EVALUATION OF 4.0 MM CONICAL COLLIMATOR OUTPUT FACTOR FOR STEREOTACTIC RADIOSURGERY BEAMS

被引:0
|
作者
Zucca Aparicio, D. [1 ]
Garcia Ruiz-Zorrilla, J. [1 ]
Fernandez-Leton, P. [1 ]
Perez Moreno, J. M. [1 ]
Minambres, A. [1 ]
机构
[1] Hosp Univ Madrid Sanchinarro, Grp Hosp Madrid, Serv Radiofis & Protecc Radiol, Madrid, Spain
关键词
D O I
10.1016/S0167-8140(11)71255-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1133
引用
收藏
页码:S422 / S422
页数:1
相关论文
共 18 条
  • [1] Prediction of conical collimator collision for stereotactic radiosurgery
    Park, Jeonghoon
    McDermott, Ryan
    Kim, Sangroh
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 39 - 46
  • [2] Determination of output factors for stereotactic radiosurgery beams
    Fan, J.
    Paskalev, K.
    Wang, L.
    Jin, L.
    Li, J.
    Eldeeb, A.
    Ma, C.
    MEDICAL PHYSICS, 2009, 36 (11) : 5292 - 5300
  • [3] Determination of output factors for stereotactic radiosurgery beams by monte carlo and measurements
    Fan, J.
    Paskalev, K.
    Li, J.
    Wang, L.
    Chen, L.
    Price, R.
    Jin, L.
    ElDib, A.
    Ma, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2522 - 2522
  • [4] Modelling and commissioning validation of eclipse conical cone collimator for stereotactic radiosurgery using Monte Carlo simulation
    Shende, Ravindra
    Dhoble, S. J.
    Saroj, Dinesh
    Gupta, Gourav
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [5] Impact of Flattening Filter On Output Correction Factor of MicroDiamond Detector in Small-Field Stereotactic Radiosurgery Beams
    Arai, Y.
    Sato, Y.
    Takizawa, T.
    Fujii, K.
    Yasui, K.
    Sakai, K.
    Sato, M.
    Nakajima, Y.
    Fujita, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E948 - E948
  • [7] Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter)
    Paskalev, KA
    Seuntjens, JP
    Patrocinio, HJ
    Podgorsak, EB
    MEDICAL PHYSICS, 2003, 30 (02) : 111 - 118
  • [8] Monte Carlo-calculated dose distributions for dynamic stereotactic radiosurgery with 1.5 and 3 mm photon beams
    Paskalev, K
    Seuntjens, J
    Patrocinio, H
    Podgorsak, E
    MEDICAL PHYSICS, 2002, 29 (06) : 1250 - 1250
  • [9] Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams
    Bednarz, G
    Huq, MS
    Rosenow, UF
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (20): : 3643 - 3649
  • [10] A novel extrapolation method using OSL detectors for very small field output factor measurement for stereotactic radiosurgery
    Te-An Polly Huang
    Johnny E. Morales
    Ethan Butson
    Annie Johnson
    Martin Butson
    Robin Hill
    Physical and Engineering Sciences in Medicine, 2020, 43 : 593 - 599