Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification

被引:174
|
作者
Hamilton, Gavin [1 ]
Middleton, Michael S. [1 ]
Bydder, Mark [1 ]
Yokoo, Takeshi [1 ]
Schwimmer, Jeffrey B. [2 ]
Kono, Yuko [3 ]
Patton, Heather M. [3 ]
Lavine, Joel E. [2 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Div Gastroenterol Hepatol & Nutr, Dept Pediat, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Dept Med, San Diego, CA 92103 USA
关键词
liver fat quantification; magnetic resonance spectroscopy; PRESS; STEAM; IN-VIVO; PROTON SPECTROSCOPY; QUANTITATIVE-ANALYSIS; INSULIN-RESISTANCE; STIMULATED ECHOES; H-1; SPECTROSCOPY; MR SPECTROSCOPY; BRAIN MOTION; TRIGLYCERIDE; METABOLITES;
D O I
10.1002/jmri.21809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare PRESS and STEAM MR spectroscopy for assessment of liver fat in human subjects. Materials and Methods: Single-voxel (20 x 20 x 20 mm) PRESS and STEAM spectra were obtained at 1.5T in 49 human subjects with known or suspected fatty liver disease. PRESS and STEAM sequences were obtained with fixed TR (1500 msec) and different TE (five PRESS spectra between TE 30-70 msec, five STEAM spectra between TE 20-60 msec). Spectra were quantified and T2 and T2-corrected peak area were calculated by different techniques. The values were compared for PRESS and STEAM. Results: Water T2 values from PRESS and STEAM were not significantly different (P = 0.33). Fat peak T2s were 25%-50% shorter on PRESS than on STEAM (P < 0.02 for all comparisons) and there was no correlation between T2s of individual peaks. PRESS systematically overestimated the relative fat peak areas (by 7%-263%) compared to STEAM (P < 0.005 for all comparisons). The peak area given by PRESS was more dependent on the T2-correction technique than STEAM. Conclusion: Measured liver fat depends on the MRS sequence used. Compared to STEAM, PRESS underestimates T2 values of fat, overestimates fat fraction, and provides a less consistent fat fraction estimate, probably due to J coupling effects.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 50 条
  • [31] Standardization of the quantification of iron concentration in the liver by magnetic resonance imaging
    Alustiza, J. M.
    Emparanza, J. I.
    Aldazabalc, P.
    Garrido, A.
    Garcia, N.
    Salvador, E.
    San Vicente, M.
    RADIOLOGIA, 2012, 54 (02): : 149 - 154
  • [32] Quantification of muscle, subcutaneous fat and intermuscular fat in pig carcasses and cuts by magnetic resonance imaging
    Monziols, M
    Collewet, G
    Bonneau, M
    Mariette, F
    Davenel, A
    Kouba, M
    MEAT SCIENCE, 2006, 72 (01) : 146 - 154
  • [33] Quantification of the Fat Fraction in Bone Marrow using Fat-Water Magnetic Resonance Imaging
    Salaz-Ramirez, M.
    Tran-Gia, J.
    Kesenheimer, C.
    Weng, A. M.
    Koestler, H.
    Lassmann, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S805 - S806
  • [34] Comparison of magnetic resonance spectroscopy, proton density fat fraction and histological analysis in the quantification of liver steatosis in children and adolescents
    Michele Di Martino
    Lucia Pacifico
    Mario Bezzi
    Rossella Di Miscio
    Beatrice Sacconi
    Claudio Chiesa
    Carlo Catalano
    World Journal of Gastroenterology, 2016, 22 (39) : 8812 - 8819
  • [35] Radiofrequency coil design for improving human liver fat quantification in a portable single-side magnetic resonance system
    Yang, Shiwei
    Chen, Xiao
    Chen, Suen
    Chen, Hao
    Zhao, Yue
    Wu, Ziyue
    Luo, Hai
    Zhang, Zhiyong
    NMR IN BIOMEDICINE, 2023, 36 (05)
  • [36] A 3D Quantification Technique for Liver Fat Fraction Distribution Analysis Using Dixon Magnetic Resonance Imaging
    Zhao, Fan
    Zhang, Genming
    Tan, Zhongjian
    Liang, Tengxiao
    Xing, Fangliang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (200):
  • [37] Comparison of magnetic resonance spectroscopy, proton density fat fraction and histological analysis in the quantification of liver steatosis in children and adolescents
    Di Martino, Michele
    Pacifico, Lucia
    Bezzi, Mario
    Di Miscio, Rossella
    Sacconi, Beatrice
    Chiesa, Claudio
    Catalano, Carlo
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (39) : 8812 - 8819
  • [38] Effect of colesevelam on liver fat quantified by magnetic resonance in nonalcoholic steatohepatitis: A randomized controlled trial
    Thuy-Anh Le
    Chen, Joshua
    Changchien, Christopher
    Peterson, Michael R.
    Kono, Yuko
    Patton, Heather
    Cohen, Benjamin L.
    Brenner, David
    Sirlin, Claude
    Loomba, Rohit
    HEPATOLOGY, 2012, 56 (03) : 922 - 932
  • [39] Quantitative Assessment of Liver Fat with Magnetic Resonance Imaging and Spectroscopy
    Reeder, Scott B.
    Cruite, Irene
    Hamilton, Gavin
    Sirlin, Claude B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) : 729 - 749
  • [40] Liver fat content determined by magnetic resonance imaging and spectroscopy
    Springer, Fabian
    Machann, Juergen
    Claussen, Claus D.
    Schick, Fritz
    Schwenzer, Nina F.
    WORLD JOURNAL OF GASTROENTEROLOGY, 2010, 16 (13) : 1560 - 1566