Acetabular component orientation in total hip arthroplasty: the impact of obesity

被引:15
|
作者
McArthur, Benjamin A. [1 ]
Vulcano, Ettore [2 ]
Cross, Michael [3 ]
Nguyen, Joseph [3 ]
Della Valle, Alejandro G. [3 ]
Salvati, Eduardo [3 ]
机构
[1] Mayo Clin, Rochester, MN 55905 USA
[2] Univ Insubria, Varese, Italy
[3] Hosp Special Surg, New York, NY 10021 USA
关键词
Obesity; Cup malorientation; Total hip arthroplasty; THA; THR; KNEE REPLACEMENT; IMPINGEMENT; DISLOCATION; ACCURACY; WEAR; AGE; RISK;
D O I
10.5301/hipint.5000125
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Acetabular component position can be an important determinant of joint stability and bearing surface wear after THA. Nonetheless, the incidence of malpositioning is high. Patient obesity, low surgeon volume, and minimally invasive approaches are known risk factors for malposition. As the incidence of obesity continues to increase, it is important to recognise its effect on intraoperative component positioning in THA. Objectives: Our goal was to assess the impact of obesity on component position for a high-volume surgeon using a standard postero-lateral approach. Methods: A consecutive series of 120 obese (BMI >30, mean BMI 34.4) and 120 non-obese patients (mean BMI 25.4), who had undergone primary THA by a single surgeon, were included in our retrospective study. AP pelvis and cross-table radiographs obtained at the first postoperative visit were analysed using EBRA software to determine inclination and anteversion angles. Optimal position was defined as 30-45 degrees of inclination and 5-25 degrees of anteversion. Results: Mean inclination and anteversion were 40.6 (+/-5.4 degrees) and 16.6 (+/-5.5 degrees) respectively, in the obese group and 39 degrees (+/-5.0 degrees) and 16.2 degrees (+/-7.5 degrees) in the non-obese group. In the obese group 89 (74%) patients were within the desired range for both measurements, 31 (26%) were out of range in at least one, compared to 91 (76%) and 29 (24%) in the non-obese group, respectively. The overall incidence of malpositioning was 25% for both groups. Among outliers, mean deviation from the optimal range was = 3.8 degrees in both groups. Conclusions: The risk of component malpositioning in THA may be reduced when surgery is performed by an experienced, high volume surgeon utilising a standard posterolateral approach. In this setting the deleterious effect of obesity may be overcome.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 50 条
  • [31] Fixation principles in total hip arthroplasty: Part 2 Acetabular component
    Breusch, SJ
    Aldinger, PR
    Thomsen, M
    Lukoschek, M
    Ewerbeck, V
    [J]. UNFALLCHIRURG, 2000, 103 (12): : 1017 - 1031
  • [32] Pelvic osteolysis associated with an uncemented acetabular component in total hip arthroplasty
    Kavanagh, BF
    Callaghan, JJ
    Leggon, R
    Heekin, RD
    Wold, L
    [J]. ORTHOPEDICS, 1996, 19 (02) : 159 - 163
  • [33] CEMENTLESS FIXATION OF POLYETHYLENE ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY
    MORSCHER, EW
    DICK, W
    KERNEN, V
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1982, 99 (04) : 223 - 230
  • [34] Computer navigation of the acetabular component in total hip arthroplasty: a narrative review
    Davenport, Dominic
    Kavarthapu, Venu
    [J]. EFORT OPEN REVIEWS, 2016, 1 (07): : 279 - 285
  • [35] Body mass index and acetabular component position in total hip arthroplasty
    McBride, Andrew
    Flynn, Jennifer
    Miller, George
    Barnes, Matthew
    Mackie, Scott
    [J]. ANZ JOURNAL OF SURGERY, 2013, 83 (03) : 171 - 174
  • [36] Catastrophic Wear of an Acetabular Component Misdiagnosed as Total Hip Arthroplasty Dislocation
    Papaioannou, Ioannis
    Pantazidou, Georgia
    Chatziperi, Stamatia
    Baikousis, Andreas
    Korovessis, Panagiotis
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (11)
  • [37] A NEW TECHNIQUE FOR REMOVAL OF THE TOTAL HIP-ARTHROPLASTY ACETABULAR COMPONENT
    ANSPACH, WE
    LACHIEWICZ, PF
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (268) : 152 - 156
  • [38] INCIDENCE AND MECHANISM OF FAILURE OF CEMENTED ACETABULAR COMPONENT IN TOTAL HIP ARTHROPLASTY
    EFTEKHAR, NS
    NERCESSIAN, O
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1988, 19 (03) : 557 - 566
  • [39] Does Fluoroscopy Improve Acetabular Component Placement in Total Hip Arthroplasty?
    Beamer, Brandon S.
    Morgan, Jordan H.
    Barr, Christopher
    Weaver, Michael J.
    Vrahas, Mark S.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (12) : 3953 - 3962
  • [40] Effect of acetabular component anteversion on dislocation mechanisms in total hip arthroplasty
    Higa, Masaru
    Tanino, Hiromasa
    Abo, Masayoshi
    Kakunai, Satoshi
    Banks, Scott A.
    [J]. JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1810 - 1813