Acetabular component orientation in total hip arthroplasty: the impact of obesity

被引:15
|
作者
McArthur, Benjamin A. [1 ]
Vulcano, Ettore [2 ]
Cross, Michael [3 ]
Nguyen, Joseph [3 ]
Della Valle, Alejandro G. [3 ]
Salvati, Eduardo [3 ]
机构
[1] Mayo Clin, Rochester, MN 55905 USA
[2] Univ Insubria, Varese, Italy
[3] Hosp Special Surg, New York, NY 10021 USA
关键词
Obesity; Cup malorientation; Total hip arthroplasty; THA; THR; KNEE REPLACEMENT; IMPINGEMENT; DISLOCATION; ACCURACY; WEAR; AGE; RISK;
D O I
10.5301/hipint.5000125
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Acetabular component position can be an important determinant of joint stability and bearing surface wear after THA. Nonetheless, the incidence of malpositioning is high. Patient obesity, low surgeon volume, and minimally invasive approaches are known risk factors for malposition. As the incidence of obesity continues to increase, it is important to recognise its effect on intraoperative component positioning in THA. Objectives: Our goal was to assess the impact of obesity on component position for a high-volume surgeon using a standard postero-lateral approach. Methods: A consecutive series of 120 obese (BMI >30, mean BMI 34.4) and 120 non-obese patients (mean BMI 25.4), who had undergone primary THA by a single surgeon, were included in our retrospective study. AP pelvis and cross-table radiographs obtained at the first postoperative visit were analysed using EBRA software to determine inclination and anteversion angles. Optimal position was defined as 30-45 degrees of inclination and 5-25 degrees of anteversion. Results: Mean inclination and anteversion were 40.6 (+/-5.4 degrees) and 16.6 (+/-5.5 degrees) respectively, in the obese group and 39 degrees (+/-5.0 degrees) and 16.2 degrees (+/-7.5 degrees) in the non-obese group. In the obese group 89 (74%) patients were within the desired range for both measurements, 31 (26%) were out of range in at least one, compared to 91 (76%) and 29 (24%) in the non-obese group, respectively. The overall incidence of malpositioning was 25% for both groups. Among outliers, mean deviation from the optimal range was = 3.8 degrees in both groups. Conclusions: The risk of component malpositioning in THA may be reduced when surgery is performed by an experienced, high volume surgeon utilising a standard posterolateral approach. In this setting the deleterious effect of obesity may be overcome.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 50 条
  • [21] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Ozan, Firat
    Kahraman, Murat
    Baktir, Ali
    Gencer, Kursat
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [22] Spinopelvic mobility and acetabular component position for total hip arthroplasty
    Stefl, M.
    Lundergan, W.
    Heckmann, N.
    McKnight, B.
    Ike, H.
    Murgai, R.
    Dorr, L. D.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (01): : 37 - 45
  • [23] Total hip arthroplasty with the use of nonmodular cementless acetabular component
    Kim, SY
    Kim, DH
    Oh, CW
    Kim, PT
    Ihn, JC
    Kim, SY
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 632 - 638
  • [24] The influence of acetabular component position on wear in total hip arthroplasty
    Wan, Zhinian
    Boutary, Myriam
    Dorr, Lawrence D.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 51 - 56
  • [25] What is the Fate of Total Hip Arthroplasty (THA) Acetabular Component Orientation When Evaluated in the Standing Position?
    Tiberi, John V., III
    Antoci, Valentin
    Malchau, Henrik
    Rubash, Harry E.
    Freiberg, Andrew A.
    Kwon, Young-Min
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (09): : 1555 - 1560
  • [26] Total Hip Arthroplasty Functional Outcomes Are Independent of Acetabular Component Orientation When a Polyethylene Liner Is Used
    Bobman, Jacob T.
    Danoff, Jonathan R.
    Babatunde, Oladapo M.
    Zhu, Kaicen
    Peyser, Katie
    Geller, Jeffrey A.
    Gorroochurn, Prakash
    Macaulay, William
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 830 - U209
  • [27] Functional orientation of the acetabular component in ceramic-on-ceramic total hip arthroplasty and its relevance to squeaking
    Pierrepont, J. W.
    Feyen, H.
    Miles, B. P.
    Young, D. A.
    Bare, J. V.
    Shimmin, A. J.
    [J]. BONE & JOINT JOURNAL, 2016, 98B (07): : 910 - 916
  • [28] Effects of acetabular component orientation on dislocation propensity for small-head-size total hip arthroplasty
    Nadzadi, ME
    Pedersen, DR
    Callaghan, JJ
    Brown, TD
    [J]. CLINICAL BIOMECHANICS, 2002, 17 (01) : 32 - 40
  • [29] The outcome of the uncemented acetabular component in delayed total hip arthroplasty following acetabular fractures
    El-Bakoury, A.
    Khedr, W.
    Williams, M.
    Eid, Y.
    Hammad, A. S.
    [J]. BONE & JOINT OPEN, 2021, 2 (12): : 1067 - 1074
  • [30] Effect of acetabular cup position and orientation in cemented total hip arthroplasty
    Hirakawa, K
    Mitsugi, N
    Koshino, T
    Saito, T
    Hirasawa, Y
    Kubo, T
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 135 - 142