Mechanical Feature Extraction of High Voltage Circuit Breaker based on Machine Vision

被引:1
|
作者
Yang, Dingge [1 ]
Niu, Bo [1 ]
Lei, Sheng [2 ]
Wang, Xueli [3 ]
Liu, Yakui [2 ]
Zhang, Guogang [2 ]
机构
[1] State Grid Shaanxi Elect Power Res Inst, Xian, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
[3] State Grid Xian New Area Power Supply Co, Xianyang, Peoples R China
关键词
high voltage circuit breaker; mechanical characteristics; machine vision; optical flow method; corner detection;
D O I
10.1109/ICEPE-ST51904.2022.9757125
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The contact displacement and speed curves are tightly linked to the performance of circuit breaker, which are key parameters of site test and widely used in the mechanical identification and prediction model of high voltage circuit breaker. In the traditional methods, acceleration or displacement sensors are installed on the insulated pull rod to measure the contact displacement. However, when the above methods are implemented at the site operation, the installation and disassembly of sensors greatly reduces the efficiency of mechanical characteristics test of the circuit breaker. In this paper, a mechanical feature extraction method for high voltage circuit breaker is proposed based on machine vision. Firstly, a high-speed camera is employed to record the video of the action process of spring operating mechanism, in which the insulated pull rods, crank arms, and many other critical parts are included. Secondly, the library function of computer vision OpenCV is used to read frame by frame and split the video into a time-lapse series of images and the optical flow method is applied to analyze the captured images to track the moving corner point and realize its feature extraction after the image preprocessing operation of filtering and noise reduction. Then, taking the point from the crank arm of operating mechanism as a corner, the angle displacement curve and angular speed curve of crank arm can be obtained. Finally, the contact displacement and other mechanical characteristics are calculated from the movement curve of crank arm, which could provide evidences for the condition assessment of high voltage circuit breaker. According to the non-contact measurement based on the machine vision, the adverse effects of mechanical sensors mounted inside circuit breaker could be avoided. Moreover, the proposed method provides a feasible way to evaluate the mechanical characteristics of a live circuit breaker in the field operating environment.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [41] Mechanical Condition Identification and Prediction of Spring Operating Mechanism of High Voltage Circuit Breaker
    Liu, Yakui
    Zhang, Guogang
    Zhao, Chenchen
    Lei, Sheng
    Qin, Hao
    Yang, Jinggang
    IEEE ACCESS, 2020, 8 : 210328 - 210338
  • [42] Mechanical fault diagnosis of high voltage circuit breaker using multimodal data fusion
    Li, Tianhui
    Xia, Yanwei
    Pang, Xianhai
    Zhu, Jihong
    Fan, Hui
    Zhen, Li
    Gu, Chaomin
    Dong, Chi
    Lu, Shijie
    PeerJ Computer Science, 2024, 10
  • [43] Sequential Mechanical Fault Diagnosis in High Voltage Circuit Breaker using Attention Mechanism
    Zhang, Baoyu
    Wang, Xinru
    Wang, Jin
    Journal of Physics: Conference Series, 2021, 2003 (01)
  • [44] A correction testing method for mechanical characteristic parameter of circuit breaker based on vision technology
    Zhao, Shutao
    Zhu, Jipeng
    Wu, Chengjian
    Wang, Bo
    He, Mengyuan
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 13 (08) : 1087 - 1091
  • [45] Detection of Mechanical Defects of High Voltage Circuit Breaker based on Improved Edge Detection and Deep Learning Algorithms
    Lei, Sheng
    Guo, Yibo
    Liu, Yakui
    Li, Feng
    Zhang, Guogang
    Yang, Dingge
    2022 6TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2022, : 372 - 375
  • [46] Research on Electrical and Mechanical Fault Diagnosis of High-Voltage Circuit Breaker Based on Multisensor Information Fusion
    Ma, Qinghua
    Dong, Ming
    Li, Qing
    Xing, Yadong
    Li, Yi
    Li, Qianyu
    Zhang, Lemeng
    2022 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP 2022), 2022, : 596 - 599
  • [47] Mechanical Fault Diagnosis Research of High Voltage Circuit Breaker Based on Kernel Principal Component Analysis and SoftMax
    Wang Y.
    Wu J.
    Ma S.
    Yang J.
    Zhao K.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 : 267 - 276
  • [48] Mechanical fault diagnosis of high voltage circuit breaker based on CEEMDAN sample entropy and FWA-SVM
    Zhao S.
    Ma L.
    Zhu J.
    Li J.
    Zhao H.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (03): : 181 - 186
  • [49] Fault feature extraction and classification of high voltage circuit breakers based on VMD and sample entropy
    Wan S.
    Dou L.
    Li C.
    Liu R.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2018, 37 (20): : 32 - 38
  • [50] Mechanical Life Prognosis of High Voltage Circuit Breakers Based on Support Vector Machine
    Zhang, Xin
    Huang, Ronghui
    Yao, Senjing
    Li, Gaoyang
    Zhong, Linlin
    Wang, Xiaohua
    2015 11TH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION (ICNC), 2015, : 749 - 753