Structure and function evaluation (SAFE): I. Criteria for glaucomatous visual field loss using standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP)

被引:98
|
作者
Johnson, CA
Sample, PA
Cioffi, GA
Liebmann, JR
Weinreb, RN
机构
[1] Devers Eye Inst, Discoveries Slight Res Labs, Portland, OR 97210 USA
[2] Univ Calif San Diego, Glaucoma Ctr, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Visual Funct Lab, San Diego, CA 92103 USA
[4] New York Eye & Ear Infirm, New York, NY 10003 USA
关键词
D O I
10.1016/S0002-9394(02)01577-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To develop criteria for detecting glaucomatous visual field loss for standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP). DESIGN: Longitudinal observational study. METHODS: Three populations were evaluated: (1) 348 normal subjects (348 eyes) were tested to develop nor, mative databases and statistical analysis packages for SAP and SWAP. (2) An independent group of 47 normal subjects (94 eyes) with 4 years of longitudinal follow-up was evaluated to determine specificity of different criteria. (3) A group of 298 patients (479 eyes) with elevated intraocular pressure and normal baseline SAP visual fields were evaluated to determine the sensitivity of different criteria for detecting early glaucomatous visual field loss. RESULTS: Six criteria demonstrated high specificity for correctly identifying eyes with normal visual fields (98%-100%) for both SAP and SWAP: (1) a pattern standard deviation (PSD) worse than the normal 1% level, (2) a glaucoma hemifield test (GHT) "outside normal limits," (3) one hemifield cluster worse than the normal 1% level, (4) two hemifield clusters worse than the normal 5% level, (5) four abnormal (P < .05) locations, (6) five abnormal locations (P < .05) on the pattern deviation probability plot. For all criteria, confirmation on a second visual field was required for high specificity. The GHT "outside normal limits," two hemi. field clusters worse than the normal 5% level and four abnormal (P < .05) test locations on the pattern deviation probability plot provided the highest percentages of conversion from a normal to a glaucomatous visual field. CONCLUSIONS: Criteria based on the GHT, GHT hemifield clusters, and the pattern deviation probability plot provide high sensitivity and specificity for detecting early glaucomatous visual field changes. (C) 2002 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 50 条
  • [41] CONFRONTATION VISUAL-FIELD LOSS AS A FUNCTION OF DECIBEL SENSITIVITY LOSS ON AUTOMATED STATIC PERIMETRY - IMPLICATIONS ON THE ACCURACY OF CONFRONTATION VISUAL-FIELD TESTING
    SHAHINFAR, S
    JOHNSON, LN
    MADSEN, RW
    OPHTHALMOLOGY, 1995, 102 (06) : 872 - 877
  • [42] Structure-function Relationships Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry
    Leite, Mauro T.
    Zangwill, Linda M.
    Weinreb, Robert N.
    Rao, Harsha L.
    Alencar, Luciana M.
    Medeiros, Felipe A.
    JOURNAL OF GLAUCOMA, 2012, 21 (01) : 49 - 54
  • [43] CONFRONTATION VISUAL-FIELD LOSS AS A FUNCTION OF DECIBEL SENSITIVITY LOSS ON AUTOMATED STATIC PERIMETRY - IMPLICATIONS ON THE ACCURACY OF CONFRONTATION VISUAL-FIELD (CVF) TESTING
    SHAHINFAR, S
    JOHNSON, LN
    MADSEN, RW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S454 - S454
  • [44] Relationship between optical coherence tomography retinal nerve fiber thickness measurements and visual field abnormalities measured by standard automated perimetry in glaucomatous eyes
    Sekhon, N
    Venkataraman, A
    Budenz, DL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [45] The incidence of visual field defects at each of 52 locations in standard automated perimetry in glaucomatous eyes - Data from the diagnostic innovations in glaucoma study (DIGS)
    Hu, A
    Pascual, JP
    Weinreb, RN
    Sample, PA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [46] Structure-Function Relationships between Macular Retinal Thickness using HRT3 and Standard Automated Perimetry
    Farantzos, George
    Kourkoutas, Dimitrios
    Paraskevopoulos, Theodoros
    Karamaounas, Aristotelis
    Karamaounas, Nicolaos
    Triantafyllopoulos, Georges
    Lygeros, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [47] Structure-Function Relationship in Glaucoma Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry
    Leite, M. T.
    Zangwill, L. M.
    Weinreb, R. N.
    Sample, P. A.
    Rao, H. L.
    Alencar, L. M.
    Bow, C.
    Medeiros, F. A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [48] Correlation of Binocular Perimetry Screening Using imo: A Portable Head Mounted Perimeter With 10-2 Standard Automated Perimetry for Early Glaucoma With Central Visual Field Defects
    Nishijima, Euido
    Itoh, Yoshinori
    Noro, Takahiko
    Ogawa, Shumpei
    Okude, Sachiyo
    Nakano, Tadashi
    JOURNAL OF GLAUCOMA, 2025, 34 (02) : 89 - 94
  • [49] Topical dorzolamide increases pericentral visual function in age-related maculopathy: pilot study findings with short-wavelength automated perimetry
    Remky, A
    Weber, A
    Arend, O
    Sponsel, WE
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (02): : 154 - 160
  • [50] A COMPARISON OF EXPERIENCED CLINICAL OBSERVERS AND STATISTICAL TESTS IN DETECTION OF PROGRESSIVE VISUAL-FIELD LOSS IN GLAUCOMA USING AUTOMATED PERIMETRY
    WERNER, EB
    BISHOP, KI
    KOELLE, J
    DOUGLAS, GR
    LEBLANC, RP
    MILLS, RP
    SCHWARTZ, B
    WHALEN, WR
    WILENSKY, JT
    ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (05) : 619 - 623