Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification

被引:174
|
作者
Hamilton, Gavin [1 ]
Middleton, Michael S. [1 ]
Bydder, Mark [1 ]
Yokoo, Takeshi [1 ]
Schwimmer, Jeffrey B. [2 ]
Kono, Yuko [3 ]
Patton, Heather M. [3 ]
Lavine, Joel E. [2 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Div Gastroenterol Hepatol & Nutr, Dept Pediat, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Dept Med, San Diego, CA 92103 USA
关键词
liver fat quantification; magnetic resonance spectroscopy; PRESS; STEAM; IN-VIVO; PROTON SPECTROSCOPY; QUANTITATIVE-ANALYSIS; INSULIN-RESISTANCE; STIMULATED ECHOES; H-1; SPECTROSCOPY; MR SPECTROSCOPY; BRAIN MOTION; TRIGLYCERIDE; METABOLITES;
D O I
10.1002/jmri.21809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare PRESS and STEAM MR spectroscopy for assessment of liver fat in human subjects. Materials and Methods: Single-voxel (20 x 20 x 20 mm) PRESS and STEAM spectra were obtained at 1.5T in 49 human subjects with known or suspected fatty liver disease. PRESS and STEAM sequences were obtained with fixed TR (1500 msec) and different TE (five PRESS spectra between TE 30-70 msec, five STEAM spectra between TE 20-60 msec). Spectra were quantified and T2 and T2-corrected peak area were calculated by different techniques. The values were compared for PRESS and STEAM. Results: Water T2 values from PRESS and STEAM were not significantly different (P = 0.33). Fat peak T2s were 25%-50% shorter on PRESS than on STEAM (P < 0.02 for all comparisons) and there was no correlation between T2s of individual peaks. PRESS systematically overestimated the relative fat peak areas (by 7%-263%) compared to STEAM (P < 0.005 for all comparisons). The peak area given by PRESS was more dependent on the T2-correction technique than STEAM. Conclusion: Measured liver fat depends on the MRS sequence used. Compared to STEAM, PRESS underestimates T2 values of fat, overestimates fat fraction, and provides a less consistent fat fraction estimate, probably due to J coupling effects.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 50 条
  • [1] Quantification of liver fat infiltration by magnetic resonance
    Herrera, Rodrigo
    Penaloza, Francisco
    Arrietal, Cristobal
    Zacconi, Flavia
    Saavedra, Victor
    Saavedra, Carla
    Branes, Cecilia
    Hack, Thomas
    Uribe, Sergio
    REVISTA MEDICA DE CHILE, 2019, 147 (07) : 821 - 827
  • [2] Quantification of Liver Fat with Magnetic Resonance Imaging
    Reeder, Scott B.
    Sirlin, Claude B.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2010, 18 (03) : 337 - +
  • [3] QUANTIFICATION OF LIVER FAT USING MAGNETIC-RESONANCE SPECTROSCOPY
    THOMSEN, C
    BECKER, U
    WINKLER, K
    CHRISTOFFERSEN, P
    JENSEN, M
    HENRIKSEN, O
    MAGNETIC RESONANCE IMAGING, 1994, 12 (03) : 487 - 495
  • [4] Magnetic Resonance Fat Quantification in Living Donor Liver Transplantation
    Chiang, H. -J.
    Lin, L. -H.
    Li, C. -W.
    Lin, C. -C.
    Chiang, H. -W.
    Huang, T. -L.
    Chen, C. -L.
    Cheng, Y. -F.
    TRANSPLANTATION PROCEEDINGS, 2014, 46 (03) : 666 - 668
  • [5] Utility of magnetic resonance proton density fat fraction technique in quantification of liver fat in living donors for liver transplantation
    Sherif, Fatma Mohamed
    Elmogy, Sabry Alameldeen
    Abd EL-wahab, Rihame Mohamed
    Wahab, Mohamed Abdel
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01):
  • [6] Utility of magnetic resonance proton density fat fraction technique in quantification of liver fat in living donors for liver transplantation
    Fatma Mohamed Sherif
    Sabry Alameldeen Elmogy
    Rihame Mohamed Abd EL-wahab
    Mohamed Abdel Wahab
    Egyptian Journal of Radiology and Nuclear Medicine, 50
  • [7] Magnetic Resonance Techniques for Fat Quantification in Obesity
    Hu, Houchun Harry
    2012 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA ASC), 2012,
  • [8] A Novel Portable Unilateral Magnetic Resonance Magnet for Noninvasive Quantification of Human Liver Fat
    Lu, Rongsheng
    Jiang, Xiaowen
    Zhang, Jinxiang
    Hu, Jianxiong
    Chen, Xiao
    Wu, Ziyue
    Qian, Zhiyong
    Luo, Hai
    Ni, Zhonghua
    Yi, Hong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [9] Quantification of liver fat by proton magnetic resonance spectroscopy in 271 subjects with and without the metabolic syndrome
    Kotronen, A.
    Westerbacka, J.
    Bergholm, R.
    Pietilainen, K. H.
    Juurinen, L.
    Yki-Jarvinen, H.
    ATHEROSCLEROSIS SUPPLEMENTS, 2007, 8 (01) : 171 - 171
  • [10] PROSPECTIVE EVALUATION OF THE ACCURACY OF MAGNETIC RESONANCE FOR FAT QUANTIFICATION IN PEDIATRIC NONALCOHOLIC FATTY LIVER DISEASE
    Pacifico, L.
    Di Martino, M.
    Panebianco, V.
    Martino, F.
    Bezzi, M.
    Catalano, C.
    Poggiogalle, E.
    Chiesa, C.
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2010, 50 : E15 - E16