Optimization of Steam Governing Arrangement for 600MW Sub-critical Steam Turbine Unit

被引:0
|
作者
Guo, Di [1 ]
Hu, Nian-su [1 ]
Wang, Jian-mei [1 ]
Huang, Mei [1 ]
Liu, Yong-hui [2 ]
Yi, Zhao-hui [3 ]
机构
[1] Wuhan Univ, Sch Power & Mech Engn, Wuhan, Peoples R China
[2] Hunan Elect Power Test & Res Inst, Changsha, Hunan, Peoples R China
[3] State Nucl Power Design Res Inst, Beijing, Peoples R China
关键词
steam turbine; steam governing arrangement; regulation valve; steam governing performance;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Take a domestically-made imported 600MW sub-critical steam turbine unit as an example to carry on the research on steam governing performance of the regulation valve, get the bending stress ratio of the 1st stage blades and turbine's imbalance steam force by calculating, and then confirm the operating safety of the unit under different steam governing arrangements. Through the analysis of the calculation result, the optimization for a unit's steam governing arrangement is presented. The result of the calculation can offer the feasible theory and optimization basis for the valve's governing adjustment, provide some reference for the optimizing steam governing performance of other types of steam turbines.
引用
下载
收藏
页数:4
相关论文
共 50 条
  • [41] Simulation System on the Thermal Stress and Fatigue Life Loss of Startup and Shutdown for a Domestic 600MW Steam Turbo generator Unit
    Xia, Yunchun
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 818 - 823
  • [42] The optimization of the start-up scheduling for a 320 MW steam turbine
    Ji, Dong-Mei
    Sun, Jia-Qi
    Dui, Yue
    Ren, Jian-Xing
    ENERGY, 2017, 125 : 345 - 355
  • [43] Reconstruction of the gland sealing system of a 300MW steam turbine unit
    Xie, DM
    Liu, GL
    Wang, JM
    Yang, J
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 862 - 866
  • [44] Pressure Drop Optimization of the Main Steam and Reheat Steam System of a 1000 MW Secondary Reheat Unit
    Li, Yanfeng
    Liu, Jingru
    Huang, Guohe
    ENERGIES, 2022, 15 (09)
  • [45] EXPERIENCE OF COMMISSIONING THE 250-MW PROTOTYPE STEAM TURBINE-GAS TURBINE UNIT
    BOTVINOV, VP
    KIOR, GP
    GUSTI, IP
    SMOKOV, TI
    SIVART, AA
    YURASOV, AM
    THERMAL ENGINEERING, 1984, 31 (10) : 555 - 558
  • [46] Study on Control System of Turbine Speed of 600MW Ultra-Supercritical Unit
    Ding, Daye
    Yu, Shaojuan
    Li, Chen
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 660 - 664
  • [47] The vacuum system reform and test of the super-critical 600mw unit
    Yan, Tao
    Wan, Zhonghai
    Lu, Jin
    Chen, Wen
    Cai, Wen
    2017 3RD INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS SCIENCE (EEMS 2017), 2017, 94
  • [48] Research on material for ultra-super critical steam turbine unit
    Lu Zhiqiang
    Ju Fengming
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 270 - 274
  • [49] Coordinated Optimization of Multi Control System for Steam Turbine Generator Unit
    Xu, Yanhui
    Zhao, Shimeng
    Zhang, Sha
    10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 520 - 528
  • [50] DESIGN OF 500 MW SEMIPEAK-LOAD STEAM-TURBINE GENERATING UNIT
    KAPLUN, SM
    POPYRIN, LS
    CHERNETSKII, NS
    THERMAL ENGINEERING, 1975, 22 (05) : 11 - 16