Mechanical Feature Extraction of High Voltage Circuit Breaker based on Machine Vision

被引:1
|
作者
Yang, Dingge [1 ]
Niu, Bo [1 ]
Lei, Sheng [2 ]
Wang, Xueli [3 ]
Liu, Yakui [2 ]
Zhang, Guogang [2 ]
机构
[1] State Grid Shaanxi Elect Power Res Inst, Xian, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
[3] State Grid Xian New Area Power Supply Co, Xianyang, Peoples R China
关键词
high voltage circuit breaker; mechanical characteristics; machine vision; optical flow method; corner detection;
D O I
10.1109/ICEPE-ST51904.2022.9757125
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The contact displacement and speed curves are tightly linked to the performance of circuit breaker, which are key parameters of site test and widely used in the mechanical identification and prediction model of high voltage circuit breaker. In the traditional methods, acceleration or displacement sensors are installed on the insulated pull rod to measure the contact displacement. However, when the above methods are implemented at the site operation, the installation and disassembly of sensors greatly reduces the efficiency of mechanical characteristics test of the circuit breaker. In this paper, a mechanical feature extraction method for high voltage circuit breaker is proposed based on machine vision. Firstly, a high-speed camera is employed to record the video of the action process of spring operating mechanism, in which the insulated pull rods, crank arms, and many other critical parts are included. Secondly, the library function of computer vision OpenCV is used to read frame by frame and split the video into a time-lapse series of images and the optical flow method is applied to analyze the captured images to track the moving corner point and realize its feature extraction after the image preprocessing operation of filtering and noise reduction. Then, taking the point from the crank arm of operating mechanism as a corner, the angle displacement curve and angular speed curve of crank arm can be obtained. Finally, the contact displacement and other mechanical characteristics are calculated from the movement curve of crank arm, which could provide evidences for the condition assessment of high voltage circuit breaker. According to the non-contact measurement based on the machine vision, the adverse effects of mechanical sensors mounted inside circuit breaker could be avoided. Moreover, the proposed method provides a feasible way to evaluate the mechanical characteristics of a live circuit breaker in the field operating environment.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [31] High voltage circuit breaker acceptance testing
    Hartman, P
    NETA: Annual Technical Conference 2003: POWER SYSTEMS MAINTENANCE, 2003, : 229 - 236
  • [32] Timings of high voltage circuit-breaker
    Rusek, Bartosz
    Balzer, Gerd
    Holstein, Martin
    Claessens, Max-Steffen
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (12) : 2011 - 2016
  • [33] Vibration Signature Extraction of High-Voltage Circuit Breaker by Frequency and Chaotic Analysis
    Yang, Qiuyu
    Ruan, Jiangjun
    Zhuang, Zhijian
    Huang, Daochun
    Qiu, Zhibin
    IEEE ACCESS, 2019, 7 : 80884 - 80892
  • [34] Reliability Evaluation of High Voltage Circuit Breaker Based on IFAHP and GA
    Sun, Peng
    Jiang, Hongyun
    Yu, Hong
    Huang, Xuyong
    Sun, Yiyun
    Wang, Xin
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY AND ENVIRONMENTAL SCIENCE 2015, 2015, 31 : 1118 - 1121
  • [35] Research on combined diagnosis of mechanical fault vibration-sound signal of high voltage circuit breaker based on EEMD-Energy Entropy feature
    Zhang Yanfei
    Shao Yang
    Gong Weiwei
    Zhang Zhaowei
    Wu Jianwen
    INTERNATIONAL CONFERENCE ON SENSORS AND INSTRUMENTS (ICSI 2021), 2021, 11887
  • [36] Fault Diagnosis for High Voltage Circuit Breaker Based on Hilbert-Huang Transform and Support Vector Machine
    Hou, Chunguang
    Jia, Maoyuan
    Han, Ying
    Cao, Yundong
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 985 - 989
  • [37] Fxperimental Study of the Online Monitoring of the Mechanical Characteristics of a Hydraulic High Voltage Circuit Breaker
    Wang, Chengyou
    Liu, Candong
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 2706 - 2709
  • [38] Research and Design on On-line Monitoring of Mechanical Properties of High Voltage Circuit Breaker
    Song, Jiajia
    Zhang, Jinbo
    Chen, Bin
    Xiong, Zhengyong
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, ELECTRONIC, INDUSTRIAL AND CONTROL ENGINEERING, 2014, 5 : 110 - +
  • [39] Mechanical fault diagnosis of high voltage circuit breaker using multimodal data fusion
    Li, Tianhui
    Xia, Yanwei
    Pang, Xianhai
    Zhu, Jihong
    Fan, Hui
    Zhen, Li
    Gu, Chaomin
    Dong, Chi
    Lu, Shijie
    PEERJ COMPUTER SCIENCE, 2024, 10
  • [40] A New Method for Mechanical Fault Recognition of Extra-high Voltage Circuit Breaker
    Li, Dongyan
    Rong, Mingzhe
    Wang, Ting
    Wang, Xiaohua
    INTERNATIONAL CONFERENCE ON APPLIED PHYSICS AND INDUSTRIAL ENGINEERING 2012, PT A, 2012, 24 : 397 - 403