Performance of the rapid plasma reagin and the rapid syphilis screening tests in the diagnosis of syphilis in field conditions in rural Africa

被引:40
|
作者
West, B
Walraven, G
Morison, L
Brouwers, J
Bailey, R
机构
[1] MRC Labs, Reprod Hlth Programme, Banjul, Gambia
[2] Univ London London Sch Hyg & Trop Med, London WC1E 7HT, England
关键词
D O I
10.1136/sti.78.4.282
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objectives: To assess the rapid plasma reagin (RPR) test performance in the field and to;evaluate a new rapid syphilis test (RST) as a primary screen for syphilis. Methods: 1325 women of reproductive age from rural communities in the Gambia were tested for syphilis seropositivity using a RPR 18 mm circle card and a RST strip. Within 1 week a repeat RPR and a TPHA test were carried out using standard techniques in the laboratory. Results: Comparing field tests to a diagnosis of "active" syphilis defined as laboratory RPR and TPHA positive, the RPR test was 77.5% sensitive and 94.1% specific; the RST was 75.0% sensitive and 95.2% specific. The RST was easier to use and interpret than the RPR test especially where field conditions were difficult. In this setting with a low prevalence of syphilis in the community (3%), the chance of someone with a positive test being confirmed as having serologically active syphilis was less than 50% for both tests. Conclusions: The appropriateness of syphilis screening using RPR testing in antenatal clinics and health centres should be questioned if there is a low prevalence in the population, conditions for testing are poor, and resources limited. There is still an urgent need for an appropriate rapid syphilis test for field use.
引用
收藏
页码:282 / 285
页数:4
相关论文
共 50 条
  • [31] Clinical features and rapid plasma reagin antibody titers in spontaneous and experimental rabbit syphilis
    Saito, K
    Tagawa, M
    Mimura, M
    Hasegawa, A
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2005, 67 (07): : 739 - 741
  • [32] CAN RAPID SYPHILIS TESTS BE IMPLEMENTED AND IMPROVE SCREENING FOR MATERNAL SYPHILIS IN A THIRD LEVEL HOSPITAL?
    Roca, S. La Rosa
    Garcia, P.
    SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A211 - A211
  • [33] Predictive value of past and current screening tests for syphilis in blood donors: changing from a rapid plasma reagin test to an automated specific treponemal test for screening
    Aberle-Grasse, J
    Orton, SL
    Notari, E
    Layug, LP
    Cable, RG
    Badon, S
    Popovsky, MA
    Grindon, AJ
    Lenes, BA
    Williams, AE
    TRANSFUSION, 1999, 39 (02) : 206 - 211
  • [34] Evaluation of a rapid strip and a particle agglutination tests for syphilis diagnosis
    Juarez-Figueroa, Luis
    Uribe-Salas, Felipe
    Garcia-Cisneros, Santa
    Olamendi-Portugal, Maria
    Conde-Glez, Carlos J.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2007, 59 (02) : 123 - 126
  • [35] Evaluation of rapid diagnostic tests: syphilis
    Alan Herring
    Ron Ballard
    David Mabey
    Rosanna W. Peeling
    Nature Reviews Microbiology, 2006, 4 : S33 - S40
  • [36] Evaluation of rapid diagnostic tests: syphilis
    Herring, Alan
    Ballard, Ron
    Mabey, David
    Peeling, Rosanna W.
    NATURE REVIEWS MICROBIOLOGY, 2006, 4 (Suppl 12) : S33 - S40
  • [37] Practical Application of Quantitative HiSens Auto Rapid Plasma Reagin Latex Turbidimetric Immunoagglutination for Diagnosing Syphilis; Comparison Analysis between Rapid Plasma Reagin Latex Turbidimetric Immunoagglutination Test and Rapid Plasma Reagin Card Test
    Hwang, Hyun Yong
    Kim, Mi Hyang
    INFECTION AND CHEMOTHERAPY, 2009, 41 (03): : 154 - 159
  • [39] RAPID MACROSCOPIC SCREENING TEST FOR SYPHILIS
    LUCATORTO, FM
    TOTO, PD
    KATZ, BD
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1964, 69 (06): : 697 - &
  • [40] COMPARATIVE STUDIES OF RAPID PLASMA REAGIN CARD TEST FOR SYPHILIS + VDRL SLIDE TEST IN ETHIOPA
    BUCK, AA
    MAYER, H
    AMERICAN JOURNAL OF HYGIENE, 1964, 80 (01): : 85 - &