xian, W
机构
关键词
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Compared with traditional perspective radiography, ICT (Industrial Computed Tomography) is able to acquire tomography image without the disadvantages of image overlapping and blurring that exist in traditional perspective radiography. By acquiring the 2D tomography image of the object at different stage as many as needed, it is possible to achieve 3D tomography image. In China, the first Gamma-ray ICT equipment was born at Chongqing University in May 1993. For this equipment, Co-60 radiation source with 1 Ci and 30 Ci was used, and spatial resolution is about 0.5mm, and density resolution is about 0.5%, and the diameter of the test object can be 300mm, but the price of the Chinese ICT equipment is only about a half on the same type of ICT equipment producing abroad other than China. Besides Gamma-ray ICT, Chinese are engaging in research and develop X-ray ICT to meet foreign and domestic need.
引用
收藏
页码:1447 / 1450
页数:4
相关论文
共 50 条
  • [1] Technical property and application of industrial computed tomography
    Sun, Ling-Xia
    Ye, Yun-Chang
    [J]. Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2006, 26 (04): : 486 - 488
  • [2] INDUSTRIAL APPLICATION OF COMPUTED-TOMOGRAPHY TECHNIQUES
    IZUMI, S
    KANAMORI, T
    KAWASAKI, S
    FUJII, M
    FUJINE, S
    [J]. JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1988, 30 (01): : 2 - 8
  • [3] APPLICATION OF COMPUTED AXIAL TOMOGRAPHY TO INDUSTRIAL RADIOGRAPHY
    KRUGER, RP
    CANNON, TM
    [J]. MATERIALS EVALUATION, 1977, 35 (06) : 21 - 21
  • [4] Computed Tomography Metrology in Industrial Research and Development
    Kasperl, Stefan
    Hiller, Jochen
    Krumm, Michael
    [J]. MATERIALS TESTING-MATERIALS AND COMPONENTS TECHNOLOGY AND APPLICATION, 2009, 51 (06): : 405 - 411
  • [5] DEVELOPMENT OF INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY AND ITS APPLICATION TO REFRACTORIES
    AIBA, Y
    OKI, K
    NAKAMURA, S
    FUJII, M
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 (14): : 1692 - 1699
  • [6] DEVELOPMENT OF INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY AND ITS APPLICATION TO REFRACTORIES
    AIBA, Y
    OKI, K
    MATSUURA, S
    FUJII, M
    [J]. TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 26 (03) : 236 - 243
  • [7] Application of industrial 3D computed tomography
    Maisl, M
    Reiter, H
    Purschke, M
    Zabler, E
    Rosenberger-Koch, M
    [J]. METALL, 2001, 55 (06): : 368 - 371
  • [8] Iterative reconstruction techniques for industrial computed tomography: Application and performance
    Arrowood, L.
    Gregor, J.
    Bingham, P.
    [J]. MATERIALS EVALUATION, 2007, 65 (11) : 1109 - 1112
  • [9] Industrial computed tomography system for aerospace applications: development and characterisation
    Reddy, M. V.
    Lukose, S. N.
    Subramanian, M. P.
    Rao, G. V. Siva
    Muralidhar, C.
    Balasubramaniam, K.
    [J]. INSIGHT, 2011, 53 (06) : 307 - 311
  • [10] Development of industrial single photon emission computed tomography (ISPECT)
    Ithnin, Hanafi
    Mohamad, Elmy Johana
    Yusoff, Nazrul Hizam
    Hassan, Hearie
    Lip, Norliana Mohd
    [J]. INTERNATIONAL NUCLEAR SCIENCE TECHNOLOGY AND ENGINEERING CONFERENCE 2019 (INUSTEC2019), 2020, 785