Multichannel place pitch sensitivity in cochlear implant recipients

被引:22
|
作者
Laneau, J [1 ]
Wouters, J [1 ]
机构
[1] Katholieke Univ Leuven, Fac Med, Lab Expt ORL, B-3000 Louvain, Belgium
关键词
cochlear implant; place pitch; sensitivity; multichannel; monopolar;
D O I
10.1007/s10162-004-4049-y
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Cochlear implant recipients perceive a rise in pitch when the site of stimulation is moved from the apex toward the base. The place pitch sensitivity is typically measured using the stimulation of single channels. However, all current cochlear implant devices stimulate multiple channels simultaneously or with pulses temporally interleaved. The primary goal of the present study is to test whether the sensitivity of a cochlear implant recipient to changes in perceived pitch associated with changes of place of excitation improves or deteriorates when the number of active channels is increased, compared with stimulation with only one active channel. Place pitch sensitivity was recorded in four Nucleus CI24 subjects as a function of number of active channels (from 1 to 8). just noticeable differences were estimated from a constant stimuli 2AFC pitch-ranking experiment with roving loudness. Reference and comparison stimuli contained the same number of active channels but were shifted one or two electrodes toward the base or toward the apex. The place pitch sensitivity was measured using monopolar stimulation at two locations along the electrode array. To minimize cues related to loudness, the multichannel stimuli were loudness balanced relative to the single-channel stimuli presented at C-level. The number of active channels did not affect place pitch sensitivity. This is consistent with a model that compares the edges of the excitation pattern irrespective of the overlap between excitation patterns. There was a significant difference in sensitivity to place pitch among subjects. The average just noticeable differences of place pitch, extrapolated from a fitting procedure, for the subjects ranged from 0.25 mm to 0.46 mm.
引用
下载
收藏
页码:285 / 294
页数:10
相关论文
共 50 条
  • [1] Multichannel Place Pitch Sensitivity in Cochlear Implant Recipients
    Johan Laneau
    Jan Wouters
    Journal of the Association for Research in Otolaryngology, 2004, 5 : 285 - 294
  • [2] Relative importance of rate and place: Experiments using pitch scaling techniques with cochlear implant recipients
    Fearn, R
    Wolfe, J
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (12): : 51 - 53
  • [3] Place-Pitch Interval Perception With a Cochlear Implant
    Stupak, Natalia
    Todd, Ann E.
    Landsberger, David M.
    EAR AND HEARING, 2021, 42 (02): : 301 - 312
  • [4] Evaluation of the Optimized Pitch and Language Strategy in Cochlear Implant Recipients
    Vandali, Andrew
    Dawson, Pam
    Au, Agnes
    Yu, Yanyou
    Brown, Matthew
    Goorevich, Michael
    Cowan, Robert
    EAR AND HEARING, 2019, 40 (03): : 555 - 567
  • [5] PLACE-PITCH AND VOWEL-PITCH COMPARISONS IN COCHLEAR IMPLANT PATIENTS USING THE MELBOURNE-NUCLEUS COCHLEAR IMPLANT
    PAUKA, CK
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1989, : 1 - 31
  • [6] The role of intensity upon pitch perception in cochlear implant recipients
    Arnoldner, Christoph
    Kaider, Alexandra
    Hamzavi, Jafar
    LARYNGOSCOPE, 2006, 116 (10): : 1760 - 1765
  • [7] Place and Temporal Cues in Cochlear Implant Pitch and Melody Perception
    Swanson, Brett A.
    Marimuthu, Vijay
    Mannell, Robert H.
    FRONTIERS IN NEUROSCIENCE, 2019, 13
  • [8] The Impact of Age on Noise Sensitivity in Cochlear Implant Recipients
    Shew, Matthew A.
    Herzog, Jacques A.
    Kallogjeri, Dorina
    Chen, Stephanie
    Wick, Cameron
    Durakovic, Nedim
    McJunkin, Jonathan
    Buchman, Craig A.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (01) : 72 - 79
  • [9] SINGLE-CHANNEL TO MULTICHANNEL CONVERSIONS IN PEDIATRIC COCHLEAR IMPLANT RECIPIENTS
    MIYAMOTO, RT
    OSBERGER, MJ
    CUNNINGHAM, L
    KIRK, KI
    MYRES, WA
    ROBBINS, AM
    KESSLER, K
    AMERICAN JOURNAL OF OTOLOGY, 1994, 15 (01): : 40 - 45
  • [10] PITCH PERCEPTION IN PATIENTS WITH A MULTICHANNEL COCHLEAR IMPLANT USING VARIOUS PULSES WIDTH
    ARONSON, L
    ROSENHOUSE, J
    PODOSHIN, L
    ROSENHOUSE, G
    ZANUTTO, SB
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1994, 20 (1-2) : 43 - 51