A comparison of gas velocity measurements in a full-scale enclosure fire

被引:29
|
作者
Bryant, Rodney A. [1 ]
机构
[1] Natl Inst Stand & Technol, Bldg & Fire Res Lab, Gaithersburg, MD 20899 USA
关键词
Flow measurement; Fire-induced flow; Particle image velocimetry; Bi-directional probe;
D O I
10.1016/j.firesaf.2009.03.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Gas velocity measurements were conducted in the doorway of an enclosure containing a natural gas fire. Two independent measurement techniques, Stereoscopic Particle Image Velocimetry (SPIV) and bidirectional impact-pressure probes, were utilized for comparison - the first such comparison for a fire-induced flow in a full-scale structural fire. Gas velocities inferred from the bi-directional probe measurements were consistently greater than SPIV measurements in a region of the flow between the floor and the flow interface. The comparison revealed that a measurement bias exists in the bidirectional probe technique. Estimates of the relative magnitude of the bias were inferred from the results. Published by Elsevier Ltd.
引用
收藏
页码:793 / 800
页数:8
相关论文
共 50 条
  • [21] Full-scale deformation measurements of a wind turbine rotor in comparison with aeroelastic simulations
    Lehnhoff, Stephanie
    Gonzalez, Alejandro Gomez
    Seume, Jorg R.
    [J]. WIND ENERGY SCIENCE, 2020, 5 (04) : 1411 - 1423
  • [22] Full-Scale Fire Test of an Intercity Train Car
    Duck Hee Lee
    Won Hee Park
    Jungho Hwang
    George Hadjisophocleous
    [J]. Fire Technology, 2016, 52 : 1559 - 1574
  • [23] Full-scale fire testing of battery electric vehicles
    Kang, Sungwook
    Kwon, Minjae
    Choi, Joung Yoon
    Choi, Sengkwan
    [J]. APPLIED ENERGY, 2023, 332
  • [24] MODEL FULL-SCALE PRESSURE MEASUREMENTS ON A GRANDSTAND
    APPERLEY, LW
    PITSIS, NG
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1986, 23 (1-3) : 99 - 111
  • [25] Full-scale damping measurements of structures in Australia
    Glanville, MJ
    Kwok, KCS
    Denoon, RO
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 59 (2-3) : 349 - 364
  • [26] Study of attached air curtain ventilation within a full-scale enclosure: comparison of four turbulence models
    Yin, Haiguo
    Li, Angui
    [J]. INDOOR AND BUILT ENVIRONMENT, 2016, 25 (06) : 962 - 975
  • [27] Full-scale measurements of the manoeuvring capabilities of a catamaran
    Soares, CG
    Sutulo, S
    Francisco, RA
    Santos, FM
    Moreira, L
    [J]. INTERNATIONAL CONFERENCE ON HYDRODYNAMICS OF HIGH SPEED CRAFT, 1999, : H1 - H12
  • [28] MEASUREMENTS OF WIND LOADS ON FULL-SCALE GLASSHOUSES
    WELLS, DA
    HOXEY, RP
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1980, 6 (1-2) : 139 - 167
  • [29] Full-scale measurements of stay cable vibration
    Main, JA
    Jones, NP
    [J]. WIND ENGINEERING INTO THE 21ST CENTURY, VOLS 1-3, 1999, : 963 - 970
  • [30] Full-scale measurements for wind effects on buildings
    Mehta, KC
    Smith, DA
    [J]. ENGINEERING, CONSTRUCTION AND OPERATIONS IN CHALLENGING ENVIRONMENTS: EARTH AND SPACE 2004, 2004, : 190 - 194