Thermoeconomic cost analysis and comparison of methodologies for Dora II binary geothermal power plant

被引:27
|
作者
Yilmaz, Ceyhun [1 ]
机构
[1] Afyon Kocatepe Univ, Dept Mech Engn, TR-03200 Afyon, Turkey
关键词
Geothermal power; Thermoeconomic analysis; SPECO; MOPSA; Moran method; EXERGOECONOMIC ANALYSIS; PERFORMANCE ANALYSIS; SYSTEM; TEMPERATURE; EXERGY; OPTIMIZATION; ENERGY;
D O I
10.1016/j.geothermics.2018.04.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Three thermoeconomic methodologies, specific exergy costing (SPECO), modified productive structure analysis (MOPSA) and the Moran, were used to compare cost flows and products interactions between system components in the context of an existing binary geothermal power plant in western Turkey. With the objective of identifying advantages and disadvantages, exergy and exergoeconomic analyses were conducted using actual plant data to evaluate plant performances and thermoeconomic costs. Overall energy and exergy efficiencies of the plant were calculated as 13.5% and 47.3% and unit exergetic electricity costs were determined as 0.0436 $/kWh for MOPSA, 0.0367 $/kWh for SPECO and 0.0355 $/kWh for Moran.
引用
收藏
页码:48 / 57
页数:10
相关论文
共 50 条
  • [41] Structural theory and thermoeconomic diagnosis Part II: Application to an actual power plant
    Valero, A
    Lerch, F
    Serra, L
    Royo, J
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (9-12) : 1519 - 1535
  • [42] Performance analysis of Germencik Geothermal Power Plant
    Unverdi, Murat
    Cerci, Yunus
    ENERGY, 2013, 52 : 192 - 200
  • [43] ORC fluids selection for a bottoming binary geothermal power plant integrated with a CSP plant
    Boukelia, T. E.
    Arslan, O.
    Djimli, S.
    Kabar, Y.
    ENERGY, 2023, 265
  • [44] Thermoeconomic analysis of a hybrid cogeneration plant with use of near-surface geothermal sources in Turkey
    Tozlu, Alperen
    Gencaslan, Betul
    Ozcan, Hasan
    RENEWABLE ENERGY, 2021, 176 : 237 - 250
  • [45] Performance optimisation of the combined single flash binary geothermal power plant
    Dagdas, Ahmet
    INTERNATIONAL JOURNAL OF EXERGY, 2011, 8 (02) : 194 - 210
  • [46] Thermodynamics study of flash-binary cycle in geothermal power plant
    Pasek, Ari Darmawan
    Soelaiman, T. A. Fauzi
    Gunawan, Christian
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (09): : 5218 - 5223
  • [47] Performance Analysis of Supercritical Binary Geothermal Power Plants
    Dagdas, Ahmet
    Akkoyunlu, Mustafa Tahir
    Basaran, Tugrul
    ADVANCES IN MECHANICAL ENGINEERING, 2015, 7 (01)
  • [48] DEVELOPMENT OF PLANT PERFORMANCE ANALYSIS SYSTEM FOR GEOTHERMAL POWER PLANT
    Nakao, Yoshinobu
    Takahashi, Toru
    Watanabe, Yutaka
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 2, 2012, : 551 - 555
  • [49] Energy, exergy, and thermoeconomic analysis of a natural gas combined power plant
    Al-Dulaimi, Bashar Mohammed
    Bayat, Mutlucan
    Tekir, Mutlu
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024,
  • [50] Thermoeconomic Analysis and Assessment of Gaziantep Municipal Solid Waste Power Plant
    Tozlu, A.
    Abusoglu, A.
    Ozahi, E.
    ACTA PHYSICA POLONICA A, 2017, 132 (03) : 513 - 517