A Comparison of Cervical Spine Motion During Orotracheal Intubation with the Trachlight® or the Flexible Fiberoptic Bronchoscope

被引:17
|
作者
Houde, Bryan J. [1 ]
Williams, Stephan R. [1 ]
Cadrin-Chenevert, Alexandre [2 ]
Guilbert, Francois [2 ]
Drolet, Pierre [3 ]
机构
[1] Univ Montreal, Ctr Hosp, Hop Notre Dame de Bon Secours, Dept Anesthesiol, Montreal, PQ H2L 4M1, Canada
[2] Univ Montreal, Ctr Hosp, Hop Notre Dame de Bon Secours, Dept Radiol, Montreal, PQ H2L 4M1, Canada
[3] Hop Maison Neuve Rosemont, Dept Anesthesiol, Montreal, PQ H1T 2M4, Canada
来源
ANESTHESIA AND ANALGESIA | 2009年 / 108卷 / 05期
关键词
WILLIAMS-AIRWAY-INTUBATOR; IN-LINE STABILIZATION; TRACHEAL INTUBATION; DIFFICULT AIRWAY; DIRECT LARYNGOSCOPY; HUMAN CADAVERS; MANAGEMENT; ANESTHESIOLOGISTS; INSTABILITY; MANEUVERS;
D O I
10.1213/ane.0b013e31819c60a1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Tracheal intubation of an unstable cervical spine (c-spine) patient with the flexible fiberoptic bronchoscope (FOB) is thought to minimize c-spine movement but may be technically difficult in certain patients. Intubation using a luminous stylet, such as the Trachlight (R) (TL), also produces minimal motion of the c-spine and may be an interesting alternative technique for patients with an unstable c-spine. In this study, we compared the cervical motion caused by the TL and the FOB during intubation. METHODS: Twenty patients with a normal c-spine undergoing general anesthesia, including neuromuscular blockade, for a neuroradiologic intervention were included in a prospective, randomized, controlled, nonblinded, crossover trial. Each patient was tracheally intubated sequentially with the TL and the FOB in a randomized order. Manual in-line stabilization was applied by an assistant during intubation. The motions produced by intubation from the occiput (C0) to C5 were recorded in the sagittal plane using continuous cinefluoroscopy. For movement analysis, the recordings were divided into four stages: "baseline" before intubation began; "introduction" of the intubation device; "intubation" (passage of the tube through the vocal cords); and "removal" of the device. For each intubating device, the average maximal segmental motion observed in every patient at any stage or cervical segment was calculated and compared using Student's t-test. The time required to intubate with each device was also compared. RESULTS: There was no significant difference in the mean maximum segmental motion produced during intubation with the TL versus the FOB (12 degrees +/- 6 degrees vs 11 degrees +/- 5 degrees; P = 0.5). Segmental movements occurred predominantly at the C0-1 and C1-2 levels, and maximal movements were observed during the introduction stage in 18/20 patients for both devices. Intubation took less time with the TL (34 17 vs 60 +/- 15s, P < 0.001). CONCLUSION: In patients under general anesthesia with neuromuscular blockade and manual in-line stabilization, we found no difference in the segmental c-spine motion produced during endotracheal intubation using the FOB and the TL.
引用
收藏
页码:1638 / 1643
页数:6
相关论文
共 50 条
  • [21] Transillumination-assisted orotracheal intubation: a comparison of the Bonfils fibrescope and the lightwand (Trachlight)
    Sui, J. -H.
    Mao, P.
    Liu, J. -H.
    Tong, S. -Y.
    Wei, L. -X.
    Yang, D.
    Deng, X. -M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2012, 56 (05) : 565 - 570
  • [22] OROTRACHEAL INTUBATION AND POTENTIAL CERVICAL-SPINE INJURY
    WALLS, RM
    ANNALS OF EMERGENCY MEDICINE, 1987, 16 (03) : 373 - 373
  • [23] Comparison of haemodynamic responses to orotracheal intubation in anaesthetised and paralysed patients with simulated cervical spine injury: Airtraq® video laryngoscope versus fibreoptic bronchoscope
    Pillai, Ajith Kumar
    Muhamed, Shiyad
    Giri, Manu
    Shenoy, Kailasnath
    Mathew, Shaji
    Dugappa, Arunkumar Handittu
    Rahiman, Ramzi Aboo Abdul
    SRI LANKAN JOURNAL OF ANAESTHESIOLOGY, 2019, 27 (02): : 145 - 150
  • [24] FIBEROPTIC INTUBATION AND CERVICAL-SPINE PROBLEMS
    BALL, D
    ANAESTHESIA, 1994, 49 (08) : 737 - 738
  • [25] Continuous mask ventilation during intubation by fiberoptic bronchoscope
    Wang, L.
    Liu, J. H.
    Deng, X. M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2017, 61 (04) : 459 - 459
  • [26] Comparison of intubation times using a manikin with an immobilized cervical spine: Macintosh laryngoscope vs. GlideScope vs. fiberoptic bronchoscope
    Ko, Jung-In
    Ha, Sang Ook
    Koo, Min Seok
    Kwon, Miyoung
    Kim, Jieun
    Jeon, Jin
    Park, So Hee
    Shim, Sangwoo
    Chang, Youjin
    Park, Taejin
    CLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE, 2015, 2 (04): : 244 - 249
  • [27] Comparison of haemodynamic responses to orotracheal intubation with GlideScope® videolaryngoscope and fibreoptic bronchoscope
    Xue, FS
    Zhang, GH
    Li, XY
    Sun, HT
    Li, P
    Sun, HY
    Xu, YC
    Liu, Y
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (06) : 522 - 526
  • [28] CERVICAL-SPINE MOVEMENT DURING OROTRACHEAL INTUBATION - COMPARISON OF THE BELSCOPE-BLADE AND MACINTOSH-BLADE
    GAJRAJ, NM
    CHASON, DP
    SHEARER, VE
    ANAESTHESIA, 1994, 49 (09) : 772 - 774
  • [29] Cervical spine motion with direct laryngoscopy and orotracheal intubation: An in vivo cinefluoroscopic study of subjects without cervical abnormality
    Sawin, PD
    Todd, MM
    Traynelis, VC
    Farrell, SB
    Nader, A
    Sato, Y
    Clausen, JD
    Goel, VK
    ANESTHESIOLOGY, 1996, 85 (01) : 26 - 36
  • [30] Comparison of vocal cord view between neutral and sniffing position during orotracheal intubation using fiberoptic bronchoscope: a prospective, randomized cross over study
    Sanghee Park
    Hyung Gon Lee
    Jeong Il Choi
    Seongheon Lee
    Eun-A Jang
    Hong-Beom Bae
    Jeeyun Rhee
    Hyung Chae Yang
    Seongtae Jeong
    BMC Anesthesiology, 19