Measurement of Activated Au foils by 2πβ+2πβ-γ Coincidence Counting and EGS5 Monte Carlo Calculation

被引:0
|
作者
Sato, Yasushi [1 ]
Harano, Hideki
Matsumoto, Tetsuro
Nishiyama, Jun
Moriyama, Kentaro
Unno, Yasuhiro
Yamada, Takahiro
Yunoki, Akira
Hino, Yoshio
Kudo, Katsuhisa
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, 1-1-1 Umezono, Tsukuba, Ibaraki 3058568, Japan
关键词
activation analysis; coincidence counting; Monte Carlo; Au foil; EGS5;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
Neutron activation analysis using Au foil is a common and important method for measurement of thermal neutron fluence. To determine the activity of Au foil experimentally, Kawada et. al.([1]) proposed 2 pi beta+2 pi beta-gamma coincidence counting. This method is based on 4 pi beta-gamma coincidence counting but a 4 pi beta detector is divided into two 2 pi beta detectors those are independently operated in the method. In this research the correction factors in 2 pi beta+2 pi beta-gamma coincidence counting were obtained by measurement and simulation. The activities obtained by these correction factors were in good agreement.
引用
收藏
页码:907 / +
页数:2
相关论文
共 50 条
  • [1] Monte Carlo dose calculation for HDR brachytherapy source using EGS5 code
    Badry, H.
    Oufni, L.
    Ouabi, H.
    Hirayama, H.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2018, 150 : 76 - 81
  • [2] Calculation of coincidence summing in gamma-ray spectrometry with the EGS5 code
    Kajimoto, Tsuyoshi
    Endo, Satoru
    Nguyen Tat Thanh
    Shizuma, Kiyoshi
    [J]. APPLIED RADIATION AND ISOTOPES, 2015, 95 : 53 - 58
  • [3] Monte Carlo EGS5 Simulations of High PurityGermanium (HPGe) Detector
    Arif, Kamran
    Malik, Azhar H.
    [J]. 2015 POWER GENERATION SYSTEMS AND RENEWABLE ENERGY TECHNOLOGIES (PGSRET-2015), 2015, : 36 - 38
  • [4] ABSOLUTE MEASUREMENT OF ACTIVITY OF 198AU FOILS USING THE 4πβ-γ COINCIDENCE COUNTING METHOD AND CORRECTIONS BY THE MONTE CARLO SIMULATION
    Nishiyama, Jun
    Harano, Hideki
    Matsumoto, Tetsuro
    Sato, Yasushi
    Uritani, Akira
    Kudo, Katsuhisa
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 148 (02) : 237 - 241
  • [5] CALCULATION OF PERSONAL DOSE EQUIVALENT FOR POSITRON-EMITTING RADIONUCLIDES USING MONTE CARLO CODE EGS5
    Kato, T.
    Aoki, K.
    Yokoyama, S.
    Ejiri, K.
    Minami, K.
    Yashima, H.
    Taniguchi, A.
    Nakamura, T.
    Hirayama, H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 146 (1-3) : 202 - 205
  • [6] Simulation technique for extrapolation curves in 4πβ-γ coincidence counting method using EGS5 code
    Unno, Y.
    Sanami, T.
    Sasaki, S.
    Hagiwara, M.
    Yunoki, A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 109 : 363 - 368
  • [7] Evaluation of the electron transport algorithm in magnetic field in EGS5 Monte Carlo code
    Ito, Kengo
    Kadoya, Noriyuki
    Katsuta, Yoshiyuki
    Tanaka, Shohei
    Dobashi, Suguru
    Takeda, Ken
    Jingu, Keiichi
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 93 : 46 - 51
  • [8] Monte Carlo simulation of electron beams from medical linac using EGS5
    Nevelsky, A.
    Bar-Deroma, R.
    Orion, I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S138 - S139
  • [9] X-ray microbeam radiation therapy calculations, including polarisation effects, with the Monte Carlo code EGS5
    Hugtenburg, Richard P.
    Adegunloye, A. S.
    Bradley, David A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 221 - 224
  • [10] Absolute activity determination of 198Au solid source using 4πβ-γ coincidence counting corrected by Monte-Carlo calculation
    Mo, L.
    Wu, H. Y.
    Baldock, C.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (03) : 677 - 683