Validation of a Second-Generation Near-Infrared Spectroscopy Monitor in Children With Congenital Heart Disease

被引:17
|
作者
Nasr, Viviane G. [1 ,2 ]
Bergersen, Lisa T. [3 ,4 ]
Lin, Hung-Mo [5 ]
Benni, Paul B. [6 ]
Bernier, Rachel S. [1 ]
Anderson, Michelle E. [1 ]
Kussman, Barry D. [1 ,2 ]
机构
[1] Boston Childrens Hosp, Dept Anesthesiol Perioperat & Pain Med, 300 Longwood Ave, Boston, MA 02115 USA
[2] Harvard Med Sch, Dept Anaesthesia, Boston, MA 02115 USA
[3] Boston Childrens Hosp, Dept Cardiol, Boston, MA USA
[4] Harvard Med Sch, Dept Pediat, Boston, MA 02115 USA
[5] Icahn Sch Med, Dept Hlth Populat Sci & Policy, Mt Sinai, NY USA
[6] CASMED, Branford, CT USA
来源
ANESTHESIA AND ANALGESIA | 2019年 / 128卷 / 04期
关键词
CEREBRAL OXYGEN-SATURATION; CONCORDANCE CORRELATION-COEFFICIENT; NEURODEVELOPMENTAL OUTCOMES; VENOUS CONTRIBUTIONS; TISSUE OXYGENATION; HEALTHY-VOLUNTEERS; CARDIAC-SURGERY; ECMO PATIENTS; OXIMETER; ARTERIAL;
D O I
10.1213/ANE.0000000000002796
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Cerebral oximetry using near-infrared spectroscopy is a noninvasive optical technology to detect cerebral hypoxia-ischemia and develop interventions to prevent and ameliorate hypoxic brain injury. Cerebral oximeters are calibrated and validated by comparison of the near-infrared spectroscopy-measured cerebral O-2 saturation (SctO(2)) to a "field" or reference O-2 saturation (REF CX) calculated as a weighted average from arterial and jugular bulb oxygen saturations. In this study, we calibrated and validated the second-generation, 5 wavelength, FORE-SIGHT Elite with the medium sensor (source-detector separation 12 and 40 mm) for measurement of SctO(2) in children with congenital heart disease. METHODS: After institutional review board approval and written informed consent, 63 children older than 1 month and >= 2.5 kg scheduled for cardiac catheterization were enrolled. Self-adhesive FORE-SIGHT Elite medium sensors were placed on the right and left sides of the forehead. Blood samples for calculation of REF CX were drawn simultaneously from the aorta or femoral artery and the jugular bulb before (T1) and shortly after (T2) baseline hemodynamic measurements. FORE-SIGHT Elite SctO(2) measurements were compared to the REF CX (REF CX = [0.3 SaO(2)] + [0.7 SjbO(2)]) using Deming regression, least squares linear regression, and Bland-Altman analysis. RESULTS: Sixty-one subjects (4.5 [standard deviation 4.4] years of age; 17 [standard deviation 13] kg, male 56%) completed the study protocol. Arterial oxygen saturation ranged from 64.7% to 99.1% (median 96.0%), jugular bulb venous oxygen saturation from 34.1% to 88.1% (median 68.2%), the REF CX from 43.8% to 91.4% (median 76.9%), and the SctO(2) from 47.8% to 90.8% (median 76.3%). There was a high degree of correlation in SctO(2) between the right and left sensors at a given time point (within subject between sensor correlation r = 0.91 and 95% confidence interval [CI], 0.85-0.94) or between T1 and T2 for the right and left sensors (replicates, within subject between time point correlation r = 0.95 and 95% CI, 0.92-0.96). By Deming regression, the estimated slope was 0.966 (95% CI, 0.786-1.147; P = .706 for testing against null hypothesis of slope = 1) with a y intercept of 2.776 (95% CI, -11.102 to 16.654; P = .689). The concordance correlation coefficient was 0.873 (95% CI, 0.798-0.922). Bland-Altman analysis for agreement between SctO(2) and REF CX that accounted for repeated measures (both in times and sensors) found a bias of -0.30% (95% limits of agreement: -10.56% to 9.95%). CONCLUSIONS: This study calibrated and validated the FORE-SIGHT Elite tissue oximeter to accurately measure SctO(2) in pediatric patients with the medium sensor.
引用
收藏
页码:661 / 668
页数:8
相关论文
共 50 条
  • [31] Combining near-infrared spectroscopy and electroencephalography to monitor brain function
    Salvatori, Giorgia
    Bulf, Luca
    Fonda, Sergio
    Rovati, Luigi
    [J]. 2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 32 - +
  • [32] Near-Infrared spectroscopy to monitor peripheral blood flow perfusion
    Harel F.
    Denault A.
    Ngo Q.
    Dupuis J.
    Khairy P.
    [J]. Journal of Clinical Monitoring and Computing, 2008, 22 (1) : 37 - 43
  • [33] Near-Infrared Spectroscopy to Monitor Nutritional Status of Neonates: A Review
    Miller, Alexander P.
    Mustafa, Fatin Hamimi
    Jones, Peter W.
    Jeffery, Heather E.
    Carberry, Angela E.
    McEwan, Alistair L.
    [J]. IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2020, 13 : 280 - 291
  • [34] Functional near-infrared spectroscopy studies in children
    Shinichiro Nagamitsu
    Yushiro Yamashita
    Hidetaka Tanaka
    Toyojiro Matsuishi
    [J]. BioPsychoSocial Medicine, 6 (1)
  • [35] Functional near-infrared spectroscopy studies in children
    Nagamitsu, Shinichiro
    Yamashita, Yushiro
    Tanaka, Hidetaka
    Matsuishi, Toyojiro
    [J]. BIOPSYCHOSOCIAL MEDICINE, 2012, 6
  • [36] SECOND GENERATION NEAR-INFRARED SPECTROSCOPY MONITOR INSENSITIVELY DETECTS LOW MIXED VENOUS OXYHEMOGLOBIN SATURATIONS FOLLOWING STAGE 1 PALLIATION
    Gagnon, Marie-Helene
    Kussman, Barry
    Kheir, John
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 580 - 580
  • [37] In vivo validation of cerebral near-infrared spectroscopy: a review
    la Cour, Amalie
    Greisen, Gorm
    Hyttel-Sorensen, Simon
    [J]. NEUROPHOTONICS, 2018, 5 (04)
  • [38] Near-Infrared Spectroscopy Usefulness in Validation of Hyperventilation Test
    Sandru, Stefan
    Buzescu, Dan
    Zahiu, Carmen Denise Mihaela
    Spataru, Ana
    Panaitescu, Anca Maria
    Isac, Sebastian
    Balan, Cosmin Ion
    Zagrean, Ana-Maria
    Pavel, Bogdan
    [J]. MEDICINA-LITHUANIA, 2022, 58 (10):
  • [39] Perioperative Cerebral Near-Infrared Spectroscopy Variability and Neurodevelopmental Outcomes in Congenital Heart Patients Reply
    Spaeder, Michael C.
    Klugman, Darren
    Taeb, Mahsheed
    Donofrio, Mary T.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2017, 18 (05) : 500 - 500
  • [40] Intravascular Near-Infrared Spectroscopy Predicts Heart Attacks
    Giglio, Nicholas C.
    Farrow, Samantha
    Sreeram, Kavya
    Grainge, Stephanie
    [J]. Biophotonics International, 2023, 30 (03): : 38 - 42