Effects of bifurcation-specific and conventional stents on coronary bifurcation flow. An experimental and numerical study

被引:12
|
作者
Garcia Garcia, J. [1 ]
Garcia Carrascal, P. [2 ]
Castro Ruiz, F. [2 ]
Manuel Martin, F. [1 ]
Fernandez, J. A. [3 ]
机构
[1] Univ Politecn Madrid, Escuela Tecn Super Ingenieros Ind, Dept Ingn Energet, C Jose Gutierrez Abascal 2, E-28006 Madrid, Spain
[2] Univ Valladolid, Escuela Ingn Ind, Dept Ingn Energet & Fluidomecan, Paseo Cauce 59, E-47011 Valladolid, Spain
[3] Hosp Univ Puerta Hierro, Majadahonda, Spain
关键词
Computational fluid dynamics; Coronary bifurcation; Stenting techniques; Image-based reconstruction; Particle image velocimetry; WALL SHEAR-STRESS; MICRO-COMPUTED TOMOGRAPHY; IN-VITRO; FLUID-DYNAMICS; HEMODYNAMICS; IMPLANTATION; ANGIOPLASTY; APPOSITION;
D O I
10.1016/j.jbiomech.2017.01.043
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Our paper builds on existing research into conventional bare metal stents in order to assess new devices specifically designed for coronary bifurcation angioplasty. The first aim is to validate the numerical model against data from in vitro experiments on stented coronary phantoms. A surface mesh was built in accordance with micro-computed tomography images obtained from coronary stents implanted in silicone models and used for numerical analysis. Computational simulations for steady and unsteady cases generally agreed with their experimental counterparts. A second objective is to compare the hemodynamic performance of one of these new devices (Stentys) to that of conventional devices and stenting techniques in a simplified coronary bifurcation model. Four different coronary bifurcation stenting techniques were analyzed. We have focused on factors contributing to restenosis, such as wall shear stress (WSS), oscillatory shear index (OSI), pressure loss, and local normalized helicity (LNH). It was found that bifurcation-specific stents implanted in the side branch led to increased malapposition. This effect has proved to be more important than stent specific design characteristics such as strut size (different for conventional and Stentys stent). This conclusion is confirmed by means of drop in pressure and mechanical energy loss rate calculation; for the latter, the increase ranged from 9% to 17%, depending on the stenting technique, when dedicated stents were implanted in the side branch. The behavior patterns presented in this study should be double-checked against those obtained in more realistic geometries. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:64 / 72
页数:9
相关论文
共 50 条
  • [31] Effect of stenosis eccentricity on the functionality of coronary bifurcation lesions-a numerical study
    Pagiatakis, Catherine
    Tardif, Jean-Claude
    L'Allier, Philippe L.
    Mongrain, Rosaire
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (12) : 2079 - 2095
  • [32] Culotte stenting for coronary bifurcation lesions with 2nd and 3rd generation everolimus-eluting stents: the CELTIC Bifurcation Study
    Walsh, Simon J.
    Hanratty, Colm G.
    Watkins, Stuart
    Oldroyd, Keith G.
    Mulvihill, Niall T.
    Hensey, Mark
    Chase, Alex
    Smith, Dave
    Cruden, Nick
    Spratt, James C.
    Mylotte, Darren
    Johnson, Tom
    Hill, Jonathan
    Hussein, Hafiz M.
    Bogaerts, Kris
    Morice, Marie-Claude
    Foley, David P.
    EUROINTERVENTION, 2018, 14 (03) : 318 - 324
  • [33] Dedicated two-stent technique in complex bifurcation percutaneous coronary intervention with use of everolimus-eluting stents: The EES-bifurcation study
    Kherada, Nisharahmed I.
    Sartori, Samantha
    Tomey, Matthew I.
    Mennuni, Marco G.
    Meelu, Omar A.
    Roy, Swathi
    Mohanty, Bibhu D.
    Baber, Usman
    Pyo, Robert
    Kovacic, Jason C.
    Sweeny, Joseph
    Moreno, Pedro
    Krishnan, Prakash
    Dangas, George D.
    Mehran, Roxana
    Sharma, Samin K.
    Kini, Annapoorna S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (01) : 13 - 17
  • [34] Clinical Outcome in Diabetic Patients Treated for Coronary Bifurcation Lesions by Drug Eluting Stents - Pooled Analysis of the BBC ONE study and the Nordic Bifurcation Studies
    Maeng, Michael
    Hildick-Smith, David
    Holm, Niels R.
    de Belder, Adam
    Niemela, Matti
    Curzen, Nicholaus P.
    Kervinen, Kari
    Erglis, Andrejs
    Kumsars, Indulis
    Oldroyd, Keith G.
    Gunnes, Paal
    Stables, Rodney H.
    Steigen, Terje
    Behan, Miles
    Lassen, Jens F.
    Thuesen, Leif
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B116 - B117
  • [35] Study comparing the double kissing (DK) crush with classical crush for the treatment of coronary bifurcation lesions: the DKCRUSH-1 bifurcation study with drug-eluting stents
    Chen, S. L.
    Zhang, J. J.
    Ye, F.
    Chen, Y. D.
    Patel, T.
    Kawajiri, K.
    Lee, M.
    Kwan, T. W.
    Mintz, G.
    Tan, H. C.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2008, 38 (06) : 361 - 371
  • [36] Numerical study on the influence of a symmetrical stenosis at the carotid sinus on the flow in the carotid bifurcation
    Biomechanical Engineering Laboratory, Sichuan University, Chengdu 610065, China
    不详
    Lixue Xuebao, 2006, 2 (270-275):
  • [37] Numerical study on oscillatory flow in multi-bifurcation of avian lung model
    Sakai E.
    Watanabe T.
    Himeno T.
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2010, 76 (768): : 1206 - 1213
  • [38] NUMERICAL STUDY OF VISCOPLASTIC FLOW IN A T-BIFURCATION: IDENTIFICATION OF STAGNANT REGIONS
    Inacio, Gleison R.
    Tomio, Julio C.
    Vaz, Miguel, Jr.
    Zdanski, Paulo S. B.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2019, 36 (03) : 1279 - 1287
  • [39] The effect of implantation of aortic stents on compliance and blood flow. An experimental study in pigs.
    Pihkala, J
    Thyagarajan, GK
    Taylor, GP
    Nykanen, D
    Benson, LN
    CARDIOLOGY IN THE YOUNG, 2001, 11 (02) : 173 - 181
  • [40] Experimental validation and clinical feasibility of 3D reconstruction of coronary artery bifurcation stents using intravascular ultrasound
    Wu, Wei
    Banga, Akshat
    Oguz, Usama M.
    Zhao, Shijia
    Thota, Anjani Kumar
    Gadamidi, Vinay Kumar
    Dasari, Vineeth S.
    Samant, Saurabhi
    Watanabe, Yusuke
    Murasato, Yoshinobu
    Chatzizisis, Yiannis S.
    PLOS ONE, 2024, 19 (04):