A novel extrapolation method using OSL detectors for very small field output factor measurement for stereotactic radiosurgery

被引:0
|
作者
Te-An Polly Huang
Johnny E. Morales
Ethan Butson
Annie Johnson
Martin Butson
Robin Hill
机构
[1] University of Sydney,Institute of Medical Physics, School of Physics
[2] Chris O’Brien Lifehouse,Department of Radiation Oncology
[3] Queensland University of Technology,School of Chemistry, Physics and Mechanical Engineering
关键词
Small X-ray field dosimetry; OSLD; Extrapolation technique;
D O I
暂无
中图分类号
学科分类号
摘要
Appropriate methods for the determination of very small X-ray beam output factors are essential to ensure correct clinical outcomes for stereotactic radiosurgery. To date, substantial work has been performed in identifying and quantifying suitable dosimeters for relative output factor (ROF) measurements including recent IAEA published recommendations. In this work, we provide a novel method using optically stimulated luminescent dosimeters (OSLDs) with different effective sizes of the readout area to determine ROFs. This involves applying an extrapolation technique to assess ROFs for 6MV SRS X-ray beams with field diameters ranging from 4 to 30 mm as defined by the Brainlab SRS cones. By combining the use of multiple sized OSLDs and water droplets to remove air gaps located around the OSLD detectors, both volume averaging and density variation effects were minimised to estimate ROFs for an extrapolated zero volume detector. The measured results showed that for a 4 mm diameter cone, the ROF was 0.660 ± 0.032 (2SD) as compared to 0.661 ± 0.01 and 0.651 ± 0.018 for the PTW 600019 microDiamond detector and Gafchromic EBT3 film respectively. Whilst the uncertainties were larger than conventional detectors, the technique shows promise and improvements in accuracy may be obtained by higher quality manufacturing techniques. Based on these results, using OSLDs with different effective sizes of readout area and an extrapolation technique shows promise for use as an independent verification tool for very small X-ray field ROFs in the clinical department.
引用
收藏
页码:593 / 599
页数:6
相关论文
共 50 条
  • [1] A novel extrapolation method using OSL detectors for very small field output factor measurement for stereotactic radiosurgery
    Huang, Te-An Polly
    Morales, Johnny E.
    Butson, Ethan
    Johnson, Annie
    Butson, Martin
    Hill, Robin
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 593 - 599
  • [2] Small field output factor measurement using various active detectors and OSLD
    Shamurailatpam, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S11 - S12
  • [3] Measurement of Output and Percent Depth Dose (PDD) for Small Stereotactic Radiosurgery (SRS) Cones Using Semiconductor and Microdiamond Detectors
    Lief, E.
    Dawson, G.
    Restrepo, J.
    Beyer, G.
    Jeffe, P.
    Cheuk, A.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E431 - E431
  • [4] Evaluation of detectors response for small field output factor measurement using Gafchromic film
    Rucka, G.
    Patrice, B.
    Asquier, N.
    Mouttet, J. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S686 - S687
  • [5] Glass rod detectors for small field, stereotactic radiosurgery dosimetric audit
    Perks, J
    Gao, M
    Smith, V
    Skubic, S
    Goetsch, S
    [J]. MEDICAL PHYSICS, 2005, 32 (03) : 726 - 732
  • [6] Characterization of small-field stereotactic radiosurgery beams with modern detectors
    Tyler, Madelaine
    Liu, Paul Z. Y.
    Chan, Kin Wa
    Ralston, Anna
    McKenzie, David R.
    Downes, Simon
    Suchowerska, Natalka
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7595 - 7608
  • [7] Measurement of Small Field Output Factors Using Plastic Scintillation Detectors
    Klein, D.
    Tailor, R.
    Archambault, L.
    Wang, L.
    Therriault-Proulx, F.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [8] Verification of relative output factor measurement using Gafchromic films for small-field radiosurgery photon beams
    Abdullah, R.
    Sapeei, M. S.
    Shukor, N. S. A.
    Yusof, M. F. M.
    Mohamed, M.
    Idris, N. R. N.
    Yusoff, A. L.
    Zakaria, A.
    Aziz, M. Z. A.
    [J]. INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2017 (INUSTEC2017), 2018, 298
  • [9] Impact of Flattening Filter On Output Correction Factor of MicroDiamond Detector in Small-Field Stereotactic Radiosurgery Beams
    Arai, Y.
    Sato, Y.
    Takizawa, T.
    Fujii, K.
    Yasui, K.
    Sakai, K.
    Sato, M.
    Nakajima, Y.
    Fujita, Y.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E948 - E948
  • [10] An efficient method for small field treatment dose calculation for stereotactic radiosurgery using a LINAC
    Lam, CF
    Zhu, JG
    [J]. MEDICAL PHYSICS, 1998, 25 (05) : 676 - 682