A Novel Real-Time Loop-Mediated Isothermal Amplification Combined with Immunomagnetic Beads Separation and Ethidium Bromide Monoazide Treatment for Rapid and Ultrasensitive Detection of Viable Escherichia coli O157:H7 in Milk

被引:14
|
作者
Chen, Hu [1 ]
Li, Ya-Ke [1 ]
Zhang, Tian-Tian [1 ]
Bi, Yan [1 ]
Shu, Mei [1 ]
Zhong, Chan [1 ]
Tang, Kai-Jie [1 ]
Wu, Guo-Ping [1 ]
机构
[1] Jiangxi Agr Univ, Coll Food Sci & Engn, Nanchang 330045, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
E. coli O157:H7; Real-time loop-mediated isothermal amplification (Rti-LAMP); Immunomagnetic beads separation (IMS); Gly-HCl elution; Ethidium bromide monoazide (EMA); MULTIPLEX PCR ASSAY; LISTERIA-MONOCYTOGENES; EFFICIENT ENRICHMENT; PMA; SALMONELLA; LAMP; BACTERIA; CELLS; DNA;
D O I
10.1007/s12161-020-01932-y
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this study, a real-time loop-mediated isothermal amplification (Rti-LAMP) combined with immunomagnetic beads separation (IMS) and ethidium bromide monoazide (EMA) treatment was developed for the rapid and ultrasensitive detection of viable Escherichia coli (E. coli) O157:H7 in milk without enrichment. Polyclonal antibodies against E. coli O157:H7 flagellum and specific immunomagnetic beads (IMBs) were prepared. The capture efficiency of target bacteria was more than 95% by adding 50 mu L of prepared IMBs into 1 mL of E. coli sample for incubation at 37 degrees C for 20 min. Then, Gly-HCl buffer (0.2 M, pH 2.2) was a key to the effective eluting and separating of bacteria from IMB-bacterial complexes. The eluted bacteria were resuspended with 20 mu L TZ lysing solution and boiled at 99.5 degrees C for 10 min, as a DNA template of Rti-LAMP. The development of IMS-Rti-LAMP assay could specifically detect viable E. coli O157:H7 as low as 2.7 CFU/mL in pure culture. Furthermore, the optimum volume for detection of E. coli O157:H7 in milk was 1 mL of the sample by IMS-Rti-LAMP assay. Before Gly-HCl elution, 4 mu g/mL of EMA was used to treat bacterial cells which significantly inhibited DNA amplification derived from dead cells in Rti-LAMP. The limit of detection (LOD) of viable E. coli O157:H7 in milk was 6 CFU/mL by the IMS-EMA-Rti-LAMP, and the whole assay could be completed in 4 h. The development of IMS-EMA-Rti-LAMP assay was a rapid, ultrasensitive, and specific detection of viable E. coli O157:H7 in milk without enrichment.
引用
收藏
页码:944 / 956
页数:13
相关论文
共 50 条
  • [31] Rapid Detection of Escherichia coli O157:H7 by Loop-Mediated Isothermal Amplification Coupled with a Lateral Flow Assay Targeting the z3276 Genetic Marker
    Xuefeng Xia
    Bicheng Zhang
    Jing Wang
    Bin Li
    Kongwang He
    Xuehan Zhang
    Food Analytical Methods, 2022, 15 : 908 - 916
  • [32] A Novel SDS Rinse and Immunomagnetic Beads Separation Combined with Real-Time Loop-Mediated Isothermal Amplification for Rapid and Sensitive Detection of Salmonella in Ready-to-Eat Duck Meat
    Yan Bi
    Mei Shu
    Chan Zhong
    Sheng-Yan Li
    Ya-Ke Li
    Huan-Huan Yang
    Guo-Ping Wu
    Food Analytical Methods, 2020, 13 : 1166 - 1175
  • [33] Rapid Detection of Escherichia coli O157:H7 by Loop-Mediated Isothermal Amplification Coupled with a Lateral Flow Assay Targeting the z3276 Genetic Marker
    Xia, Xuefeng
    Zhang, Bicheng
    Wang, Jing
    Li, Bin
    He, Kongwang
    Zhang, Xuehan
    FOOD ANALYTICAL METHODS, 2022, 15 (04) : 908 - 916
  • [34] One real-time fluorescent loop-mediated isothermal amplification combined with propidium monoazide for detection of viable vibrio parahaemolyticus in seafood
    Yu H.
    Fang J.
    Ma B.
    Li J.
    Zhang M.
    American Journal of Biochemistry and Biotechnology, 2019, 15 (02): : 91 - 100
  • [35] RAPID AND SIMPLE DETECTION OF SHIGA TOXIN-PRODUCING ESCHERICHIA COLI (STEC) O157:H7 AND STEC NON-O157:H7 SEROTYPES USING COLORIMETRIC LOOP-MEDIATED ISOTHERMAL AMPLIFICATION ASSAY
    Nawattanapaibool, Namfon
    Saiyudthong, Soithong
    Changsen, Chartchai
    Buates, Sureemas
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2021, 52 (02) : 240 - 258
  • [36] Loop mediated isothermal amplification as a molecular diagnostic assay: Application and evaluation for detection of Enterohaemorrhagic Escherichia coli (O157:H7)
    Yinur, Degisew
    Moges, Biniam
    Hassen, Aliyi
    Tessema, Tesfaye Sisay
    PRACTICAL LABORATORY MEDICINE, 2023, 37
  • [37] Rapid and simultaneous quantitation of Escherichia coli O157:H7, Salmonella, and Shigella in ground beef by multiplex real-time PCR and immunomagnetic separation
    Wang, Luxin
    Li, Yong
    Mustapha, Azlin
    JOURNAL OF FOOD PROTECTION, 2007, 70 (06) : 1366 - 1372
  • [38] Rapid Detection of Escherichia coli O157:H7 in Fresh Lettuce Based on Localized Surface Plasmon Resonance Combined with Immunomagnetic Separation
    Lee, Nari
    Choi, Sung-Wook
    Chang, Hyun-Joo
    Chun, Hyang Sook
    JOURNAL OF FOOD PROTECTION, 2018, 81 (05) : 713 - 718
  • [39] An evaluation of immunomagnetic separation-real-time PCR (IMS-RTiPCR) combined assay for rapid and specific detection of Escherichia coli O157:H7 in raw milk and ground beef
    Mercanoglu Taban, Birce
    Aytac, Sait Aykut
    FOOD SCIENCE AND TECHNOLOGY, 2019, 39 (04): : 955 - 961
  • [40] Detection of Viable Vibrio cholerae Cells in Seafood Using a Real-Time Visual Loop-Mediated Isothermal Amplification Combined with Propidium Monoazide
    Zhi, Antong
    Ma, Biao
    Wu, Yingying
    Fang, Jiehong
    Yu, Xiaoping
    Zhang, Mingzhou
    FOOD ANALYTICAL METHODS, 2018, 11 (01) : 99 - 110