AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance tests

被引:77
|
作者
Smith, Koren [1 ]
Balter, Peter [2 ]
Duhon, John [3 ]
White, Gerald A., Jr. [4 ]
Vassy, David L., Jr. [5 ]
Miller, Robin A. [6 ]
Serago, Christopher F. [7 ]
Fairobent, Lynne A. [8 ]
机构
[1] Mary Bird Perkins Canc Ctr, Baton Rouge, LA 70809 USA
[2] MD Anderson Canc Ctr, Houston, TX USA
[3] E OncoLog, Lafayette, LA USA
[4] Colorado Associates Med Phys, Colorado Springs, CO USA
[5] Spartanburg Reg Healthcare Syst, Spartanburg, SC USA
[6] Northwest Med Phys Ctr, Lynnwood, WA USA
[7] Mayo Clin, Jacksonville, FL 32224 USA
[8] AAPM Headquarters Staff, Alexandria, VA USA
来源
关键词
quality assurance; RADIATION-THERAPY; QUALITY-ASSURANCE; CLINICAL IMPLEMENTATION; IMRT;
D O I
10.1002/acm2.12080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this guideline is to provide a list of critical performance tests in order to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. Methods: A risk assessment was performed on tests from current task group reports on linac QA to highlight those tests that are most effective at maintaining safety and quality for the patient. Recommendations are made on the acquisition of reference or baseline data, the establishment of machine isocenter on a routine basis, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance. Results: The recommended tests proposed in this guideline were chosen based on the results from the risk analysis and the consensus of the guideline's committee. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. Conclusion: This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics.
引用
收藏
页码:23 / 39
页数:17
相关论文
共 39 条
  • [21] THE PERFORMANCE OF THE MEDICAL RESEARCH COUNCIL 8-MEV LINEAR ACCELERATOR
    NEWBERY, GR
    BEWLEY, DK
    BRITISH JOURNAL OF RADIOLOGY, 1955, 28 (329): : 241 - 251
  • [22] AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations - Megavoltage Photon and Electron Beams
    Smilowitz, Jennifer B.
    Das, Indra J.
    Feygelman, Vladimir
    Fraass, Benedick A.
    Kry, Stephen F.
    Marshall, Ingrid R.
    Mihailidis, Dimitris N.
    Ouhib, Zoubir
    Ritter, Timothy
    Snyder, Michael G.
    Fairobent, Lynne
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (05): : 14 - 34
  • [23] AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations - Megavoltage Photon and Electron Beams
    Smilowitz, Jennifer B.
    Das, Indra J.
    Feygelman, Vladimir
    Fraass, Benedick A.
    Geurts, Mark
    Kry, Stephen F.
    Marshall, Ingrid R.
    Mihailidis, Dimitris N.
    Ouhib, Zoubir
    Ritter, Timothy
    Snyder, Michael G.
    Fairobent, Lynne
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 457 - 457
  • [24] A brief history of the AAPM: Celebrating 60 years of contributions to medical physics practice and science
    Orton, Colin G.
    Giger, Maryellen L.
    MEDICAL PHYSICS, 2018, 45 (02) : 497 - 501
  • [25] AAPM Medical Physics Practice Guideline 2.a: Commissioning and quality assurance of X-ray-based image-guided radiotherapy systems
    Fontenot, Jonas D.
    Alkhatib, Hassaan
    Garrett, Jeffrey A.
    Jensen, Andrew R.
    McCullough, Steven P.
    Olch, Arthur J.
    Parker, Brent C.
    Yang, Ching-Chong Jack
    Fairobent, Lynne A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 3 - 13
  • [26] AAPM MEDICAL PHYSICS PRACTICE GUIDELINE 5.b: Commissioning and QA of treatment planning dose calculations-Megavoltage photon and electron beams
    Geurts, Mark W.
    Jacqmin, Dustin J.
    Jones, Lindsay E.
    Kry, Stephen F.
    Mihailidis, Dimitris N.
    Ohrt, Jared D.
    Ritter, Timothy
    Smilowitz, Jennifer B.
    Wingreen, Nicholai E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (09):
  • [27] AAPM MEDICAL PHYSICS PRACTICE GUIDELINE 2.b.: Commissioning and quality assurance of X-ray-based image-guided radiotherapy systems
    McCullough, Steven P.
    Alkhatib, Hassaan
    Antes, Kyle J.
    Castillo, Sarah
    Fontenot, Jonas D.
    Jensen, Andrew R.
    Matney, Jason
    Olch, Arthur J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 73 - 81
  • [28] OPERATIONAL RADIATION SAFETY FOR AN 8 MV MEDICAL LINEAR ACCELERATOR
    BUSHONG, SC
    HEALTH PHYSICS, 1970, 19 (01): : 81 - +
  • [29] THYRATRON PERFORMANCE - DEPENDENCE ON MOUNTING IN A MEDICAL LINEAR-ACCELERATOR
    BALAKRISHNAN, IS
    JAYARAMAN, R
    BHASKAR, BK
    LAKSHMANAN, AV
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (815): : 1242 - 1243
  • [30] Medical Physics Practice Guideline 4.a: Development, implementation, use and maintenance of safety checklists
    de los Santos, Luis E. Fong
    Evans, Suzanne
    Ford, Eric C.
    Gaiser, James E.
    Hayden, Sandra E.
    Huffman, Kristina E.
    Johnson, Jennifer L.
    Mechalakos, James G.
    Stern, Robin L.
    Terezakis, Stephanie
    Thomadsen, Bruce R.
    Pronovost, Peter J.
    Fairobent, Lynne A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 37 - 59