Monte Carlo X-Ray Tube Simulation for CBCT: Primary Source Phase Space Compression

被引:0
|
作者
Bootsma, G. [1 ]
Nordstrom, H. [2 ]
Eriksson, M. [2 ]
Jaffray, D. [1 ]
机构
[1] Univ Hlth Network, Toronto, ON, Canada
[2] Elekta Instruments AB, Stockholm, Sweden
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I330-Ge
引用
收藏
页码:E153 / E153
页数:1
相关论文
共 50 条
  • [31] Monte Carlo simulation of image properties of an X-ray intensifying screen
    Wang, Y
    Wang, JJ
    Wang, KL
    Liu, GZ
    Liu, YQ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03): : 567 - 570
  • [32] Monte Carlo simulation analysis of X-ray density logging shields
    Liu, Rui
    Yu, Huawei
    Zhu, Qian
    Yue, Aizhong
    Wang, Hu
    Liu, Chaozhuo
    Zhang, Qianwen
    Yang, Shu
    Zhu, Linke
    Zhang, Xiaolei
    He Jishu/Nuclear Techniques, 2024, 47 (08):
  • [33] Monte Carlo Simulation of X-ray Photoemission Electron Microscopic Image
    Zhang, Z. M.
    Tang, T.
    Mao, S. F.
    Ding, Z. J.
    SCANNING MICROSCOPIES 2013: ADVANCED MICROSCOPY TECHNOLOGIES FOR DEFENSE, HOMELAND SECURITY, FORENSIC, LIFE, ENVIRONMENTAL, AND INDUSTRIAL SCIENCES, 2013, 8729
  • [34] Monte Carlo simulation of gold nanoparticles for X-ray enhancement application
    Dheyab, Mohammed Ali
    Aziz, Azlan Abdul
    Rahman, Azhar Abdul
    Ashour, Nabeel Ibrahim
    Musa, Ahmed Sadeq
    Braim, Farhank Saber
    Jameel, Mahmood S.
    BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2023, 1867 (04):
  • [35] Monte Carlo Simulation of Laboratory X-Ray Grating Interferometry Setups
    Tessarini, S.
    Fix, M.
    Volken, W.
    Frei, D.
    Manser, P.
    Vila Comamala, J.
    Stampanoni, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E543 - E543
  • [36] Monte Carlo Simulation of an X-Ray Pixel Beam Microirradiation System
    Schreiber, E. C.
    Chang, S. X.
    RADIATION RESEARCH, 2009, 171 (03) : 332 - 341
  • [37] Monte Carlo simulation of x-ray emission by kilovolt electron bombardment
    Acosta, E.
    Llovet, X.
    Coleoni, E.
    Riveros, J.A.
    Salvat, F.
    Journal of Applied Physics, 1998, 83 (11 pt 1):
  • [38] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [39] X-RAY DOSE ESTIMATION FROM CATHODE RAY TUBE MONITORS BY MONTE CARLO CALCULATION
    Khaledi, Navid
    Arbabi, Azim
    Dabaghi, Moloud
    HEALTH PHYSICS, 2015, 108 (04): : 401 - 406
  • [40] A Monte Carlo ray-tracing simulation of coherent X-ray diffractive imaging
    Fevola, Giovanni
    Knudsen, Erik Bergback
    Ramos, Tiago
    Carbone, Dina
    Andreasen, Jens Wenzel
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 (134-145) : 134 - 145