Moving approximate entropy applied to surface electromyographic signals

被引:26
|
作者
Ahmad, Siti A. [1 ]
Chappell, Paul H. [1 ]
机构
[1] Univ Southampton, Sch Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
关键词
Surface EMG; Flexor and extensor muscles; Moving approximate entropy;
D O I
10.1016/j.bspc.2007.10.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this Study was to investigate the surface electromyographic signals using moving approximate entropy from 20 healthy participants' wrist muscles (flexor carpi ulnaris and flexor carpi radialis). The participants were required to voluntary performed wrist flexion/extension, co-contraction and isometric contraction. A moving data window of 200 values was applied to the data and a moving approximate entropy series was obtained from the analysis. The results demonstrate that there are distinct drops of the approximate entropy Values at the start and end of a contraction. and high (less regularity) approximate entropy in the middle. Mean values of approximate entropy of 0.54 and 0.55 were found for the start of a contraction compared to 0.79 and 0.77 during the middle. for the flexor and extensor, respectively. At the end, there are values of 0.46 and 0.5. respectively. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 50 条
  • [1] The approximate entropy of the electromyographic signals of tremor correlates with the osmotic fragility of human erythrocytes
    Paulo HG Mansur
    Lacordaire KP Cury
    José OB Leite
    Adriano A Pereira
    Nilson Penha-Silva
    Adriano O Andrade
    BioMedical Engineering OnLine, 9
  • [2] The approximate entropy of the electromyographic signals of tremor correlates with the osmotic fragility of human erythrocytes
    Mansur, Paulo H. G.
    Cury, Lacordaire K. P.
    Leite, Jose O. B.
    Pereira, Adriano A.
    Penha-Silva, Nilson
    Andrade, Adriano O.
    BIOMEDICAL ENGINEERING ONLINE, 2010, 9
  • [3] Surface EMG Classification Using Moving Approximate Entropy
    Ahmad, Siti A.
    Chappell, Paul H.
    ICIAS 2007: INTERNATIONAL CONFERENCE ON INTELLIGENT & ADVANCED SYSTEMS, VOLS 1-3, PROCEEDINGS, 2007, : 1163 - 1167
  • [5] Entropy based fatigue identification in spinal surface electromyographic signals using wavelets
    Panagiotacopulos, ND
    Lee, JS
    Friesen, K
    Wan, L
    ADVANCES IN INTELLIGENT SYSTEMS: CONCEPTS, TOOLS AND APPLICATIONS, 1999, 21 : 487 - 498
  • [6] Characterization of surface EMG signals using improved approximate entropy.
    Chen W.T.
    Wang Z.Z.
    Ren X.M.
    Journal of Zhejiang University SCIENCE B, 2006, 7 (10): : 844 - 848
  • [7] Radar jamming detection based on approximate entropy and moving-cut approximate entropy
    College of Electronic Science and Engineering, National University of Defense Technology, Changsha, China
    IET Conf Publ, 1600, 636 CP
  • [8] Moving deletion approximate entropy analysis of arc signals for high-power submerged arc welding
    Zhou, Yiqing
    Chang, Shiuan-Ho
    Wu, Shuguang
    Cai, Xiongyou
    Xu, Ribin
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 231 - 232
  • [9] Multiscale Entropy Analysis of Surface Electromyographic Signals as a Prognostic Indicator for Subtle Functional Impairment of Urethral Sphincter
    Wu, Hsien-Tsai
    Pan, Wen-Yao
    Liu, Chun-Wei
    Kuo, Hann-Chorng
    Jiang, Yuan-Hong
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 205 - 208
  • [10] Surface Electromyographic Signals Using Dry Electrodes
    Laferriere, Pascal
    Lemaire, Edward D.
    Chan, Adrian D. C.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (10) : 3259 - 3268