Accuracy of different impression techniques for multiunit implant restoration: A qualitative in vitro study

被引:0
|
作者
Ismail, Ibrahim Ahmed [1 ]
Alhajj, Mohammed Nasser [1 ,2 ]
机构
[1] Univ Khartoum, Fac Dent, Dept Oral Rehabil, Khartoum, Sudan
[2] Thamar Univ, Fac Dent, Dept Prosthodont, Dhamar, Yemen
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2020年 / 124卷 / 06期
关键词
PROSTHESES; PRECISION; TITANIUM; FIT; FRAMEWORKS;
D O I
10.1016/j.prosdent.2020.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Displacement of impression copings and/or implant replicas during impression making and dimensional changes that occur during clinical and laboratory phases of making multiunit implant prostheses may affect the accuracy and fit of the prostheses. Purpose. The purpose of this qualitative study was to investigate and compare 3 different impression techniques for osseointegrated dental implant transfer procedures. Material and methods. Three impression transfer approaches were evaluated and compared: closed-tray impression technique (CTT), impression with plastic snap-fit impression copings; open-tray impression technique (OTT), impression with independent square copings; and OTT joining the impression copings with a photo-polymerized resin (PPT). A reference acrylic resin model with 4 implants was fabricated. Polyvinyl siloxane with a stock tray was used to make 45 impressions (n=15 for each impression technique), and 45 die definitive stone casts. A computer-aided design and computer-aided manufacturing (CAD-CAM) titanium framework was fabricated on the reference model. Three blinded operators evaluated the fit of the CAD-CAM titanium framework on each model to find clinically acceptable fit. The Kappa test was used for the agreement between the examiners (alpha=.05). Results. Agreement was found among the 3 examiners on 44 of 45 specimens (Kappa value = 0.939; P<.001). In the CTT group, 14 casts were found to be acceptable. In the OTT group, nearly half of the specimens produced unacceptable fitting casts, whereas in the PPT group, 13 casts were found acceptable. Conclusions. CTT and PPT produced more accurate casts than the OTT technique, which yielded inferior results.
引用
收藏
页码:E1 / E5
页数:5
相关论文
共 50 条
  • [31] Accuracy of implant impression splinted techniques: Effect of splinting material
    Assif, D
    Nissan, J
    Varsano, I
    Singer, A
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (06) : 885 - 888
  • [32] A prospective clinical study on implant impression accuracy
    Motaz Osman
    Hassan Ziada
    Ahmed Suliman
    Neamat Hassan Abubakr
    [J]. International Journal of Implant Dentistry, 5
  • [33] Accuracy of impression and pouring techniques for an implant-supported prosthesis
    Del'Acqua, Marcelo Antonialli
    Arioli-Filho, Joao Neudenir
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (02) : 226 - 236
  • [34] Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations
    Moura, Renata Vasconcellos
    Kojima, Alberto Noriyuki
    Coury Saraceni, Cintia Helena
    Bassolli, Lucas
    Balducci, Ivan
    Ozcan, Mutlu
    Melo Mesquita, Alfredo Mikail
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E530 - E535
  • [35] A prospective clinical study on implant impression accuracy
    Osman, Motaz
    Ziada, Hassan
    Suliman, Ahmed
    Abubakr, Neamat Hassan
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2019, 5 (01)
  • [36] Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection
    Wenz, Hans-Juergen
    Hertrampf, Katrin
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (01) : 39 - 47
  • [37] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    [J]. JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 (06) : 412 - 415
  • [38] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    [J]. JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S412 - S415
  • [39] Accuracy of Different Elastomeric Impression Materials Using Dual Arch Impression Trays: An In Vitro Study
    Duseja, Sareen
    Shah, Dipti
    Vaishnav, Kalpesh
    Duseja, Shilpa
    Kumar, Santosh
    Desai, Khushboo
    [J]. ADVANCES IN HUMAN BIOLOGY, 2014, 4 (02) : 3 - 8
  • [40] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    [J]. JOURNAL OF DENTISTRY, 2024, 146