Performance of the rapid plasma reagin and the rapid syphilis screening tests in the diagnosis of syphilis in field conditions in rural Africa

被引:40
|
作者
West, B
Walraven, G
Morison, L
Brouwers, J
Bailey, R
机构
[1] MRC Labs, Reprod Hlth Programme, Banjul, Gambia
[2] Univ London London Sch Hyg & Trop Med, London WC1E 7HT, England
关键词
D O I
10.1136/sti.78.4.282
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objectives: To assess the rapid plasma reagin (RPR) test performance in the field and to;evaluate a new rapid syphilis test (RST) as a primary screen for syphilis. Methods: 1325 women of reproductive age from rural communities in the Gambia were tested for syphilis seropositivity using a RPR 18 mm circle card and a RST strip. Within 1 week a repeat RPR and a TPHA test were carried out using standard techniques in the laboratory. Results: Comparing field tests to a diagnosis of "active" syphilis defined as laboratory RPR and TPHA positive, the RPR test was 77.5% sensitive and 94.1% specific; the RST was 75.0% sensitive and 95.2% specific. The RST was easier to use and interpret than the RPR test especially where field conditions were difficult. In this setting with a low prevalence of syphilis in the community (3%), the chance of someone with a positive test being confirmed as having serologically active syphilis was less than 50% for both tests. Conclusions: The appropriateness of syphilis screening using RPR testing in antenatal clinics and health centres should be questioned if there is a low prevalence in the population, conditions for testing are poor, and resources limited. There is still an urgent need for an appropriate rapid syphilis test for field use.
引用
收藏
页码:282 / 285
页数:4
相关论文
共 50 条
  • [21] Rapid Plasma Reagin Titer Variation in the 2 Weeks After Syphilis Therapy
    Holman, Katherine M.
    Wolff, Mark
    Sena, Arlene C.
    Martin, David H.
    Behets, Frieda
    Van Damme, Kathleen
    Leone, Peter
    McNeil, Linda
    Gehrig, Meredyth L.
    Hook, Edward W., III
    SEXUALLY TRANSMITTED DISEASES, 2012, 39 (08) : 645 - 647
  • [22] Use of the Treponema pallidum specific Captia Syphilis IgG assay in conjunction with the rapid plasma reagin to test for syphilis
    Reisner, BS
    Mann, LM
    Tholcken, CA
    Waite, RT
    Woods, GL
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (05) : 1141 - 1143
  • [23] Evaluation of the fully automated AIX1000 rapid plasma reagin system compared to a manual plasma reagin testing method for the diagnosis of syphilis
    Pyden, Alexander
    Kang, Anthony D.
    Amato, Sheryl
    Dutta, Sanjucta
    Berg, Gretchen
    Riedel, Stefan
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2020, 97 (04)
  • [24] Challenges of Rapid Plasma Reagin Interpretation in Syphilis Screening in Uganda: Variability in Nontreponemal Results Between Different Laboratories
    Hamill, Matthew M.
    Mbazira, Kimeze J.
    Kiragga, Agnes N.
    Gaydos, Charlotte A.
    Jett-Goheen, Mary
    Parkes-Ratanshi, Rosalind
    Manabe, Yukari C.
    Nakku-Joloba, Edith
    Rompalo, Anne
    SEXUALLY TRANSMITTED DISEASES, 2018, 45 (12) : 829 - 833
  • [25] Comparative evaluation of enzyme-linked immunosorbent assay with rapid plasma reagin for screening of syphilis in blood donors
    Sachdev, Suchet
    Sharma, Arun Kumar
    Sethi, Sunil
    Garg, Sachin
    Lamba, Divjot Singh
    Sharma, Ratti Ram
    Marwaha, Neelam
    ASIAN JOURNAL OF TRANSFUSION SCIENCE, 2018, 12 (02): : 165 - 168
  • [26] Comparison of Manual and Fully Automated AIX1000 Rapid Plasma Reagin Assays for Laboratory Diagnosis of Syphilis
    Sanfilippo, Alan M.
    Freeman, Kristie
    Schmitz, John L.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (08)
  • [27] Syphilis Rapid Tests Used During a Localized Syphilis Outbreak in a Rural Public Health Setting
    Watkins, Margret
    Hudson, Alana
    Huff, Bianca
    SEXUALLY TRANSMITTED DISEASES, 2024, 51 (01) : S396 - S397
  • [28] Comparison of Syphilis Rapid Diagnostic Test to Rapid Plasma Reagin, Treponema pallidum Haemagglutination Assay and Fluorescent Treponemal Antibody Absorption for Syphilis and Yaws Diagnostics
    Giantini, Astuti
    Wulandari, Dewi
    Suparmin, Siskawati
    INDONESIAN BIOMEDICAL JOURNAL, 2020, 12 (02): : 136 - 142
  • [29] Secondary Syphilis: An Atypical Presentation Complicated by a False Negative Rapid Plasma Reagin Test
    Lombardo, Jamie
    Alhashim, Minhal
    CUTIS, 2018, 101 (05): : E11 - E13
  • [30] What Is the Role of Paired Rapid Plasma Reagin Testing (Simultaneous Testing of Acute and Convalescent Samples) in the Diagnosis of Repeat Syphilis and the Follow-up of Syphilis?
    Kenyon, Chris R.
    Osbak, Kara Krista
    Van Esbroek, Marjan
    Lynen, Lutgarde
    Crucitti, Tania
    SEXUALLY TRANSMITTED DISEASES, 2018, 45 (01) : 35 - 38