An Improvement of Voltage Unbalance in a Low Voltage 11/0.4 kV Electric Power distribution Network under 3-phase Unbalance Load Condition using Dynamic Voltage Restorer

被引:0
|
作者
Taiwo, Ogunboyo Patrick [1 ]
Tiako, Remy [1 ]
Davidson, Innocent E. [2 ]
机构
[1] Univ KwaZulu Natal, Elect Elect & Comp Engn Discipline, Durban, South Africa
[2] Durban Univ Technol, Dept Elect Power Engn, Durban, South Africa
关键词
unbalance voltage; power quality; low voltage; distribution network; injection voltage; dynamic voltage restorer; SAG;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The compensation of voltage unbalance disturbance in low voltage electric power distribution system using improved d-q-o and PI controller techniques is the focus of this paper. There are several methods to mitigate voltage unbalance. A very effective method of voltage unbalance compensation is the use of dynamic voltage restorer. Dynamic voltage restorer is a series-connected advanced power electronic custom-based tool. It is employed to mitigate voltage disturbances in low voltage electric power distribution network. Dynamic voltage restorer is installed in the network between the source voltage and the loads to correct voltage disturbances affecting the load voltage. This report presents the modelling of dynamic voltage restorer for voltage unbalance correction in a low voltage 11/0.4 kV electric power distribution network using MATLAB/Simulink Sim Power System tool box. Results obtained from simulation with distribution length 0.5 km to 5 km for 3-phase unbalanced loads are within the permissible nominal voltage tolerance of +/- 5% at the customer's terminal when dynamic voltage restorer is connected to the network. This is not the case when a dynamic voltage restorer is not plugged in. The results obtained demonstrate the effectiveness of this device's performance in improving voltage unbalance in a low voltage electrical power distribution from lengths 0.5 km to 5 km. The balance of the paper discusses some recommendations for an efficient, reliable and cost-effective method for improving voltage profile and reducing the voltage unbalance in 3-phase unbalance load to acceptable standards.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 50 条
  • [31] Assessment of Voltage Unbalance Due to single phase Rooftop Photovoltaic Panels in Residential Low Voltage Distribution Network A Study on a Real LV Network in Western Australia
    Kharrazi, Ali
    Sreeram, Victor
    Mishra, Yateendra
    2017 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2017,
  • [32] Power Quality improvement using Self Supported Dynamic Voltage Restorer (DVR) in Distribution System
    Archana, T. C.
    Reji, P.
    PROCEEDINGS OF 2015 IEEE INTERNATIONAL CONFERENCE ON POWER, INSTRUMENTATION, CONTROL AND COMPUTING (PICC), 2015,
  • [33] Electricity-consumption-data-driven Stochastic Modeling and Unbalance Assessment of Load in Low-Voltage Distribution Network
    Xue S.
    Jia Q.
    Zhang K.
    Gao Z.
    Liang J.
    Li Y.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (08): : 143 - 153
  • [34] The Control Technology of Three-Phase Unbalance Load in Low Voltage Distribution Networks Based on Coordinated Controlled SVGs
    Deng H.
    Li G.
    Zhou X.
    Li H.
    Wang H.
    Wang, Hao (whhao1@163.com), 2017, China Machine Press (32): : 75 - 83
  • [35] Unbalance Mitigation via Phase-Switching Device and Static Var Compensator in Low-Voltage Distribution Network
    Liu, Bin
    Meng, Ke
    Dong, Zhao Yang
    Wong, Peter K. C.
    Ting, Tian
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (06) : 4856 - 4869
  • [36] Power quality improvement using dynamic voltage restorer in distribution system PT. DSS Power Plant
    Martiningsih, Wahyuni
    Prakoso, Untung Yudho
    Herudin
    1ST INTERNATIONAL CONFERENCE ON INDUSTRIAL, ELECTRICAL AND ELECTRONICS (ICIEE 2018), 2018, 218
  • [37] Power Quality Improvement Using an Enhanced Network-Side-Shunt-Connected Dynamic Voltage Restorer
    Fereidouni, Alireza
    Masoum, Mohammad A. S.
    Moghbel, Moayed
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2015, 16 (05) : 451 - 472
  • [38] Dynamic Voltage Stability Assessment of an Electric Power Network using Composite Load Models
    Pereira, R. M. Monteiro
    Pereira, Adelino J. C.
    Ferreira, C. M. Machado
    Barbosa, F. P. Maciel
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 475 - 479
  • [39] Theoretical Line Loss Calculation System of Low-voltage Distribution Network Based On Three-phrase Dynamic Unbalance
    Zhang ShiHong
    Yu JianGMing
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 362 - 366
  • [40] Voltage Quality Improvement in Low Voltage Distribution Networks Using Reactive Power Capability of Single-Phase PV Inverters
    Zeraati, Mehdi
    Golshan, Mohamad Esmail Hamedani
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (05) : 5057 - 5065