Label-Free Detection of Salivary Pepsin Using Gold Nanoparticle/Polypyrrole Nanocoral Modified Screen-Printed Electrode

被引:14
|
作者
Lee, Doyeon [1 ]
Lee, Young Ju [2 ]
Eun, Young-Gyu [3 ]
Lee, Gi-Ja [1 ,2 ]
机构
[1] Kyung Hee Univ, Grad Sch, Dept Med Engn, Seoul 130701, South Korea
[2] Kyung Hee Univ, Coll Med, Dept Biomed Engn, Seoul 130701, South Korea
[3] Kyung Hee Univ, Med Ctr, Dept Otolaryngol Head & Neck Surg, Seoul 130702, South Korea
关键词
pepsin; saliva; laryngopharyngeal reflux; polypyrrole nanocorals; electrochemical immunosensor; GASTROESOPHAGEAL-REFLUX DISEASE; LARYNGOPHARYNGEAL REFLUX; CONDUCTING POLYMER; IMMUNOSENSOR; POLYPYRROLE; NANOPARTICLES; DIAGNOSIS; MARKER;
D O I
10.3390/s18061685
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection of salivary pepsin has been given attention as a new diagnostic tool for laryngopharyngeal reflux (LPR) disease, because saliva collection is non-invasive and relatively comfortable. In this study, we prepared polypyrrole nanocorals (PPNCs) on a screen-printed carbon electrode (SPCE) by a soft template synthesis method, using -naphthalenesulfonic acid (NSA) (for short, PPNCs/SPCE). Gold nanoparticles (GNPs) were then decorated on PPNCs/SPCE by electrodeposition (for short, GNP/PPNCs/SPCE). To construct the immunosensor, pepsin antibody was immobilized on GNP/PPNCs/SPCE. Next, citric acid was applied to prevent non-specific binding and change the electrode surface charge before pepsin incubation. Electrochemical stepwise characterization was performed using cyclic voltammetry, and immunosensor response toward different pepsin concentrations was measured by differential pulsed voltammetry. As a result, our electrochemical immunosensor showed a sensitive detection performance toward pepsin with a linear range from 6.25 to 100 ng/mL and high specificity toward pepsin, as well as a low limit of detection of 2.2 ng/mL. Finally, we quantified the pepsin levels in saliva samples of LPR patients (n = 2), showing that the results were concordant with those of a conventional ELISA method. Therefore, we expect that this electrochemical immunosensor could be helpful for preliminarily diagnosing LPR through the detection of pepsin in saliva.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [21] An Electrochemical Enzyme Biosensor for Ammonium Detection in Aquaculture Using Screen-Printed Electrode Modified by Gold Nanoparticle/Polymethylene Blue
    Wang, Cong
    Wang, Tan
    Li, Zhen
    Xu, Xianbao
    Zhang, Xiaoshuan
    Li, Daoliang
    BIOSENSORS-BASEL, 2021, 11 (09):
  • [22] New label free CA125 detection based on gold nanostructured screen-printed electrode
    Ravalli, A.
    dos Santos, G. Pilon
    Ferroni, M.
    Faglia, G.
    Yamanaka, H.
    Marrazza, G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 179 : 194 - 200
  • [23] Label-free electrochemical detection for food allergen using screen printed carbon electrode
    Saito, Masato
    Kitsunai, Masaaki
    Ahmed, Minhaz Uddin
    Sugiyama, Shigeru
    Tamiya, Eiichi
    ELECTROCHEMISTRY, 2008, 76 (08) : 606 - 609
  • [24] Highly Sensitive Label-Free Electrochemical Aptasensor Based on Screen-Printed Electrode for Detection of Cadmium (II) Ions
    Li, Yu
    Ran, Guojing
    Lu, Gen
    Ni, Xinyu
    Liu, Daling
    Sun, Jianxia
    Xie, Chunfang
    Yao, Dongsheng
    Bai, Weibin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B449 - B455
  • [25] A modified nanostructured graphene-gold nanoparticle carbon screen-printed electrode for the sensitive voltammetric detection of rutin
    Apetrei, I. M.
    Apetrei, C.
    MEASUREMENT, 2018, 114 : 37 - 43
  • [26] Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode
    Shehata, M.
    Fekry, Amany M.
    Walcarius, Alain
    SENSORS, 2020, 20 (10)
  • [27] Label-free electrochemical impedance immunosensor based on modified screen-printed gold electrodes for the diagnosis of canine visceral leishmaniasis
    Cordeiro, Tais A. R.
    Goncalves, Marcus V. C.
    Franco, Diego L.
    Reis, Alexandre B.
    Martins, Helen R.
    Ferreira, Lucas F.
    TALANTA, 2019, 195 : 327 - 332
  • [28] Label-free impedimetric aptasensor for lysozyme detection based on carbon nanotube-modified screen-printed electrodes
    Rohrbach, Falk
    Karadeniz, Hakan
    Erdem, Arzum
    Famulok, Michael
    Mayer, Guenter
    ANALYTICAL BIOCHEMISTRY, 2012, 421 (02) : 454 - 459
  • [29] Screen-printed Modified Diamond Electrode for Glucose Detection
    Kondo, Takeshi
    Horitani, Masaru
    Sakamoto, Hironori
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Yuasa, Makoto
    CHEMISTRY LETTERS, 2013, 42 (04) : 352 - 354
  • [30] A high sensitive label-free immunosensor for the determination of human serum IgG using overoxidized polypyrrole decorated with gold nanoparticle modified electrode
    Tabrizi, Mahmoud Amouzadeh
    Shamsipur, Mojtaba
    Mostafaie, Ali
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 59 : 965 - 969