AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance tests

被引:77
|
作者
Smith, Koren [1 ]
Balter, Peter [2 ]
Duhon, John [3 ]
White, Gerald A., Jr. [4 ]
Vassy, David L., Jr. [5 ]
Miller, Robin A. [6 ]
Serago, Christopher F. [7 ]
Fairobent, Lynne A. [8 ]
机构
[1] Mary Bird Perkins Canc Ctr, Baton Rouge, LA 70809 USA
[2] MD Anderson Canc Ctr, Houston, TX USA
[3] E OncoLog, Lafayette, LA USA
[4] Colorado Associates Med Phys, Colorado Springs, CO USA
[5] Spartanburg Reg Healthcare Syst, Spartanburg, SC USA
[6] Northwest Med Phys Ctr, Lynnwood, WA USA
[7] Mayo Clin, Jacksonville, FL 32224 USA
[8] AAPM Headquarters Staff, Alexandria, VA USA
来源
关键词
quality assurance; RADIATION-THERAPY; QUALITY-ASSURANCE; CLINICAL IMPLEMENTATION; IMRT;
D O I
10.1002/acm2.12080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this guideline is to provide a list of critical performance tests in order to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. Methods: A risk assessment was performed on tests from current task group reports on linac QA to highlight those tests that are most effective at maintaining safety and quality for the patient. Recommendations are made on the acquisition of reference or baseline data, the establishment of machine isocenter on a routine basis, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance. Results: The recommended tests proposed in this guideline were chosen based on the results from the risk analysis and the consensus of the guideline's committee. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. Conclusion: This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics.
引用
收藏
页码:23 / 39
页数:17
相关论文
共 39 条
  • [31] PRELIMINARY REPORT ON THE CLINICAL USE OF THE MEDICAL RESEARCH COUNCIL 8 MEV LINEAR ACCELERATOR
    MORRISON, R
    NEWBERY, GR
    DEELEY, TJ
    BRITISH JOURNAL OF RADIOLOGY, 1956, 29 (340): : 177 - 186
  • [32] Medical physics practice guideline 4.b: Development, implementation, use and maintenance of safety checklists
    Conroy, Leigh
    Faught, Jacqueline T.
    Bowers, Erika
    Ecclestone, Gillian
    de los Santos, Luis Fong E.
    Hsu, Annie
    Johnson, Jennifer Lynn
    Kim, Grace Gwe-Ya
    Schechter, Naomi
    Schubert, Leah K.
    Sterling, David A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (03):
  • [33] Medical Physics Practice Guideline (MPPG) 11.a: Plan and chart review in external beam radiotherapy and brachytherapy
    Xia, Ping
    Sintay, Benjamin J.
    Colussi, Valdir C.
    Chuang, Cynthia
    Lo, Yeh-Chi
    Schofield, Deborah
    Wells, Michelle
    Zhou, Sumin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 4 - 19
  • [35] Comparison of Rapid Arc and Intensity Modulated Radiotherapy in a True Beam Linear Accelerator for 6 MV: Application of AAPM TG-119 tests in treatment planning and quality assurance
    Roy, Soumya
    Sarkar, Biplab
    Pradhan, Anirudh
    PRECISION RADIATION ONCOLOGY, 2023, 7 (04): : 256 - 267
  • [36] Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator
    Saw, Cheng B.
    Yang, Yong
    Li, Fang
    Yue, Ning J.
    Ding, ChuXiong
    Komanduri, Krishna
    Huq, Saiful
    Heron, Dwight E.
    MEDICAL DOSIMETRY, 2007, 32 (02) : 80 - 85
  • [37] SOME ADVANCED DESIGN AND PERFORMANCE IN THE MEDICAL ELECTRON LINEAR-ACCELERATOR - NELAC-1018DP
    KAZUSA, C
    ABE, S
    YONEDA, M
    YAMAMOTO, T
    NEC RESEARCH & DEVELOPMENT, 1989, (93): : 80 - 88
  • [38] The General Medical Council's Performance Procedures: the development and implementation of tests of competence with examples from general practice
    Southgate, L
    Campbell, M
    Cox, Y
    Foulkes, O
    Jolly, B
    McCrorie, P
    Tombleson, P
    MEDICAL EDUCATION, 2001, 35 : 20 - 28
  • [39] Assessment in general practice: the predictive value of written-knowledge tests and a multiple-station examination for actual medical performance in daily practice
    Ram, P
    van der Vleuten, C
    Rethans, JJ
    Schouten, B
    Hobma, S
    Grol, R
    MEDICAL EDUCATION, 1999, 33 (03) : 197 - 203