A Novel Real-Time Loop-Mediated Isothermal Amplification Combined with Immunomagnetic Beads Separation and Ethidium Bromide Monoazide Treatment for Rapid and Ultrasensitive Detection of Viable Escherichia coli O157:H7 in Milk

被引:14
|
作者
Chen, Hu [1 ]
Li, Ya-Ke [1 ]
Zhang, Tian-Tian [1 ]
Bi, Yan [1 ]
Shu, Mei [1 ]
Zhong, Chan [1 ]
Tang, Kai-Jie [1 ]
Wu, Guo-Ping [1 ]
机构
[1] Jiangxi Agr Univ, Coll Food Sci & Engn, Nanchang 330045, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
E. coli O157:H7; Real-time loop-mediated isothermal amplification (Rti-LAMP); Immunomagnetic beads separation (IMS); Gly-HCl elution; Ethidium bromide monoazide (EMA); MULTIPLEX PCR ASSAY; LISTERIA-MONOCYTOGENES; EFFICIENT ENRICHMENT; PMA; SALMONELLA; LAMP; BACTERIA; CELLS; DNA;
D O I
10.1007/s12161-020-01932-y
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this study, a real-time loop-mediated isothermal amplification (Rti-LAMP) combined with immunomagnetic beads separation (IMS) and ethidium bromide monoazide (EMA) treatment was developed for the rapid and ultrasensitive detection of viable Escherichia coli (E. coli) O157:H7 in milk without enrichment. Polyclonal antibodies against E. coli O157:H7 flagellum and specific immunomagnetic beads (IMBs) were prepared. The capture efficiency of target bacteria was more than 95% by adding 50 mu L of prepared IMBs into 1 mL of E. coli sample for incubation at 37 degrees C for 20 min. Then, Gly-HCl buffer (0.2 M, pH 2.2) was a key to the effective eluting and separating of bacteria from IMB-bacterial complexes. The eluted bacteria were resuspended with 20 mu L TZ lysing solution and boiled at 99.5 degrees C for 10 min, as a DNA template of Rti-LAMP. The development of IMS-Rti-LAMP assay could specifically detect viable E. coli O157:H7 as low as 2.7 CFU/mL in pure culture. Furthermore, the optimum volume for detection of E. coli O157:H7 in milk was 1 mL of the sample by IMS-Rti-LAMP assay. Before Gly-HCl elution, 4 mu g/mL of EMA was used to treat bacterial cells which significantly inhibited DNA amplification derived from dead cells in Rti-LAMP. The limit of detection (LOD) of viable E. coli O157:H7 in milk was 6 CFU/mL by the IMS-EMA-Rti-LAMP, and the whole assay could be completed in 4 h. The development of IMS-EMA-Rti-LAMP assay was a rapid, ultrasensitive, and specific detection of viable E. coli O157:H7 in milk without enrichment.
引用
收藏
页码:944 / 956
页数:13
相关论文
共 50 条
  • [21] Loop-mediated isothermal amplification combined with immunomagnetic separation and propidium monoazide for the specific detection of viable Listeria monocytogenes in milk products, with an internal amplification control
    Roumani, Foteini
    Azinheiro, Sarah
    Carvalho, Joana
    Prado, Marta
    Garrido-Maestu, Alejandro
    FOOD CONTROL, 2021, 125
  • [22] A Bipolar Electrode-Electrochemiluminescence Sensor for Sensitive Detection of Escherichia coli O157:H7 Based on Loop-Mediated Isothermal Amplification
    Qi, Yan
    Wang, Fengyang
    Jiang, Yanjun
    Ji, Lei
    Xiong, Xiaohui
    Liu, Yuanjian
    FOOD ANALYTICAL METHODS, 2025,
  • [23] Rapid and Accurate Detection of Bacteriophage Activity against Escherichia coli O157:H7 by Propidium Monoazide Real-Time PCR
    Liu, Hui
    Niu, Yan D.
    Li, Jinquan
    Stanford, Kim
    McAllister, Tim A.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [24] Quantitative detection of viable but nonculturable state Escherichia coli O157:H7 by ddPCR combined with propidium monoazide
    Pan, Hanxu
    Dong, Kai
    Rao, Lei
    Zhao, Liang
    Wu, Xiaomeng
    Wang, Yongtao
    Liao, Xiaojun
    FOOD CONTROL, 2020, 112
  • [25] Rapid detection of Escherichia coli O157:H7 with multiplex real-time PCR assays
    Jothikumar, N
    Griffiths, MW
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2002, 68 (06) : 3169 - 3171
  • [26] ESTABLISHMENT AND OPTIMIZATION OF COLORIMETRIC LOOP- MEDIATED ISOTHERMAL AMPLIFICATION FOR VISUAL DETECTION OF ESCHERICHIA COLI O157:H7
    Ye, Congxiu
    Yi, Jinling
    Yin, Songchao
    Li, Meirong
    Li, Yanmei
    ACTA MEDICA MEDITERRANEA, 2016, 32 : 1149 - 1153
  • [27] Detection of E. coli O157:H7 in Food Using Automated Immunomagnetic Separation Combined with Real-Time PCR
    Park, Ji Young
    Lim, Min-Cheol
    Park, Kisang
    Ok, Gyeongsik
    Chang, Hyun-Joo
    Lee, Nari
    Park, Tae Jung
    Choi, Sung-Wook
    PROCESSES, 2020, 8 (08)
  • [28] Rapid detection of single viable Escherichia coli O157:H7 cells in milk by flow cytometry
    Liu, Siyuan
    Sui, Zhiwei
    Lin, Jing
    Huo, Nairui
    Yang, Jiayi
    Wang, Bin
    Gu, Shaopeng
    JOURNAL OF FOOD SAFETY, 2019, 39 (04)
  • [29] Rapid and accurate detection of viable Escherichia coli O157:H7 in milk using a combined IMS, sodium deoxycholate, PMA and real-time quantitative PCR process
    Wang, Lijun
    Li, Ping
    Zhang, Zhihong
    Chen, Qi
    Aguilar, Zoraida P.
    Xu, Hengyi
    Yang, Lin
    Xu, Feng
    Lai, Weihua
    Xiong, Yonghua
    Wei, Hua
    FOOD CONTROL, 2014, 36 (01) : 119 - 125
  • [30] A Novel SDS Rinse and Immunomagnetic Beads Separation Combined with Real-Time Loop-Mediated Isothermal Amplification for Rapid and Sensitive Detection of Salmonella in Ready-to-Eat Duck Meat
    Bi, Yan
    Shu, Mei
    Zhong, Chan
    Li, Sheng-Yan
    Li, Ya-Ke
    Yang, Huan-Huan
    Wu, Guo-Ping
    FOOD ANALYTICAL METHODS, 2020, 13 (05) : 1166 - 1175