Measuring Computed Tomography Scanner Variability of Radiomics Features

被引:528
|
作者
Mackin, Dennis [1 ]
Fave, Xenia [1 ,2 ]
Zhang, Lifei [1 ]
Fried, David [1 ,2 ]
Yang, Jinzhong [1 ]
Taylor, Brian [3 ,4 ]
Rodriguez-Rivera, Edgardo [5 ]
Dodge, Cristina [6 ]
Jones, Aaron Kyle [7 ]
Court, Laurence [1 ,7 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Hlth Sci Ctr Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
[3] Michael E DeBakey VA Med Ctr, Res Serv Line & Diagnost & Therapeut Care Line, Houston, TX USA
[4] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[5] Houston Methodist Hosp, Radiat Oncol Dept, Houston, TX USA
[6] Texas Childrens Hosp, Dept Diagnost Imaging, Houston, TX 77030 USA
[7] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
radiomics; image texture; image features; CT; computed tomography; phantom; TEXTURAL FEATURES; CT; IMAGES; REPRODUCIBILITY; CANCER;
D O I
10.1097/RLI.0000000000000180
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The purpose of this study was to determine the significance of interscanner variability in CT image radiomics studies. Materials and Methods We compared the radiomics features calculated for non-small cell lung cancer (NSCLC) tumors from 20 patients with those calculated for 17 scans of a specially designed radiomics phantom. The phantom comprised 10 cartridges, each filled with different materials to produce a wide range of radiomics feature values. The scans were acquired using General Electric, Philips, Siemens, and Toshiba scanners from 4 medical centers using their routine thoracic imaging protocol. The radiomics feature studied included the mean and standard deviations of the CT numbers as well as textures derived from the neighborhood gray-tone difference matrix. To quantify the significance of the interscanner variability, we introduced the metric feature noise. To look for patterns in the scans, we performed hierarchical clustering for each cartridge. Results The mean CT numbers for the 17 CT scans of the phantom cartridges spanned from -864 to 652 Hounsfield units compared with a span of -186 to 35 Hounsfield units for the CT scans of the NSCLC tumors, showing that the phantom's dynamic range includes that of the tumors. The interscanner variability of the feature values depended on both the cartridge material and the feature, and the variability was large relative to the interpatient variability in the NSCLC tumors for some features. The feature interscanner noise was greatest for busyness and least for texture strength. Hierarchical clustering produced different clusters of the phantom scans for each cartridge, although there was some consistent clustering by scanner manufacturer. Conclusions The variability in the values of radiomics features calculated on CT images from different CT scanners can be comparable to the variability in these features found in CT images of NSCLC tumors. These interscanner differences should be considered, and their effects should be minimized in future radiomics studies.
引用
下载
收藏
页码:757 / 765
页数:9
相关论文
共 50 条
  • [31] Effect of scanner type and calcium measure on the re-scan variability of calcium quantity by computed tomography
    Detrano, R
    Anderson, M
    Nelson, J
    Wong, N
    Carr, J
    Bild, D
    CIRCULATION, 2002, 106 (19) : 479 - 479
  • [32] Feature Robustness and Diagnostic Capabilities of Convolutional Neural Networks Against Radiomics Features in Computed Tomography Imaging
    Ziegelmayer, Sebastian
    Reischl, Stefan
    Harder, Felix
    Makowski, Marcus
    Braren, Rickmer
    Gawlitza, Joshua
    INVESTIGATIVE RADIOLOGY, 2022, 57 (03) : 171 - 177
  • [33] Visual Interpretation of Radiomics Features in Filtered Computed Tomography Images during the Portal Phase of Acute Pancreatitis
    He, Wenjing
    Tang, Mingyue
    Jiang, Xian
    Xiao, Bo
    Wei, Jiayi
    Zhao, Yanmei
    Zhu, Yuanzhong
    Chen, Xiaowen
    DISCOVERY MEDICINE, 2024, 36 (183) : 730 - 738
  • [34] The relationship between contrast-enhanced computed tomography radiomics features and mitosis karyorrhexis index in neuroblastoma
    Chen, Xin
    Wang, Haoru
    Xia, Yuwei
    Shi, Feng
    He, Ling
    Liu, Enmei
    DISCOVER ONCOLOGY, 2024, 15 (01)
  • [35] Radiomics features on non-contrast computed tomography predict early enlargement of spontaneous intracerebral hemorrhage
    Li, Hui
    Xie, Yuanliang
    Wang, Xiang
    Chen, Faxiang
    Sun, Jianqing
    Jiang, Xiaoli
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 185
  • [36] Exploratory Radiomics in Computed Tomography Perfusion of Prostate Cancer
    Tanadini-Lang, Stephanie
    Bogowicz, Marta
    Veit-Haibach, Patrick
    Huellner, Martin
    Pauli, Chantal
    Shukla, Vyoma
    Guckenberger, Matthias
    Riesterer, Oliver
    ANTICANCER RESEARCH, 2018, 38 (02) : 685 - 690
  • [37] VARIABILITY OF MANUAL AND COMPUTERIZED METHODS FOR MEASURING CORONAL VERTEBRAL INCLINATION IN COMPUTED TOMOGRAPHY IMAGES
    Vrtovec, Tomaz
    Pernus, Franjo
    Likar, Bostjan
    IMAGE ANALYSIS & STEREOLOGY, 2015, 34 (03): : 199 - 208
  • [38] USING A COMPUTED-TOMOGRAPHY SCANNER FOR NONMEDICAL APPLICATIONS
    CESAREO, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 275 (02): : 420 - 429
  • [39] ANTHROPOMORPHIC PHANTOMS FOR COMPUTED TOMOGRAPHY SCANNER PERFORMANCE EVALUATION
    MCCULLOUGH, EC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (01) : 109 - 112
  • [40] Comparison of Optical Scanner and Computed Tomography Scan Accuracy
    Kritikos, Michaela
    Urminsky, Jan
    Buransky, Ivan
    DIGITIZING PRODUCTION SYSTEMS, ISPR2021, 2022, : 521 - 530