A Comparison of Cervical Spine Motion During Orotracheal Intubation with the Trachlight® or the Flexible Fiberoptic Bronchoscope

被引:17
|
作者
Houde, Bryan J. [1 ]
Williams, Stephan R. [1 ]
Cadrin-Chenevert, Alexandre [2 ]
Guilbert, Francois [2 ]
Drolet, Pierre [3 ]
机构
[1] Univ Montreal, Ctr Hosp, Hop Notre Dame de Bon Secours, Dept Anesthesiol, Montreal, PQ H2L 4M1, Canada
[2] Univ Montreal, Ctr Hosp, Hop Notre Dame de Bon Secours, Dept Radiol, Montreal, PQ H2L 4M1, Canada
[3] Hop Maison Neuve Rosemont, Dept Anesthesiol, Montreal, PQ H1T 2M4, Canada
来源
ANESTHESIA AND ANALGESIA | 2009年 / 108卷 / 05期
关键词
WILLIAMS-AIRWAY-INTUBATOR; IN-LINE STABILIZATION; TRACHEAL INTUBATION; DIFFICULT AIRWAY; DIRECT LARYNGOSCOPY; HUMAN CADAVERS; MANAGEMENT; ANESTHESIOLOGISTS; INSTABILITY; MANEUVERS;
D O I
10.1213/ane.0b013e31819c60a1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Tracheal intubation of an unstable cervical spine (c-spine) patient with the flexible fiberoptic bronchoscope (FOB) is thought to minimize c-spine movement but may be technically difficult in certain patients. Intubation using a luminous stylet, such as the Trachlight (R) (TL), also produces minimal motion of the c-spine and may be an interesting alternative technique for patients with an unstable c-spine. In this study, we compared the cervical motion caused by the TL and the FOB during intubation. METHODS: Twenty patients with a normal c-spine undergoing general anesthesia, including neuromuscular blockade, for a neuroradiologic intervention were included in a prospective, randomized, controlled, nonblinded, crossover trial. Each patient was tracheally intubated sequentially with the TL and the FOB in a randomized order. Manual in-line stabilization was applied by an assistant during intubation. The motions produced by intubation from the occiput (C0) to C5 were recorded in the sagittal plane using continuous cinefluoroscopy. For movement analysis, the recordings were divided into four stages: "baseline" before intubation began; "introduction" of the intubation device; "intubation" (passage of the tube through the vocal cords); and "removal" of the device. For each intubating device, the average maximal segmental motion observed in every patient at any stage or cervical segment was calculated and compared using Student's t-test. The time required to intubate with each device was also compared. RESULTS: There was no significant difference in the mean maximum segmental motion produced during intubation with the TL versus the FOB (12 degrees +/- 6 degrees vs 11 degrees +/- 5 degrees; P = 0.5). Segmental movements occurred predominantly at the C0-1 and C1-2 levels, and maximal movements were observed during the introduction stage in 18/20 patients for both devices. Intubation took less time with the TL (34 17 vs 60 +/- 15s, P < 0.001). CONCLUSION: In patients under general anesthesia with neuromuscular blockade and manual in-line stabilization, we found no difference in the segmental c-spine motion produced during endotracheal intubation using the FOB and the TL.
引用
收藏
页码:1638 / 1643
页数:6
相关论文
共 50 条
  • [31] OROTRACHEAL INTUBATION AND POTENTIAL CERVICAL-SPINE INJURY - REPLY
    MAJERNICK, TG
    ANNALS OF EMERGENCY MEDICINE, 1987, 16 (03) : 374 - 374
  • [32] Comparison of vocal cord view between neutral and sniffing position during orotracheal intubation using fiberoptic bronchoscope: a prospective, randomized cross over study
    Park, Sanghee
    Lee, Hyung Gon
    Choi, Jeong Il
    Lee, Seongheon
    Jang, Eun-A
    Bae, Hong-Beom
    Rhee, Jeeyun
    Yang, Hyung Chae
    Jeong, Seongtae
    BMC ANESTHESIOLOGY, 2019, 19 (1)
  • [33] A comparison of Disposcope endoscope and Fiberoptic bronchoscope during awake orotracheal intubation in obese patients with anticipated difficult airway: a prospective, randomized and controlled clinical trial
    Liu, Zhuo
    Zhao, Li
    Jia, Qianqian
    Liang, Shujuan
    Yang, Xiaochun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (09): : 9654 - 9661
  • [34] Markedly displaced arytenoid cartilage during fiberoptic orotracheal intubation
    Aoyama, K
    Takenaka, I
    ANESTHESIOLOGY, 2006, 104 (02) : 378 - 379
  • [35] Comparison of Flexiblade™ and Macintosh laryngoscopes: cervical extension angles during orotracheal intubation
    Uzun, S.
    Erden, I. A.
    Pamuk, A. G.
    Yavuz, K.
    Cekirge, S.
    Aypar, Ue.
    ANAESTHESIA, 2010, 65 (07) : 692 - 696
  • [36] COMPARISON OF ORTHODOX WITH FIBEROPTIC OROTRACHEAL INTUBATION UNDER TOTAL IV ANESTHESIA
    SCHAEFER, HG
    MARSCH, SCU
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 66 (05) : 608 - 610
  • [37] Cervical spine motion: a fluoroscopic comparison between Airtraq laryngoscope with fiberoptic bronchoscope and Macintosh laryngoscope - a cross over randomized controlled study
    Tumu, Dinesh Parashar
    Mane, Rajesh
    Patil, Manjunath C.
    Shetty, Guruprasad
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 477 - 479
  • [38] A COMPARISON OF FIBEROPTIC OROTRACHEAL INTUBATION USING 2 DIFFERENT INTUBATING CONDUITS
    HAGBERG, C
    ABRAMSON, D
    CHELLY, J
    ANESTHESIOLOGY, 1995, 83 (3A) : A1220 - A1220
  • [39] THE EFFECT OF AXIAL TRACTION DURING OROTRACHEAL INTUBATION OF THE TRAUMA VICTIM WITH AN UNSTABLE CERVICAL-SPINE
    BIVINS, HG
    FORD, S
    BEZMALINOVIC, Z
    PRICE, HM
    WILLIAMS, JL
    ANNALS OF EMERGENCY MEDICINE, 1988, 17 (01) : 25 - 29
  • [40] Cervical spine movements during laryngoscopy and orotracheal intubation: a systematic review and meta-analysis
    Broenstrup Correa, Jaqueline Betina
    Felice, Vinicius Brenner
    Sbruzzi, Graciele
    Friedman, Gilberto
    EMERGENCY MEDICINE JOURNAL, 2023, 40 (04) : 300 - 307