An Improvement of Voltage Unbalance in a Low Voltage 11/0.4 kV Electric Power distribution Network under 3-phase Unbalance Load Condition using Dynamic Voltage Restorer

被引:0
|
作者
Taiwo, Ogunboyo Patrick [1 ]
Tiako, Remy [1 ]
Davidson, Innocent E. [2 ]
机构
[1] Univ KwaZulu Natal, Elect Elect & Comp Engn Discipline, Durban, South Africa
[2] Durban Univ Technol, Dept Elect Power Engn, Durban, South Africa
关键词
unbalance voltage; power quality; low voltage; distribution network; injection voltage; dynamic voltage restorer; SAG;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The compensation of voltage unbalance disturbance in low voltage electric power distribution system using improved d-q-o and PI controller techniques is the focus of this paper. There are several methods to mitigate voltage unbalance. A very effective method of voltage unbalance compensation is the use of dynamic voltage restorer. Dynamic voltage restorer is a series-connected advanced power electronic custom-based tool. It is employed to mitigate voltage disturbances in low voltage electric power distribution network. Dynamic voltage restorer is installed in the network between the source voltage and the loads to correct voltage disturbances affecting the load voltage. This report presents the modelling of dynamic voltage restorer for voltage unbalance correction in a low voltage 11/0.4 kV electric power distribution network using MATLAB/Simulink Sim Power System tool box. Results obtained from simulation with distribution length 0.5 km to 5 km for 3-phase unbalanced loads are within the permissible nominal voltage tolerance of +/- 5% at the customer's terminal when dynamic voltage restorer is connected to the network. This is not the case when a dynamic voltage restorer is not plugged in. The results obtained demonstrate the effectiveness of this device's performance in improving voltage unbalance in a low voltage electrical power distribution from lengths 0.5 km to 5 km. The balance of the paper discusses some recommendations for an efficient, reliable and cost-effective method for improving voltage profile and reducing the voltage unbalance in 3-phase unbalance load to acceptable standards.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 50 条
  • [41] Power Quality Improvement in Distribution System Based on Dynamic Voltage Restorer Using Rational Energy Transformative Optimization Algorithm
    L. Nagarajan
    M. Senthilkumar
    Journal of Electrical Engineering & Technology, 2022, 17 : 121 - 137
  • [42] Power Quality Improvement in Distribution System Based on Dynamic Voltage Restorer Using Rational Energy Transformative Optimization Algorithm
    Nagarajan, L.
    Senthilkumar, M.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (01) : 121 - 137
  • [43] Power quality improvement in distribution system based on dynamic voltage restorer using PI tuned fuzzy logic controller
    Reddy, S. Gopal
    Ganapathy, S.
    Manikandan, M.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2022, (01) : 44 - 50
  • [44] Power Quality Improvement and Low Voltage Ride Through Capability in Hybrid Wind-PV Farms Grid-Connected Using Dynamic Voltage Restorer
    Benali, Abdelkrim
    Khiat, Mounir
    Allaoui, Tayeb
    Denai, Mouloud
    IEEE ACCESS, 2018, 6 : 68634 - 68648
  • [45] Voltage Unbalance Analysis of Distribution Systems Using a Three-Phase Power Flow ans a Genetic Algorithm for PEV Fleets Scheduling
    Jimenez, Alejandra
    Garcia, Norberto
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [46] Study on closed loop operation of low voltage distribution network under three-phase unbalanced condition
    Zhang, Jing
    Jin, Ming
    Cheng, Yunguo
    Wang, Dejun
    Zhou, Kang
    Yan, Xin
    2017 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION (ESMA2017), VOLS 1-4, 2018, 108
  • [47] Three-phase Power Flow Calculation of Low Voltage Distribution Network Considering Characteristics of Residents Load
    Wang Yaping
    Lin Shunjiang
    Yang Zhibin
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [48] Control of a 3-phase 4-leg active power filter under non-ideal mains voltage condition
    Ucar, M.
    Ozdemir, E.
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (01) : 58 - 73
  • [49] Thermal Analysis of Low-Power Three-Phase Induction Motors Operating under Voltage Unbalance and Inter-Turn Short Circuit Faults
    Adouni, Amel
    J. Marques Cardoso, Antonio
    MACHINES, 2021, 9 (01) : 1 - 11
  • [50] Shunt Active Power Filter for 3-phase 3-wire Nonlinear Load under Unbalanced and Distorted PCC Voltage using Notch Adaptive Filter
    Nguyen Duc Tuyen
    Fujita, Goro
    Bin Muhtazaruddin, Mohd Nabil
    Funabashi, Toshihisa
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,