Study of attached air curtain ventilation within a full-scale enclosure: comparison of four turbulence models

被引:26
|
作者
Yin, Haiguo [1 ]
Li, Angui [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Air distribution; Attached air curtain; CFD; Turbulence models; Full-scale experimental validation; DISPLACEMENT VENTILATION; JET; COMFORT; SYSTEM;
D O I
10.1177/1420326X16655593
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a newly developed attached air curtain ventilation system. The airflow patterns produced by attached air curtain ventilation were modelled by computational fluid dynamic method. A full-scale experiment was conducted to determine the accuracy of four turbulence models: standard k-, RNG k-, SST k- and RSM-IP. SST k- model was shown to produce the most accurate results. The air distribution of attached air curtain ventilation within a full-scale enclosure could be predicted with an overall inaccuracy of 12%. All four models gave reasonably accurate prediction on air distribution for attached plane wall jet, but due to impingement in a corner, only RNG k- and SST k- models were shown to be reliable. The slot location could have a significant influence on simulation accuracy. When jet slot is close to sidewall, the numerical results of four models show good agreement with experimental data. The inaccuracy increases as s/b grows, but the maximum value appears in case of s/b=5, when airflow pattern of attached air curtain ventilation model has a combination characteristic of both mixing and displacement ventilation. In future studies, we should focus more on attached air curtain ventilation to provide a combination of mixing and displacement ventilation flow, which would provide useful application to different locations with wall-mounted terminals.
引用
收藏
页码:962 / 975
页数:14
相关论文
共 50 条
  • [1] Experimental and numerical study of a full scale ventilated enclosure:: Comparison of four two equations closure turbulence models
    Kuznik, Frederic
    Rusaouen, Gilles
    Brau, Jean
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1043 - 1053
  • [2] Airflow characteristics by air curtain jets in full-scale room
    尹海国
    李安桂
    [J]. Journal of Central South University, 2012, 19 (03) : 675 - 681
  • [3] Airflow characteristics by air curtain jets in full-scale room
    Hai-guo Yin
    An-gui Li
    [J]. Journal of Central South University, 2012, 19 : 675 - 681
  • [4] Airflow characteristics by air curtain jets in full-scale room
    Yin Hai-guo
    Li An-gui
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (03) : 675 - 681
  • [5] Experimental study of natural roof ventilation in full-scale enclosure fire tests in a small compartment
    Merci, Bart
    Vandevelde, Paul
    [J]. FIRE SAFETY JOURNAL, 2007, 42 (08) : 523 - 535
  • [6] A comparison of gas velocity measurements in a full-scale enclosure fire
    Bryant, Rodney A.
    [J]. FIRE SAFETY JOURNAL, 2009, 44 (05) : 793 - 800
  • [7] Numerical simulation of air flows in a full-scale ventilated room using different turbulence models
    Jiang, J. B.
    Wang, X.
    Zhang, Y.
    [J]. Livestock Environment VII, Proceedings, 2005, : 35 - 44
  • [8] Numerical simulations of full-scale enclosure fires in a small compartment with natural roof ventilation
    Merci, Bart
    Van Maele, Karim
    [J]. FIRE SAFETY JOURNAL, 2008, 43 (07) : 495 - 511
  • [9] An experimental study of full-scale open floor plan enclosure fires
    Hidalgo, J. P.
    Cowlard, A.
    Abecassis-Empis, C.
    Maluk, C.
    Majdalani, A. H.
    Kahrrnann, S.
    Hilditch, R.
    Krajcovic, M.
    Torero, J. L.
    [J]. FIRE SAFETY JOURNAL, 2017, 89 : 22 - 40
  • [10] Curtain Wall with Solar Preheating of Ventilation Air. Full Scale Experimental Assessment
    Garay-Martinez, Roberto
    Arregi, Benat
    [J]. 12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172