Moving approximate entropy applied to surface electromyographic signals

被引:26
|
作者
Ahmad, Siti A. [1 ]
Chappell, Paul H. [1 ]
机构
[1] Univ Southampton, Sch Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
关键词
Surface EMG; Flexor and extensor muscles; Moving approximate entropy;
D O I
10.1016/j.bspc.2007.10.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this Study was to investigate the surface electromyographic signals using moving approximate entropy from 20 healthy participants' wrist muscles (flexor carpi ulnaris and flexor carpi radialis). The participants were required to voluntary performed wrist flexion/extension, co-contraction and isometric contraction. A moving data window of 200 values was applied to the data and a moving approximate entropy series was obtained from the analysis. The results demonstrate that there are distinct drops of the approximate entropy Values at the start and end of a contraction. and high (less regularity) approximate entropy in the middle. Mean values of approximate entropy of 0.54 and 0.55 were found for the start of a contraction compared to 0.79 and 0.77 during the middle. for the flexor and extensor, respectively. At the end, there are values of 0.46 and 0.5. respectively. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 50 条
  • [41] Assessing muscle fatigue in multiple sclerosis using the sample entropy of electromyographic signals: A proof of concept
    Gomez-Hernandez, Marina
    Olaya-Mira, Natali
    Viloria-Barragan, Carolina
    Henao-Perez, Julieta
    Rojas-Mora, Jessica Maria
    Diaz-Londono, Gloria
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2023, 13 (02): : 153 - 159
  • [42] STATISTIC MEASUREMENTS FOR ENTROPY CODING OF MOVING AREAS IN VIDEO TELEPHONE SIGNALS
    BOSTELMANN, G
    NACHRICHTENTECHNISCHE ZEITSCHRIFT, 1976, 29 (03): : 261 - 264
  • [43] EEG Signals Feature Extraction Based on DWT and EMD Combined with Approximate Entropy
    Ji, Na
    Ma, Liang
    Dong, Hui
    Zhang, Xuejun
    BRAIN SCIENCES, 2019, 9 (08)
  • [44] Estimation of Complexity of Sampled Biomedical Continuous Time Signals Using Approximate Entropy
    Mesin, Luca
    FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [45] Measurement of cardiac synchrony using Approximate Entropy applied to nuclear medicine scans
    Cullen, James
    Saleem, Azeem
    Swindell, Ric
    Burt, Paul
    Moore, Chris
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2010, 5 (01) : 32 - 36
  • [46] CYCLOSTATIONARY ANALYSIS OF ELECTROMYOGRAPHIC SIGNALS
    Roussel, J.
    Haritopoulos, M.
    Ravier, P.
    Buttelli, O.
    2013 PROCEEDINGS OF THE 21ST EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2013,
  • [47] Approximate relationship for temperature in the center of moving on the thin plate surface
    Sukhumskij Fiziko-Tekhnicheskij Inst, Sukhumi, Russia
    Fizika i Khimiya Obrabotki Materialov, 1998, (02): : 24 - 26
  • [48] Anomaly Detection of Electromyographic Signals
    Ijaz, Ahsan
    Choi, Jongeun
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (04) : 770 - 779
  • [49] Exoskeleton Recognition of Human Movement Intent Based on Surface Electromyographic Signals: Review
    Lu, Changjia
    Qi, Qingjie
    Liu, Yingjie
    Li, Dan
    Xian, Wenhao
    Wang, Yue
    Chen, Changbing
    Xu, Xin
    IEEE ACCESS, 2024, 12 : 53986 - 54004
  • [50] A blinking periorbital prosthesis using surface electromyographic signals of the orbicularis oculi muscle
    Akamatsu T.
    Kawashima N.
    Tsunekuni T.
    Imagawa K.
    Miyasaka M.
    European Journal of Plastic Surgery, 2015, 38 (5) : 371 - 376