Measuring Computed Tomography Scanner Variability of Radiomics Features

被引:528
|
作者
Mackin, Dennis [1 ]
Fave, Xenia [1 ,2 ]
Zhang, Lifei [1 ]
Fried, David [1 ,2 ]
Yang, Jinzhong [1 ]
Taylor, Brian [3 ,4 ]
Rodriguez-Rivera, Edgardo [5 ]
Dodge, Cristina [6 ]
Jones, Aaron Kyle [7 ]
Court, Laurence [1 ,7 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Hlth Sci Ctr Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
[3] Michael E DeBakey VA Med Ctr, Res Serv Line & Diagnost & Therapeut Care Line, Houston, TX USA
[4] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[5] Houston Methodist Hosp, Radiat Oncol Dept, Houston, TX USA
[6] Texas Childrens Hosp, Dept Diagnost Imaging, Houston, TX 77030 USA
[7] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
radiomics; image texture; image features; CT; computed tomography; phantom; TEXTURAL FEATURES; CT; IMAGES; REPRODUCIBILITY; CANCER;
D O I
10.1097/RLI.0000000000000180
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The purpose of this study was to determine the significance of interscanner variability in CT image radiomics studies. Materials and Methods We compared the radiomics features calculated for non-small cell lung cancer (NSCLC) tumors from 20 patients with those calculated for 17 scans of a specially designed radiomics phantom. The phantom comprised 10 cartridges, each filled with different materials to produce a wide range of radiomics feature values. The scans were acquired using General Electric, Philips, Siemens, and Toshiba scanners from 4 medical centers using their routine thoracic imaging protocol. The radiomics feature studied included the mean and standard deviations of the CT numbers as well as textures derived from the neighborhood gray-tone difference matrix. To quantify the significance of the interscanner variability, we introduced the metric feature noise. To look for patterns in the scans, we performed hierarchical clustering for each cartridge. Results The mean CT numbers for the 17 CT scans of the phantom cartridges spanned from -864 to 652 Hounsfield units compared with a span of -186 to 35 Hounsfield units for the CT scans of the NSCLC tumors, showing that the phantom's dynamic range includes that of the tumors. The interscanner variability of the feature values depended on both the cartridge material and the feature, and the variability was large relative to the interpatient variability in the NSCLC tumors for some features. The feature interscanner noise was greatest for busyness and least for texture strength. Hierarchical clustering produced different clusters of the phantom scans for each cartridge, although there was some consistent clustering by scanner manufacturer. Conclusions The variability in the values of radiomics features calculated on CT images from different CT scanners can be comparable to the variability in these features found in CT images of NSCLC tumors. These interscanner differences should be considered, and their effects should be minimized in future radiomics studies.
引用
下载
收藏
页码:757 / 765
页数:9
相关论文
共 50 条
  • [21] Prognostic value of computed tomography radiomics features in patients with gastric cancer following curative resection
    Wuchao Li
    Liwen Zhang
    Chong Tian
    Hui Song
    Mengjie Fang
    Chaoen Hu
    Yali Zang
    Ying Cao
    Shiyuan Dai
    Fang Wang
    Di Dong
    Rongpin Wang
    Jie Tian
    European Radiology, 2019, 29 : 3079 - 3089
  • [22] Prognostic value of computed tomography radiomics features in patients with gastric cancer following curative resection
    Li, Wuchao
    Zhang, Liwen
    Tian, Chong
    Song, Hui
    Fang, Mengjie
    Hu, Chaoen
    Zang, Yali
    Cao, Ying
    Dai, Shiyuan
    Wang, Fang
    Dong, Di
    Wang, Rongpin
    Tian, Jie
    EUROPEAN RADIOLOGY, 2019, 29 (06) : 3079 - 3089
  • [23] Impact of Reconstruction Field of View On Radiomics Features in Computed Tomography (CT) Using a Texture Phantom
    ul Hassan, M. Shafiq
    Zhang, G.
    Latifi, K.
    Oliver, J.
    Hunt, D.
    Guzman, R.
    Balagurunathan, Y.
    Mackin, D.
    Court, L.
    Gillies, R.
    Moros, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3705 - 3705
  • [24] Interobserver variability in measuring the dimensions of the abdominal aorta: Comparison of ultrasound and computed tomography
    Jaakkola, P
    Hippelainen, M
    Farin, P
    Rytkonen, H
    Kainulainen, S
    Partanen, K
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (02) : 230 - 237
  • [25] COMMISSIONING OF COMPUTED-TOMOGRAPHY SCANNER - OVERVIEW
    KIRKLAND, LR
    MORGAN, TJ
    OPTICAL ENGINEERING, 1977, 16 (01) : 32 - 36
  • [26] INTERPOLATION METHOD IN SIMPLE COMPUTED TOMOGRAPHY SCANNER
    Wiguna, Gede A.
    Suparta, Gede B.
    INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS 2014, 2015, 9302
  • [27] PROTOCOL FOR A COMPUTED TOMOGRAPHY SCANNER PERFORMANCE REPOSITORY
    COHEN, G
    PAYNE, JT
    BASSANO, DA
    CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1978, 2 (02): : 159 - 169
  • [28] MICROPROCESSOR CONTROL OF A COMPUTED-TOMOGRAPHY SCANNER
    HANGARTNER, TN
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 386 - 387
  • [29] Systematic analysis of bias and variability of morphologic features for lung lesions in computed tomography
    Hoye, Jocelyn
    Solomon, Justin
    Sauer, Thomas J.
    Robins, Marthony
    Samei, Ehsan
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (01)
  • [30] Precision of quantitative computed tomography texture analysis using image filtering A phantom study for scanner variability
    Yasaka, Koichiro
    Akai, Hiroyuki
    Mackin, Dennis
    Court, Laurence
    Moros, Eduardo
    Ohtomo, Kuni
    Kiryu, Shigeru
    MEDICINE, 2017, 96 (21)