Sterilization effectiveness of in-duct ultraviolet germicidal irradiation system in liquid desiccant and indirect/direct evaporative cooling-assisted 100% outdoor air system

被引:20
|
作者
Bang, Jong-Il [1 ]
Park, Joon-Young [2 ]
Jo, Ye-Lim [1 ]
Jeong, Jae-Weon [3 ]
Choi, Anseop [1 ]
Sung, Minki [1 ]
机构
[1] Sejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South Korea
[2] Device Solut, Samsung Elect, Facil Team, 90 Samsung Ro, Pyeongtaek Si 17786, Gyeonggi Do, South Korea
[3] Hanyang Univ, Dept Architectural Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Liquid desiccant and indirect/direct evaporative cooling-assisted 100% Outdoor air system (LD-IDECOAS); In-duct ultraviolet germicidal irradiation (ID-UVGI); Irradiation analysis; Microbial contamination; Indoor air quality; PERFORMANCE; CONTAMINATION; BACTERIA; DISINFECTION;
D O I
10.1016/j.buildenv.2020.107350
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Microorganism contamination in air conditioning systems can cause respiratory diseases in building occupants. This study aims to evaluate and predict the performance of an in-duct ultraviolet germicidal irradiation (IDUVGI) system to reduce the microorganisms that can grow in the liquid desiccant and indirect/direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS). Bacteria and mold on the direct evaporative cooling (DEC) element and in the outdoor and supply air were monitored using a swab and Petrifilm for surfaces and impact sampler for air during the operation of the LD-IDECOAS. Microbial contamination was first verified in the air before performing the sterilization experiment. The experimental results showed that the airborne bacteria were reduced by 78.3% after the operation of the ID-UVGI system but there was almost no reduction in the airborne mold. The bacteria and mold concentration on the DEC surface were decreased by 99.7% and 96.7% respectively 3 h after the ID-UVGI operation. Even after the ID-UVGI system was operated for 6 days, the microbial contamination in the downstream water was not decreased significantly; the inside of the DEC element was suspected to be improperly sterilized. The operating times of the ID-UVGI system needed to inactivate the microorganisms were predicted from the UV-C intensity distribution by irradiation analysis. Legionella sp. and Penicillium sp. were predicted to be inactivated by 99.9% with UV-C exposures of 6 s and 15 min 57 s or less respectively when the LD-IDECOAS is operated at the highest air flow rate.
引用
收藏
页数:11
相关论文
共 22 条
  • [1] Energy Performance of a Liquid Desiccant and Evaporative Cooling-Assisted 100% Outdoor Air System in Commercial Ships
    Park, Joon-Young
    Lee, Sung-Joon
    Yoon, Dong-Seob
    Jeong, Jae-Weon
    2016 ASHRAE ANNUAL CONFERENCE PAPERS, 2016,
  • [2] Operating energy savings in a liquid desiccant and dew point evaporative cooling-assisted 100% outdoor air system
    Ham, Sang-Woo
    Lee, Sung-Joon
    Jeong, Jae-Weon
    ENERGY AND BUILDINGS, 2016, 116 : 535 - 552
  • [3] Retrofit of a liquid desiccant and evaporative cooling-assisted 100% outdoor air system for enhancing energy saving potential
    Kim, Min-Hwi
    Yoon, Dong-Seop
    Kim, Hui-Jeong
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2016, 96 : 441 - 453
  • [4] Energy conservation benefit of water-side free cooling in a liquid desiccant and evaporative cooling-assisted 100% outdoor air system
    Kim, Min-Hwi
    Park, Joon-Young
    Ham, Sang-Woo
    Jeong, Jae-Weon
    ENERGY AND BUILDINGS, 2015, 104 : 302 - 315
  • [5] Primary energy savings in desiccant and evaporative cooling-assisted 100% outdoor air system combined with a fuel cell
    Kim, Min-Hwi
    Dong, Hae-Won
    Park, Joon-Young
    Jeong, Jae-Weon
    APPLIED ENERGY, 2016, 180 : 446 - 456
  • [6] Application of desiccant systems for improving the performance of an evaporative cooling-assisted 100% outdoor air system in hot and humid climates
    Kim, Min-Hwi
    Park, Joon-Young
    Park, Jun-Seok
    Jeong, Jae-Weon
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2015, 8 (03) : 173 - 190
  • [7] Energy saving potential of liquid desiccant in evaporative-cooling-assisted 100% outdoor air system
    Kim, Min-Hwi
    Park, Jun-Seok
    Jeong, Jae-Weon
    ENERGY, 2013, 59 : 726 - 736
  • [8] Energy conservation potential of an indirect and direct evaporative cooling assisted 100% outdoor air system
    Kim, M. H.
    Kim, J. H.
    Kwon, O. H.
    Choi, A. S.
    Jeong, J. W.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2011, 32 (04): : 345 - 360
  • [9] Energy Performance of Liquid Desiccant and Evaporative Cooling-Assisted 100% Outdoor Air Systems under Various Climatic Conditions
    Li, Shiying
    Jeong, Jae-Weon
    ENERGIES, 2018, 11 (06):
  • [10] Annual operating energy savings of liquid desiccant and evaporative-cooling-assisted 100% outdoor air system
    Kim, Min-Hwi
    Park, Joon-Young
    Sung, Min-Ki
    Choi, An-Seop
    Jeong, Jae-Weon
    ENERGY AND BUILDINGS, 2014, 76 : 538 - 550