In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation

被引:61
|
作者
Chia, Vanessa A. [1 ]
Esguerra, Roxanna J. [2 ]
Teoh, Khim Hean [1 ]
Teo, Juin Wei [3 ]
Wong, Keng Mun [2 ]
Tan, Keson B. [2 ]
机构
[1] Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, Singapore
[2] Natl Univ Singapore, Fac Dent, 11 Lower Kent Ridge Rd, Singapore 119083, Singapore
[3] Khoo Teck Puat Hosp, Dept Dent, Singapore, Singapore
关键词
accuracy; coordinate measuring machine; digital; implant impression; scan body; three-dimensional; DEFINITIVE CASTS; CONNECTION; PROSTHESES; SYSTEMS; FIT; COMPONENTS; PRECISION; PARALLEL; DEPTH;
D O I
10.11607/jomi.5087
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the three-dimensional (3D) accuracy of conventional impressions (CIs) with digital scans (DSs) using an intraoral scanner (IOS) with intraoral scan bodies (SBs) and varying buccolingual interimplant angulations. A secondary aim was to measure the SB machining tolerance and height with and without application of torque. Materials and Methods: Three master models (MMs) with two implants simulating an implant-supported three-unit fixed partial denture for bone-level implants were used. The implants had buccolingual interimplant angulations of 0, 10, and 20 degrees. Test models for the CI test groups were made with impression copings and polyether impressions. SBs were attached to the MMs, tightened to 15-Ncm torque, and scanned by an IOS for the DS test groups (six test groups, n = 5). A coordinate measuring machine measured linear distortions (dx, dy, dz), 3D distortions (dR), angular distortions (d.x, d.y), and absolute angular distortions (Absd.x, Absd.y) of the physical CI test models and STL files of the DS virtual models relative to the MMs. Metrology software allowed both physical and virtual measurement of geometric targets that were comparable and allowed computation of relative displacements of implant centroids and axes. Results: Mean dR ranged from 31 +/- 14.2 to 45 +/- 3.4 mu m for DS and 18 +/- 8.4 to 36 +/- 6.5 mu m for the CI test groups. Mean Absd.x ranged from 0.041 +/- 0.0318 to 0.794 +/- 0.2739 degrees for DS and 0.073 +/- 0.0618 to 0.545 +/- 0.0615 degrees for the CI test groups. Mean Absd.y ranged from 0.075 +/- 0.0615 to 0.111 +/- 0.0639 degrees for DS and 0.106 +/- 0.0773 to 0.195 +/- 0.1317 degrees for the CI test groups. Two-way analysis of variance showed that the impression technique (P = .012) and implant angulations (P = .007) had a significant effect on dR. Distortions were mostly in the negative direction for DS test groups. Perfect coaxiality of the SB with the implant was never achieved. For SB to implant machining tolerances, the mean absolute horizontal displacement ranged from 4 +/- 1.2 to 7 +/- 2.3 mu m. The SB dz was -5 +/- 3.2 mu m, which increased in the negative direction to -11 +/- 4.9 mu m with torque application (P = .002). Conclusion: Distortions were found for both DS and CI test groups. The best accuracy was obtained with CIs for parallel implants. With angulated implants, conventional and DSs were not significantly different. Excessive torque application that causes negative dz for SB fit would position the virtual implant at a deeper location compared with reality, resulting in possible framework misfit.
引用
收藏
页码:313 / 321
页数:9
相关论文
共 50 条
  • [21] Effect of using scan body accessories and inter-implant distances on the accuracy of complete arch implant digital impressions: An in vitro study
    Ashry, Amal
    Abdelhamid, Ahmed M.
    Ezzelarab, Salah
    Khamis, Mohamed Moataz
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [22] Accuracy of Casts Fabricated by Digital and Conventional Implant Impressions
    Bohner, Lauren
    Hanisch, Marcel
    Canto, Graziela De Luca
    Mukai, Eduardo
    Sesma, Newton
    Tortamano Neto, Pedro
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (02) : 94 - 99
  • [23] Accuracy of printed casts generated from digital implant impressions versus stone casts from conventional implant impressions: A comparative in vitro study
    Alshawaf, Bahaa
    Weber, Hans-Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (08) : 835 - 842
  • [24] Effect of implant angulation and impression technique on impressions of Nobel Active implants
    Hazboun, Gillian Brewer Alexander
    Masri, Radi
    Romberg, Elaine
    Kemp, Joanna
    Driscoll, Carl F.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05): : 425 - 431
  • [25] Influence of Implant Angulation and Implant Number on the Accuracy of Definitive Casts
    Narayane, Abhay Kiran
    Shamsuddeen, Suhana
    Kharat, Swati
    Rashidi, Tabish
    Pandav, Aachut
    Thakur, Manoj Kumar
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 367 - 369
  • [26] Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches
    Rutkunas, Vygandas
    Cius, Darius Jegelevi
    Pletkus, Justinas
    Skalnis, Liudas Au
    Akulauskas, Mykolas
    Eyueboglu, Tan Firat
    Ozcan, Mutlu
    Gedrimiene, Agne
    JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (05): : 302 - 310
  • [27] AN IN VITRO COMPARISON OF THE ACCURACY OF IMPLANT IMPRESSIONS WITH CODED HEALING ABUTMENTS AND DIFFERENT IMPLANT ANGULATIONS
    Al-Abdullah, Khaled
    Zandparsa, Roya
    Finkelman, Matthew
    Hirayama, Hiroshi
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (02): : 90 - 100
  • [28] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113
  • [29] Comparison of the Clinical Accuracy of Digital and Conventional Dental Implant Impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Adaskevicius, Rimas
    Husain, Nadin Al-Haj
    Ozcan, Mutlu
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2020, 28 (04): : 173 - 181
  • [30] Accuracy of digital implant impressions in clinical studies: A systematic review
    Schmidt, Alexander
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (06) : 573 - 585