AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance tests

被引:77
|
作者
Smith, Koren [1 ]
Balter, Peter [2 ]
Duhon, John [3 ]
White, Gerald A., Jr. [4 ]
Vassy, David L., Jr. [5 ]
Miller, Robin A. [6 ]
Serago, Christopher F. [7 ]
Fairobent, Lynne A. [8 ]
机构
[1] Mary Bird Perkins Canc Ctr, Baton Rouge, LA 70809 USA
[2] MD Anderson Canc Ctr, Houston, TX USA
[3] E OncoLog, Lafayette, LA USA
[4] Colorado Associates Med Phys, Colorado Springs, CO USA
[5] Spartanburg Reg Healthcare Syst, Spartanburg, SC USA
[6] Northwest Med Phys Ctr, Lynnwood, WA USA
[7] Mayo Clin, Jacksonville, FL 32224 USA
[8] AAPM Headquarters Staff, Alexandria, VA USA
来源
关键词
quality assurance; RADIATION-THERAPY; QUALITY-ASSURANCE; CLINICAL IMPLEMENTATION; IMRT;
D O I
10.1002/acm2.12080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this guideline is to provide a list of critical performance tests in order to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. Methods: A risk assessment was performed on tests from current task group reports on linac QA to highlight those tests that are most effective at maintaining safety and quality for the patient. Recommendations are made on the acquisition of reference or baseline data, the establishment of machine isocenter on a routine basis, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance. Results: The recommended tests proposed in this guideline were chosen based on the results from the risk analysis and the consensus of the guideline's committee. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. Conclusion: This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics.
引用
收藏
页码:23 / 39
页数:17
相关论文
共 39 条
  • [1] AAPM Medical Physics Practice Guideline 8.b: Linear accelerator performance tests
    Krauss, Robert F.
    Balik, Salim
    Cirino, Eileen T.
    Hadley, Austin
    Hariharan, Navneeth
    Holmes, Shannon M.
    Kielar, Kayla
    Lavvafi, Hossein
    Mccullough, Kiernan
    Palefsky, Steven
    Sawyer, J. Phillip
    Smith, Koren
    Tracy, Jason
    Winter, Jeff D.
    Wingreen, Nicholai E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (11):
  • [2] AAPM PRACTICE GUIDELINES FOR PERFORMANCE TESTS FOR LINEAR ACCELERATOR
    Kumar, Pratik
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (04) : 277 - 277
  • [3] AAPM medical physics practice guideline 10.a.: Scope of practice for clinical medical physics
    Clements, Jessica B.
    Baird, Christopher T.
    de Boer, Steven F.
    Fairobent, Lynne A.
    Fisher, Tyler
    Goodwin, James H.
    Gress, Dustin A.
    Johnson, Jennifer Lynn
    Kolsky, Kathryn L.
    Mageras, Gig S.
    Marsh, Rebecca M.
    Martin, Melissa C.
    Parker, Brent
    Pavord, Daniel C.
    Schell, Michael C.
    Seibert, J. Anthony
    Stevens, Donna M.
    Tarver, Russell B.
    Waite-Jones, Christopher G.
    Wingreen, Nicholai
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 11 - 25
  • [4] AAPM Medical physics practice guideline 15.A: Peer review in clinical physics
    Halvorsen, Per H.
    Baydush, Alan H.
    Buckey, Courtney R.
    Hariharan, Navneeth
    Keenan, Mary A.
    Limmer, Jeffrey P.
    Lofton, Kate E.
    Miller, Robin A.
    Moirano, Jeffrey M.
    Och, Joseph
    Pfeiffer, Douglas E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (10):
  • [5] AAPM Medical Physics Practice Guideline 1.a: CT Protocol Management and Review Practice Guideline
    Cody, Dianna D.
    Fisher, Tyler S.
    Gress, Dustin A.
    Layman, Rick Robert, Jr.
    McNitt-Gray, Michael F.
    Pizzutiello, Robert J., Jr.
    Fairobent, Lynne A.
    Prisciandaro, Joann I.
    Chan, Maria F.
    Clements, Jessica B.
    Cody, Dianna D.
    Das, Indra J.
    Detorie, Nicholas A.
    Feygelman, Vladimir
    Fontenot, Jonas D.
    de los Santos, Luis E. Fong
    Gierga, David P.
    Huffman, Kristina E.
    Jordan, David W.
    Marshall, Ingrid R.
    Mutaf, Yildirim D.
    Olch, Arthur J.
    Pizzutiello, Robert J., Jr.
    Sahoo, Narayan
    Seibert, J. Anthony
    Shepard, S. Jeff
    Smilowitz, Jennifer B.
    VanDamme, James J.
    White, Gerald A., Jr.
    Yue, Ning J.
    Fairobent, Lynne A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (05): : 3 - 12
  • [6] AAPM medical physics practice guideline 7.a.: Supervision of medical physicist assistants
    Seibert, J. Anthony
    Blatnica, Anthony P.
    Clements, Jessica B.
    Halvorsen, Per H.
    Herman, Michael G.
    Johnson, Jennifer L.
    Schueler, Beth A.
    Martin, Melissa C.
    Palta, Jatinder R.
    Pfeiffer, Douglas E.
    Pizzutiello, Robert J.
    Prisciandaro, Joann, I
    Sherouse, George W.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 11 - 15
  • [7] AAPM Medical Physics Practice Guideline 12.a: Fluoroscopy dose management
    Fisher, Ryan F.
    Applegate, Kimberly E.
    Berkowitz, Lindsey K.
    Christianson, Olav
    Dave, Jaydev K.
    DeWeese, Lindsay
    Harris, Nichole
    Jafari, Mary Ellen
    Jones, A. Kyle
    Kobistek, Robert J.
    Loughran, Brendan
    Marous, Loren
    Miller, Donald L.
    Schueler, Beth
    Schwarz, Bryan C.
    Springer, Adam
    Wunderle, Kevin A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [8] AAPM medical physics practice guideline 13.a: HDR brachytherapy, part A
    Richardson, Susan L.
    Buzurovic, Ivan M.
    Cohen, Gil'ad N.
    Culberson, Wesley S.
    Dempsey, Claire
    Libby, Bruce
    Melhus, Christopher S.
    Miller, Robin A.
    Scanderbeg, Daniel J.
    Simiele, Samantha J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (03):
  • [9] AAPM Medical Physics Practice Guideline 1.b: CT protocol management and review practice guideline
    Cody, Dianna D.
    Dillon, Chad M.
    Fisher, Tyler S.
    Liu, Xinming
    McNitt-Gray, Michael F.
    Patel, Vikas
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 4 - 10
  • [10] AAPM medical physics practice guideline 6.a.: Performance characteristics of radiation dose index monitoring systems
    Gress, Dustin A.
    Dickinson, Renee L.
    Erwin, William D.
    Jordan, David W.
    Kobistek, Robert J.
    Stevens, Donna M.
    Supanich, Mark P.
    Wang, Jia
    Fairobent, Lynne A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 12 - 22