Active Control of Transformer Noise by Using Power Line Signal as Reference

被引:0
|
作者
Das, Debi Prasad [1 ]
Moreau, Danielle J. [2 ]
Cazzolato, Ben S. [2 ]
机构
[1] CSIR Inst Minerals & Mat Technol, Bhubaneswar, Orissa, India
[2] Univ Adelaide, Sch Mech Engn, Adelaide, SA, Australia
关键词
Power transformer; transformer noise; active noise control; ALGORITHM; CANCELLATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The hum noise generated from the distribution transformers is annoying and is significant when the transformer is installed near the residential area. This hum noise consists of harmonics of 100 Hz, when the power line frequency is 50Hz. A new type of active noise control method has been proposed in this paper to combat such low-frequency harmonically related noise. The method is based on generation of required harmonics from the power line signal consisting of 50 Hz frequency using two adaptive filters. Through simulation study it has been shown that the proposed technique is able to accurately generate the mix of noise frequency components with the frequency change. The method also tracks the change in power line frequency and generates the corresponding anti-noise to nullify the noise.
引用
收藏
页码:953 / 956
页数:4
相关论文
共 50 条
  • [41] A waveform synthesis algorithm for active control of transformer noise: implementation
    Qiu, XJ
    Li, X
    Ai, YT
    Hansen, CH
    [J]. APPLIED ACOUSTICS, 2002, 63 (05) : 467 - 479
  • [42] An adaptive waveform synthesis algorithm for active control of transformer noise
    Qiu, XJ
    Hansen, CH
    [J]. PROCEEDINGS OF ACTIVE 99: THE INTERNATIONAL SYMPOSIUM ON ACTIVE CONTROL OF SOUND AND VIBRATION, VOLS 1 & 2, 1999, : 1057 - 1068
  • [43] A Modified Reference Signal Selection Method for Feed-Forward Active Road Noise Control System
    Zhou, Zhengdao
    Chen, Shuming
    Cai, Yaoyu
    Zhang, Zhang
    [J]. ACOUSTICS AUSTRALIA, 2023, 51 (02) : 243 - 253
  • [44] New concept of active control of transformer noise, Part 1: The active envelope
    L'Esperance, Andre
    Paillard, Bruno
    Boucher, Stephane
    Michaud, Philippe
    [J]. Canadian Acoustics - Acoustique Canadienne, 1998, 26 (03): : 8 - 9
  • [45] A Modified Reference Signal Selection Method for Feed-Forward Active Road Noise Control System
    Zhengdao Zhou
    Shuming Chen
    Yaoyu Cai
    Zhang Zhang
    [J]. Acoustics Australia, 2023, 51 : 243 - 253
  • [46] Reference signal generator for active power filters using improved adaptive predictive filter
    Han, BM
    Bae, BY
    Ovaska, SJ
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (02) : 576 - 584
  • [47] Reference Signal Generation For Shunt Active Power Filter Using Adaptive Filtering Approach
    Tamboli, Dipti A.
    Chile, R. H.
    [J]. 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, : 766 - 770
  • [48] Reference Generation Techniques for Active Power Line Conditioners
    Freijedo, Francisco D.
    Doval-Gandoy, Jesus
    Lopez, Oscar
    Cabaleiro, Jacobo
    [J]. IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 3054 - 3061
  • [49] Multiple reference active noise control - The attainable suppression
    Sujbert, Laszlo
    [J]. APPLIED ACOUSTICS, 2024, 217
  • [50] Power-line Energizing System for Active Power Electronic Current Transformer
    Chen, Jie
    Yan, Rongge
    Li, Jiayi
    Yang, Qingxin
    [J]. 2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1485 - 1488