The vibration performance experiment of Tuned Liquid Damper and Tuned Liquid Column damper

被引:15
|
作者
Kim, Young-Moon [1 ]
You, Ki-Pyo
Cho, Ji-Eun
Hong, Dong-Pyo
机构
[1] Chonbuk Natl Univ, Dept Architecture & Urban Engn, Chonju 561756, South Korea
[2] Chonbuk Natl Univ, Dept Precis Mech Engn, Chonju 561756, South Korea
关键词
Tuned Liquid Damper; Tuned Liquid Column; shaking table; wave; base shear force; energy dissipation;
D O I
10.1007/BF02915943
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Tuned Liquid damper and Tuned Liquid Column are kind of passive mechanical damper which relies on the sloshing of liquid in a rigid tank for suppressing structural vibrations. TLD and TLCD are attributable to several potential advantages - low costs; easy to install in existing structures; effective even for small-amplitude vibrations. In this paper, the shaking table experiments were conducted to investigate the characteristics of water sloshing motion in TLD (rectangular, circular) and TLCD. The parameter obtained from the experiments were wave height, base shear force and energy dissipation. The shaking table experiments show that the liquid sloshing relies on amplitude of shaking table and frequency of tank. The TLCD was more effective control vibration than TLD.
引用
收藏
页码:795 / 805
页数:11
相关论文
共 50 条
  • [21] PID Control of structure with Tuned Liquid Column Damper
    Abubaker, Salsala
    Nagan, S.
    Nasar, T.
    [J]. PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND CONTROL (ISCO'16), 2016,
  • [22] Investigation of an improved tuned liquid column gas damper for the vertical vibration control
    Liu, Kaifang
    Shi, Qingxuan
    Liu, Yanhui
    Liu, Lulu
    Zhou, Fulin
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2023, 196
  • [23] Numerical research on nonlinear liquid sloshing and vibration control performance of tuned liquid damper
    He, Xin
    Li, Chao
    Chen, Lingwei
    Yang, Junhui
    Hu, Gang
    Ou, Jinping
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [24] Earthquake mitigation in building construction by tuned liquid column damper
    Ziegler, F.
    [J]. ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2005, 122 (05): : 164 - 168
  • [25] Active Tuned Liquid Column Gas Damper in Structural Control
    Hochrainer, Markus J.
    [J]. DYNAMICS OF CIVIL STRUCTURES, VOL 2, 2015, : 467 - 473
  • [26] Tuning Performances of Tuned Double Liquid Column/Mass Damper
    Dai, Naxin
    Huang, Dongyang
    Hu, Shengrong
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 4, 2009, : 375 - 379
  • [27] PResearch on Tuning Performances of Tuned Liquid Column/Mass Damper
    Huang, Dongyang
    Tan, Ping
    Jiang, Guoping
    [J]. PROCEEDINGS OF FIRST INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION, VOL V: MODELLING AND SIMULATION IN MECHANICS AND MANUFACTURE, 2008, : 384 - 388
  • [28] Tuned liquid column damper for suppressing pitching motion of structures
    Xue, SD
    Ko, JM
    Xu, YL
    [J]. ENGINEERING STRUCTURES, 2000, 22 (11) : 1538 - 1551
  • [29] Investigations on the Performance of a Novel Semi-active Tuned Liquid Column Damper
    Altay, Okyay
    Nolteernsting, Felix
    Stemmler, Sebastian
    Abel, Dirk
    Klinkel, Sven
    [J]. X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 1580 - 1585
  • [30] Experimental and numerical investigation of a large tuned liquid column damper
    Cammelli, Stefano
    Li, Yin Fai
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2016, 169 (08) : 635 - 642