Measurement of Activated Au foils by 2πβ+2πβ-γ Coincidence Counting and EGS5 Monte Carlo Calculation

被引:0
|
作者
Sato, Yasushi [1 ]
Harano, Hideki
Matsumoto, Tetsuro
Nishiyama, Jun
Moriyama, Kentaro
Unno, Yasuhiro
Yamada, Takahiro
Yunoki, Akira
Hino, Yoshio
Kudo, Katsuhisa
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, 1-1-1 Umezono, Tsukuba, Ibaraki 3058568, Japan
关键词
activation analysis; coincidence counting; Monte Carlo; Au foil; EGS5;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
Neutron activation analysis using Au foil is a common and important method for measurement of thermal neutron fluence. To determine the activity of Au foil experimentally, Kawada et. al.([1]) proposed 2 pi beta+2 pi beta-gamma coincidence counting. This method is based on 4 pi beta-gamma coincidence counting but a 4 pi beta detector is divided into two 2 pi beta detectors those are independently operated in the method. In this research the correction factors in 2 pi beta+2 pi beta-gamma coincidence counting were obtained by measurement and simulation. The activities obtained by these correction factors were in good agreement.
引用
收藏
页码:907 / +
页数:2
相关论文