Moving approximate entropy applied to surface electromyographic signals

被引:26
|
作者
Ahmad, Siti A. [1 ]
Chappell, Paul H. [1 ]
机构
[1] Univ Southampton, Sch Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
关键词
Surface EMG; Flexor and extensor muscles; Moving approximate entropy;
D O I
10.1016/j.bspc.2007.10.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this Study was to investigate the surface electromyographic signals using moving approximate entropy from 20 healthy participants' wrist muscles (flexor carpi ulnaris and flexor carpi radialis). The participants were required to voluntary performed wrist flexion/extension, co-contraction and isometric contraction. A moving data window of 200 values was applied to the data and a moving approximate entropy series was obtained from the analysis. The results demonstrate that there are distinct drops of the approximate entropy Values at the start and end of a contraction. and high (less regularity) approximate entropy in the middle. Mean values of approximate entropy of 0.54 and 0.55 were found for the start of a contraction compared to 0.79 and 0.77 during the middle. for the flexor and extensor, respectively. At the end, there are values of 0.46 and 0.5. respectively. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 50 条
  • [31] FILTERING OF ELECTROMYOGRAPHIC SIGNALS
    GOTTLIEB, GL
    AGARWAL, GC
    AMERICAN JOURNAL OF PHYSICAL MEDICINE, 1970, 49 (02): : 142 - &
  • [32] Approximate entropy and its preliminary applications in the analysis of mechanical vibration signals
    Xu, YG
    He, ZJ
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON VIBRATION ENGINEERING, 2002, : 683 - 687
  • [33] AMPLIFIER FOR ELECTROMYOGRAPHIC SIGNALS
    BALL, RL
    AMERICAN JOURNAL OF PHYSICAL MEDICINE, 1969, 48 (03): : 116 - &
  • [34] Multiscale Entropy Analysis of Surface Electromyographic Signals from the Urethral Sphincter as a Prognostic Indicator for Surgical Candidates with Primary Bladder Neck Obstruction
    Wu, Hsien-Tsai
    Jiang, Yuan-Hong
    Liu, An-Bang
    Liu, Chun-Wei
    Ou, Yu-Nian
    Kuo, Hann-Chorng
    Sun, Cheuk-Kwan
    ENTROPY, 2015, 17 (12) : 8089 - 8098
  • [35] Classification of Surface Electromyographic Signals using AM-FM Features
    Christodoulou, Christodoulos I.
    Kaplanis, Prodromos A.
    Murray, Victor
    Pattichis, Marios S.
    Pattichis, Constantinos S.
    2009 9TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, 2009, : 433 - +
  • [36] Robust Outlier Detection in High-Density Surface Electromyographic Signals
    Marateb, H. R.
    Rojas-Martinez, M.
    Mananas Villanueva, M. A.
    Merletti, R.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4850 - 4853
  • [37] Effects of minimum sampling rate and signal reconstruction on surface electromyographic signals
    Durkin, JL
    Callaghan, JP
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (05) : 474 - 481
  • [38] Variation of instantaneous spectral centroid across bands of surface electromyographic signals
    Krishnamani D.B.
    Karthick P.A.
    Swaminathan R.
    Biomedical Sciences Instrumentation, 2021, 57 (02) : 356 - 360
  • [39] Maximum likelihood algorithm to estimate conduction velocity in surface electromyographic signals
    Salomoni, S.
    Soares, F. A.
    Nascimento, F. A. O.
    Verieziano, W. H.
    da Rocha, A. F.
    IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 1049 - 1053
  • [40] Effects of electromagnetic pulses on approximate entropy of multichannel EEG in freely moving rats
    Li, J
    Wang, J
    Guo, GZ
    Guo, Y
    Jian, Z
    ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, CEEM'2003, PROCEEDINGS, 2003, : 134 - 137