Reference Signal Generation For Shunt Active Power Filter Using Adaptive Filtering Approach

被引:0
|
作者
Tamboli, Dipti A. [1 ]
Chile, R. H. [2 ]
机构
[1] SVERIs Coll Engn, Dept Elect & Telecommun Engn, Pandharpur 413304, India
[2] SGGS Inst Engn & Technol, Dept Elect Engn, Nanded 431606, India
关键词
Active Power Filters (APF); Adaptive Noise Cancellation (ANC); Recursive Least Square(RLS); Normalized Least Mean Square (NLMS);
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Power Quality issues are becoming a major concern for today's power system engineers. Large scale incorporation of non-linear loads has the potential to raise harmonic voltages and currents in an electrical distribution system to unacceptable high levels that can adversely affect the system. Active power filter (APF) based on power electronic technology is currently considered as the most competitive equipment for mitigation of harmonics and reactive power simultaneously. This paper deals with the noise cancellation which is one of the applications of adaptive filter in which different adaptive algorithms are used. Here two types of algorithms are used namely Normalized Least Mean Square (LMS) and Recursive Least Square (RLS) for harmonic noise cancelling. A SIMULINK model is developed using these algorithms. The results shown that the RLS algorithms present a better dynamic performance than NLMS in eliminating the total harmonic distortion (THD).
引用
收藏
页码:766 / 770
页数:5
相关论文
共 50 条
  • [1] Performance improvement of the shunt active power filter using a novel adaptive filtering approach
    Zoghbi, Abderrezzaq
    Berkani, Daoud
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2021, 29 (01) : 203 - +
  • [2] A PROPOSED REFERENCE CURRENT SIGNAL GENERATION TECHNIQUE FOR SHUNT ACTIVE POWER FILTER
    Nayak, B.
    Misra, B.
    Mohapatra, A.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 13 (06) : 1834 - 1849
  • [3] Research on Reference Signal of Shunt Active Power Filter
    Xu, Chengtao
    Chen, Long
    Cai, Shengnian
    Qin, Ran
    Pang, Baolin
    Sui, Liping
    2013 THIRD INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2013, : 1041 - 1044
  • [4] Fundamental Reference Signal Generation for Shunt Active Filter for Harmonic and Reactive Power Mitigation using Xilinx System Generator
    Sriranjani, R.
    Jayalalitha, S.
    2017 IEEE INTERNATIONAL CONFERENCE ON POWER, CONTROL, SIGNALS AND INSTRUMENTATION ENGINEERING (ICPCSI), 2017, : 2404 - 2410
  • [5] Adaptive Filter to Compute the Reference Current on Shunt Active Power Filters
    Petit, Johann F.
    Robles, Guillermo
    Amaris, Hortensia
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (06): : 2806 - 2815
  • [6] Model reference adaptive fuzzy control of a shunt active power filter
    Ma, Kaiqi
    Fei, Juntao
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2015, 28 (01) : 485 - 494
  • [7] Model Reference Adaptive Fuzzy Control of a Shunt Active Power Filter
    Ma, Kaiqi
    Fei, Juntao
    PROCEEDINGS OF THE 2014 9TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2014, : 655 - 660
  • [8] Comparative Study of Reference Current Generation for Shunt Active Power Filter
    Panchbhai, Anand
    Prajapati, Nikunj
    Parmar, Shreya
    2017 INTERNATIONAL CONFERENCE ON POWER AND EMBEDDED DRIVE CONTROL (ICPEDC), 2017, : 381 - 386
  • [9] Adaptive Transversal Digital Filter for Reference Current Detection in Shunt Active Power Filter
    Mohamed, A. A. S.
    Berzoy, Alberto
    Mohammed, Osama A.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [10] A single-phase DG generation unit with shunt active power filter capability by adaptive neural filtering
    Cirrincione, Maurizio
    Pucci, Marcello
    Vitale, Gianpaolo
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 2107 - +