Simulation technique for extrapolation curves in 4πβ-γ coincidence counting method using EGS5 code

被引:2
|
作者
Unno, Y. [1 ]
Sanami, T. [2 ]
Sasaki, S. [2 ]
Hagiwara, M. [2 ]
Yunoki, A. [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, 1-1-1 Umezono, Tsukuba, Ibaraki 3058568, Japan
[2] High Energy Accelerator Res Org, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
关键词
Monte Carlo simulation; 4 pi beta-gamma coincidence method; Efficiency-extrapolation curve; Plastic scintillator;
D O I
10.1016/j.apradiso.2015.12.014
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A simulation technique was developed for the extrapolation technique in 4 pi beta-gamma coincidence counting method. Simultaneous emissions of beta and gamma rays were calculated using EGS5 code to obtain coincidence counting between both beta and gamma channels. The simulated extrapolation curves were compared with experimental data obtained with Cs-134 measurements using a plastic scintillator in the beta channel. The variation of the extrapolation curves with gamma-gate configuration was investigated by the simulation technique. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 368
页数:6
相关论文
共 31 条
  • [1] Calculation of coincidence summing in gamma-ray spectrometry with the EGS5 code
    Kajimoto, Tsuyoshi
    Endo, Satoru
    Nguyen Tat Thanh
    Shizuma, Kiyoshi
    [J]. APPLIED RADIATION AND ISOTOPES, 2015, 95 : 53 - 58
  • [2] Measurement of Activated Au foils by 2πβ+2πβ-γ Coincidence Counting and EGS5 Monte Carlo Calculation
    Sato, Yasushi
    Harano, Hideki
    Matsumoto, Tetsuro
    Nishiyama, Jun
    Moriyama, Kentaro
    Unno, Yasuhiro
    Yamada, Takahiro
    Yunoki, Akira
    Hino, Yoshio
    Kudo, Katsuhisa
    [J]. APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 907 - +
  • [3] Calculation of extrapolation curves in the 4π(LS)β-γ coincidence technique with the Monte Carlo code Geant4
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 109 : 319 - 324
  • [4] Monte Carlo dose calculation for HDR brachytherapy source using EGS5 code
    Badry, H.
    Oufni, L.
    Ouabi, H.
    Hirayama, H.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2018, 150 : 76 - 81
  • [5] Application of Monte Carlo simulation to the prediction of extrapolation curves in the coincidence technique
    Dias, Mauro S.
    Takeda, Mauro N.
    Koskinas, Marina F.
    [J]. APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1186 - 1192
  • [6] Monte Carlo simulation of electron beams from medical linac using EGS5
    Nevelsky, A.
    Bar-Deroma, R.
    Orion, I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S138 - S139
  • [7] CALCULATION OF PERSONAL DOSE EQUIVALENT FOR POSITRON-EMITTING RADIONUCLIDES USING MONTE CARLO CODE EGS5
    Kato, T.
    Aoki, K.
    Yokoyama, S.
    Ejiri, K.
    Minami, K.
    Yashima, H.
    Taniguchi, A.
    Nakamura, T.
    Hirayama, H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 146 (1-3) : 202 - 205
  • [8] CALCULATION OF EXTRAPOLATION CURVES IN THE 4-PI-BETA-GAMMA COINCIDENCE METHOD
    CHAUVENET, B
    BOUCHARD, J
    VATIN, R
    [J]. APPLIED RADIATION AND ISOTOPES, 1987, 38 (01) : 41 - 44
  • [9] Absolute activity of 133Ba by liquid scintillation coincidence counting using the 4π(e,X)-γ extrapolation technique
    Simpson, B. R. S.
    van Wyngaardt, W. M.
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 929 - 933
  • [10] Estimation of immediate fallout after the accident at Fukushima Daiichi Nuclear Power Plant by using HPGe detector and EGS5 code
    Unno, Yasuhiro
    Yunoki, Akira
    Sato, Yasushi
    Hino, Yoshio
    [J]. APPLIED RADIATION AND ISOTOPES, 2013, 81 : 348 - 352