Multichannel place pitch sensitivity in cochlear implant recipients

被引:22
|
作者
Laneau, J [1 ]
Wouters, J [1 ]
机构
[1] Katholieke Univ Leuven, Fac Med, Lab Expt ORL, B-3000 Louvain, Belgium
关键词
cochlear implant; place pitch; sensitivity; multichannel; monopolar;
D O I
10.1007/s10162-004-4049-y
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Cochlear implant recipients perceive a rise in pitch when the site of stimulation is moved from the apex toward the base. The place pitch sensitivity is typically measured using the stimulation of single channels. However, all current cochlear implant devices stimulate multiple channels simultaneously or with pulses temporally interleaved. The primary goal of the present study is to test whether the sensitivity of a cochlear implant recipient to changes in perceived pitch associated with changes of place of excitation improves or deteriorates when the number of active channels is increased, compared with stimulation with only one active channel. Place pitch sensitivity was recorded in four Nucleus CI24 subjects as a function of number of active channels (from 1 to 8). just noticeable differences were estimated from a constant stimuli 2AFC pitch-ranking experiment with roving loudness. Reference and comparison stimuli contained the same number of active channels but were shifted one or two electrodes toward the base or toward the apex. The place pitch sensitivity was measured using monopolar stimulation at two locations along the electrode array. To minimize cues related to loudness, the multichannel stimuli were loudness balanced relative to the single-channel stimuli presented at C-level. The number of active channels did not affect place pitch sensitivity. This is consistent with a model that compares the edges of the excitation pattern irrespective of the overlap between excitation patterns. There was a significant difference in sensitivity to place pitch among subjects. The average just noticeable differences of place pitch, extrapolated from a fitting procedure, for the subjects ranged from 0.25 mm to 0.46 mm.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 50 条
  • [31] Characterizing the relationship between modulation sensitivity and pitch resolution in cochlear implant users
    Camarena, Andres
    Goldsworthy, Raymond L.
    HEARING RESEARCH, 2024, 448
  • [32] Accuracy of cochlear implant recipients on pitch perception, melody recognition, and speech reception in noise
    Gfeller, Kate
    Turner, Christopher
    Oleson, Jacob
    Zhang, Xuyang
    Gantz, Bruce
    Froman, Rebecca
    Olszewski, Carol
    EAR AND HEARING, 2007, 28 (03): : 412 - 423
  • [33] The relation between electrophysiologic channel interaction and electrode pitch ranking in cochlear implant recipients
    Hughes, Michelle L.
    Abbas, Paul J.
    Journal of the Acoustical Society of America, 2006, 119 (03): : 1527 - 1537
  • [34] Pitch ranking ability of cochlear implant recipients: A comparison of sound-processing strategies
    Vandali, AE
    Sucher, C
    Tsang, DJ
    McKay, CM
    Chew, JWD
    McDermott, HJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 117 (05): : 3126 - 3138
  • [35] INDICATIONS AND RESULTS OF THE MULTICHANNEL COCHLEAR IMPLANT
    PIALOUX, P
    CHOUARD, CH
    MEYER, B
    FUGAIN, C
    ACTA OTO-LARYNGOLOGICA, 1979, 87 (3-4) : 185 - 189
  • [36] POSTOPERATIVE IMAGING OF THE MULTICHANNEL COCHLEAR IMPLANT
    SHPIZNER, BA
    HOLLIDAY, RA
    ROLAND, JT
    COHEN, NL
    WALTZMAN, SB
    SHAPIRO, WH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (07) : 1517 - 1524
  • [37] COCHLEAR IMPLANT FOR SIMULTANEOUS MULTICHANNEL STIMULATION
    MCDERMOTT, H
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1987, 96 (01): : 67 - 69
  • [38] ELECTRONIC DEVICE FOR MULTICHANNEL COCHLEAR IMPLANT
    CHOUARD, CH
    MACLEOD, P
    MEYER, B
    PIALOUX, P
    ANNALES D OTO-LARYNGOLOGIE ET DE CHIRURGIE CERVICO-FACIALE, 1977, 94 (7-8): : 353 - 363
  • [39] Effect of stimulus level and place of stimulation on temporal pitch perception by cochlear implant users
    Carlyon, Robert P.
    Lynch, Catherine
    Deeks, John M.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 127 (05): : 2997 - 3008
  • [40] Training of Cochlear Implant Users to Improve Pitch Perception in the Presence of Competing Place Cues
    Vandali, Andrew
    Sly, David
    Cowan, Robert
    van Hoesel, Richard
    EAR AND HEARING, 2015, 36 (02): : E1 - E13