Sterilization effectiveness of in-duct ultraviolet germicidal irradiation system in liquid desiccant and indirect/direct evaporative cooling-assisted 100% outdoor air system
被引:20
|
作者:
Bang, Jong-Il
论文数: 0引用数: 0
h-index: 0
机构:
Sejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South KoreaSejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South Korea
Bang, Jong-Il
[1
]
Park, Joon-Young
论文数: 0引用数: 0
h-index: 0
机构:
Device Solut, Samsung Elect, Facil Team, 90 Samsung Ro, Pyeongtaek Si 17786, Gyeonggi Do, South KoreaSejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South Korea
Park, Joon-Young
[2
]
Jo, Ye-Lim
论文数: 0引用数: 0
h-index: 0
机构:
Sejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South KoreaSejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South Korea
Jo, Ye-Lim
[1
]
Jeong, Jae-Weon
论文数: 0引用数: 0
h-index: 0
机构:
Hanyang Univ, Dept Architectural Engn, 222 Wangsimni Ro, Seoul 04763, South KoreaSejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South Korea
Jeong, Jae-Weon
[3
]
Choi, Anseop
论文数: 0引用数: 0
h-index: 0
机构:
Sejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South KoreaSejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South Korea
Choi, Anseop
[1
]
论文数: 引用数:
h-index:
机构:
Sung, Minki
[1
]
机构:
[1] Sejong Univ, Dept Architectural Engn, 209 Neungdong Ro, Seoul 05006, South Korea
[2] Device Solut, Samsung Elect, Facil Team, 90 Samsung Ro, Pyeongtaek Si 17786, Gyeonggi Do, South Korea
[3] Hanyang Univ, Dept Architectural Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
Liquid desiccant and indirect/direct evaporative cooling-assisted 100% Outdoor air system (LD-IDECOAS);
In-duct ultraviolet germicidal irradiation (ID-UVGI);
Irradiation analysis;
Microbial contamination;
Indoor air quality;
PERFORMANCE;
CONTAMINATION;
BACTERIA;
DISINFECTION;
D O I:
10.1016/j.buildenv.2020.107350
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
Microorganism contamination in air conditioning systems can cause respiratory diseases in building occupants. This study aims to evaluate and predict the performance of an in-duct ultraviolet germicidal irradiation (IDUVGI) system to reduce the microorganisms that can grow in the liquid desiccant and indirect/direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS). Bacteria and mold on the direct evaporative cooling (DEC) element and in the outdoor and supply air were monitored using a swab and Petrifilm for surfaces and impact sampler for air during the operation of the LD-IDECOAS. Microbial contamination was first verified in the air before performing the sterilization experiment. The experimental results showed that the airborne bacteria were reduced by 78.3% after the operation of the ID-UVGI system but there was almost no reduction in the airborne mold. The bacteria and mold concentration on the DEC surface were decreased by 99.7% and 96.7% respectively 3 h after the ID-UVGI operation. Even after the ID-UVGI system was operated for 6 days, the microbial contamination in the downstream water was not decreased significantly; the inside of the DEC element was suspected to be improperly sterilized. The operating times of the ID-UVGI system needed to inactivate the microorganisms were predicted from the UV-C intensity distribution by irradiation analysis. Legionella sp. and Penicillium sp. were predicted to be inactivated by 99.9% with UV-C exposures of 6 s and 15 min 57 s or less respectively when the LD-IDECOAS is operated at the highest air flow rate.