A Novel Portable Unilateral Magnetic Resonance Magnet for Noninvasive Quantification of Human Liver Fat

被引:0
|
作者
Lu, Rongsheng [1 ]
Jiang, Xiaowen [1 ]
Zhang, Jinxiang [1 ]
Hu, Jianxiong [2 ]
Chen, Xiao [2 ]
Wu, Ziyue [2 ]
Qian, Zhiyong
Luo, Hai [2 ]
Ni, Zhonghua [1 ]
Yi, Hong [1 ]
机构
[1] Southeast Univ, Sch Mech Engn, Jiangsu Key Lab Design & Manufacture Micronano Bio, Nanjing 211189, Peoples R China
[2] Wuxi Marvel Stone Healthcare Co Ltd, Wuxi 214000, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; Fats; Nuclear magnetic resonance; Magnetic fields; Magnetic field measurement; Liver diseases; Radio frequency; Liver fat quantification; magnetic resonance; noninvasive measurement; relaxometry; single-sided magnet; DISEASE; CONNECTIONS; ULTRASOUND; STEATOSIS; OBESITY;
D O I
10.1109/TIM.2023.3268480
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fatty liver disease has become one of the common liver diseases seriously affecting people's health and quality of life. Existing means to quantify liver fat content are usually invasive and high-cost. Our research aims to design a single-sided magnet to develop a low-cost, noninvasive, and lightweight unilateral magnetic resonance (UMR) system that can satisfy the needs for fatty liver screening and diagnosis. A novel single-sided permanent magnet with a pear-shaped magnetic field iso-surface was designed to avoid the excitation of subcutaneous tissue in the human body. The weight of the magnet was optimized to 12.9 kg, and the mean magnetic field strength of the region of interest (ROI) was 0.07 T. The radio frequency (RF) coil set, the pulse sequence, and the modeling method for measuring proton density fat fraction (PDFF) were also introduced. Experiments for phantoms and volunteers were carried out by the UMR system to verify the performance of detection. The phantom detection results show that the UMR system can effectively avoid the influence of the subcutaneous tissue part on PDFF detection, with reasonable accuracy (around 5% fat fraction error) and robustness (within 10% relative error). Compared with a conventional magnetic resonance imaging (MRI) scanner, measurement results of volunteers (around 3% fat fraction error) show the effectiveness of the UMR system for screening fatty liver diseases. The UMR system developed based on the proposed portable single-sided magnet could be a low-cost and reliable diagnostic tool for noninvasive fatty liver disease diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quantification of liver fat infiltration by magnetic resonance
    Herrera, Rodrigo
    Penaloza, Francisco
    Arrietal, Cristobal
    Zacconi, Flavia
    Saavedra, Victor
    Saavedra, Carla
    Branes, Cecilia
    Hack, Thomas
    Uribe, Sergio
    REVISTA MEDICA DE CHILE, 2019, 147 (07) : 821 - 827
  • [2] Quantification of Liver Fat with Magnetic Resonance Imaging
    Reeder, Scott B.
    Sirlin, Claude B.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2010, 18 (03) : 337 - +
  • [3] Radiofrequency coil design for improving human liver fat quantification in a portable single-side magnetic resonance system
    Yang, Shiwei
    Chen, Xiao
    Chen, Suen
    Chen, Hao
    Zhao, Yue
    Wu, Ziyue
    Luo, Hai
    Zhang, Zhiyong
    NMR IN BIOMEDICINE, 2023, 36 (05)
  • [4] QUANTIFICATION OF LIVER FAT USING MAGNETIC-RESONANCE SPECTROSCOPY
    THOMSEN, C
    BECKER, U
    WINKLER, K
    CHRISTOFFERSEN, P
    JENSEN, M
    HENRIKSEN, O
    MAGNETIC RESONANCE IMAGING, 1994, 12 (03) : 487 - 495
  • [5] Magnetic Resonance Fat Quantification in Living Donor Liver Transplantation
    Chiang, H. -J.
    Lin, L. -H.
    Li, C. -W.
    Lin, C. -C.
    Chiang, H. -W.
    Huang, T. -L.
    Chen, C. -L.
    Cheng, Y. -F.
    TRANSPLANTATION PROCEEDINGS, 2014, 46 (03) : 666 - 668
  • [6] Magnet Array for a Portable Magnetic Resonance Imaging System
    Ren, Zhi Hua
    Marechal, Luc
    Luo, Wan
    Su, Jiasheng
    Huang, Shao Ying
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2015, : 92 - 95
  • [7] Design and analysis of the novel test tube magnet as a device for portable nuclear magnetic resonance
    Chen, Jizhong
    Xu, Chunyan
    IEEE TRANSACTIONS ON MAGNETICS, 2007, 43 (09) : 3555 - 3557
  • [8] Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification
    Hamilton, Gavin
    Middleton, Michael S.
    Bydder, Mark
    Yokoo, Takeshi
    Schwimmer, Jeffrey B.
    Kono, Yuko
    Patton, Heather M.
    Lavine, Joel E.
    Sirlin, Claude B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) : 145 - 152
  • [9] Utility of magnetic resonance proton density fat fraction technique in quantification of liver fat in living donors for liver transplantation
    Sherif, Fatma Mohamed
    Elmogy, Sabry Alameldeen
    Abd EL-wahab, Rihame Mohamed
    Wahab, Mohamed Abdel
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01):
  • [10] Utility of magnetic resonance proton density fat fraction technique in quantification of liver fat in living donors for liver transplantation
    Fatma Mohamed Sherif
    Sabry Alameldeen Elmogy
    Rihame Mohamed Abd EL-wahab
    Mohamed Abdel Wahab
    Egyptian Journal of Radiology and Nuclear Medicine, 50