Parallel transmission RF pulse design with strict temperature constraints

被引:8
|
作者
Deniz, Cem M. [1 ,2 ,3 ,4 ,5 ]
Carluccio, Giuseppe [1 ,2 ,3 ]
Collins, Christopher [1 ,2 ,3 ,4 ]
机构
[1] NYU, Sch Med, Ctr Adv Imaging Innovat & Res CAI2R, New York, NY USA
[2] NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, New York, NY USA
[3] NYU, Sch Med, Sackler Inst Grad Biomed Sci, New York, NY USA
[4] NYU, Tandon Sch Engn, NYU WIRELESS, Brooklyn, NY USA
[5] RF Test Labs Inc, New York, NY USA
关键词
parallel transmission; RF pulse design; temperature constraints; temperature correlation matrices; WHOLE-BODY SAR; IN-VIVO; ABSORPTION RATE; ANATOMICAL MODELS; LOCAL SAR; MRI; RESOLUTION; TISSUE; POWER; COIL;
D O I
10.1002/nbm.3694
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
RF safety in parallel transmission (pTx) is generally ensured by imposing specific absorption rate (SAR) limits during pTx RF pulse design. There is increasing interest in using temperature to ensure safety in MRI. In this work, we present a local temperature correlation matrix formalism and apply it to impose strict constraints on maximum absolute temperature in pTx RF pulse design for head and hip regions. Electromagnetic field simulations were performed on the head and hip of virtual body models. Temperature correlation matrices were calculated for four different exposure durations ranging between 6 and 24min using simulated fields and body-specific constants. Parallel transmission RF pulses were designed using either SAR or temperature constraints, and compared with each other and unconstrained RF pulse design in terms of excitation fidelity and safety. The use of temperature correlation matrices resulted in better excitation fidelity compared with the use of SAR in parallel transmission RF pulse design (for the 6min exposure period, 8.8% versus 21.0% for the head and 28.0% versus 32.2% for the hip region). As RF exposure duration increases (from 6min to 24min), the benefit of using temperature correlation matrices on RF pulse design diminishes. However, the safety of the subject is always guaranteed (the maximum temperature was equal to 39 degrees C). This trend was observed in both head and hip regions, where the perfusion rates are very different.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] System and SAR characterization in parallel RF transmission
    Zhu, Yudong
    Alon, Leeor
    Deniz, Cem M.
    Brown, Ryan
    Sodickson, Daniel K.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1367 - 1378
  • [22] Adapted RF pulse design for SAR reduction in parallel excitation with experimental verification at 9.4 T
    Wu, Xiaoping
    Akgun, Can
    Vaughan, J. Thomas
    Andersen, Peter
    Strupp, John
    Ugurbil, Kamil
    Van de Moortele, Pierre-Francois
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2010, 205 (01) : 161 - 170
  • [23] Advanced Three-Dimensional Tailored RF Pulse Design in Volume Selective Parallel Excitation
    Shao, Tingting
    Xia, Ling
    Tao, Guisheng
    Chi, Jieru
    Liu, Feng
    Crozier, Stuart
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (05) : 997 - 1007
  • [24] Ultra-high field MRI: parallel-transmit arrays and RF pulse design
    Williams, Sydney N.
    McElhinney, Paul
    Gunamony, Shajan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (02):
  • [25] Design a logamp RF pulse detector
    Nash, E
    [J]. MICROWAVES & RF, 2000, 39 (01) : 62 - +
  • [26] Multiphoton parallel transmission (MP-pTx): Pulse design methods and numerical validation
    Drago, John M.
    Guerin, Bastien
    Stockmann, Jason P.
    Wald, Lawrence L.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1376 - 1391
  • [27] Practical Constraints on Nonlinear Transmission Lines for RF Generation
    Lopes Rangel, Elizete G.
    Rossi, Jose O.
    Barroso, Joaquim J.
    Yamasaki, Fernanda S.
    Schamiloglu, Edl
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2019, 47 (01) : 1000 - 1016
  • [28] Inverse Design of Photonic Devices with Strict Foundry Fabrication Constraints
    Schubert, Martin F.
    Cheung, Alfred K. C.
    Williamson, Ian A. D.
    Spyra, Aleksandra
    Alexander, David H.
    [J]. ACS PHOTONICS, 2022, 9 (07): : 2327 - 2336
  • [29] The strict time lower bound and optimal schedules for parallel prefix with resource constraints
    Wang, HG
    Nicolau, A
    Siu, KYS
    [J]. IEEE TRANSACTIONS ON COMPUTERS, 1996, 45 (11) : 1257 - 1271
  • [30] The gVERSE RF Pulse: An Optimal Approach to MRI Pulse Design
    Anand, Christopher K.
    Stoyan, Stephen J.
    Terlaky, Tamas
    [J]. MODELING, SIMULATION AND OPTIMIZATION OF COMPLEX PROCESSES, 2008, : 25 - +